High-performance liquid chromatographic analysis of verapamil and its application to determination in tablet dosage forms and to drug dissolution studies

被引:28
作者
Özkan, Y [1 ]
Yilmaz, N
Özkan, SA
Biryol, I
机构
[1] Gulhane Mil Med Acad, Dept Pharmaceut Technol, TR-06018 Ankara, Turkey
[2] Ankara Univ, Fac Pharm, Dept Analyt Chem, TR-06100 Ankara, Turkey
来源
FARMACO | 2000年 / 55卷 / 05期
关键词
verapamil hydrochloride; high-performance liquid chromatography; UV detector; fluorimetric detector; tablet analysis; dissolution profile;
D O I
10.1016/S0014-827X(00)00054-9
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A high-performance liquid chromatographic procedure with two detectors is presented for the determination of verapamil in pharmaceutical dosage forms. The procedure is based on the use of reversed-phase high-performance liquid chromatography with UV and fluorimetric detectors. Each analysis required no longer than 6 min for both detection procedures. Quantification was achieved by measurement of the ratio of the peak area of the drug to the internal standard (fluoxetine) and the detection limit was 10 ng/ml for the UV detector and 750 pg/ml for the fluorimetric detector. There was no significant difference between inter- and intra-day studies for verapamil determined for two different concentrations (0.05 and 1.00 mu g/ml). This process could be used to determine verapamil concentrations in the range 0.025-50 and 0.0008-20 mu g/ml for UV and fluorimetric detection, respectively. These methods were applied, without any interference from the excipients, for the determination of the drug in tablets and in drug dissolution studies. It is suggested that the proposed HPLC procedures could be used for routine quality control and dosage form assay of verapamil hydrochloride. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:376 / 382
页数:7
相关论文
共 20 条
[1]   Dissolution properties of flurazepam capsules [J].
Anchisi, C ;
Baroli, BM ;
Fadda, AM ;
Manconi, M ;
Sinico, C ;
Valenti, D .
FARMACO, 1998, 53 (10-11) :662-666
[2]   Automated determination of verapamil and norverapamil in human plasma with on-line coupling of dialysis to high-performance liquid chromatography and fluorometric detection [J].
Ceccato, A ;
Chiap, P ;
Hubert, P ;
Toussaint, B ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 750 (1-2) :351-360
[3]   CAPILLARY GAS-CHROMATOGRAPHIC DRUG SCREEN FOR USE IN FORENSIC TOXICOLOGY [J].
DRUMMER, OH ;
HOROMIDIS, S ;
KOURTIS, S ;
SYRJANEN, ML ;
TIPPETT, P .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (03) :134-138
[4]  
ELGHANY MFA, 1990, JPC-J PLANAR CHROMAT, V9, P388
[5]   Simultaneous determination of verapamil and norverapamil in biological samples by high-performance liquid chromatography using ultraviolet detection [J].
Garcia, MA ;
Aramayona, JJ ;
Bregante, MA ;
Fraile, LJ ;
Solans, C .
JOURNAL OF CHROMATOGRAPHY B, 1997, 693 (02) :377-382
[6]  
HARDMAN JG, 1996, GOODMAN GILMANS PHAR, P855
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF BASIC DRUGS ON SILICA COLUMNS USING NON-AQUEOUS IONIC ELUENTS .2. APPLICATION OF UV, FLUORESCENCE AND ELECTROCHEMICAL OXIDATION DETECTION [J].
JANE, I ;
MCKINNON, A ;
FLANAGAN, RJ .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (02) :191-225
[9]   VALIDATION OF AN IMPROVED WOODS ROTATING-DISK DISSOLUTION APPARATUS [J].
JASHNANI, RN ;
BYRON, PR ;
DALBY, RN .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1993, 82 (06) :670-671
[10]   PLASMA-LEVEL MONITORING OF D,L-VERAPAMIL AND 3 OF ITS METABOLITES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KOPPEL, C ;
WAGEMANN, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 570 (01) :229-234