Lung Nodule and Cancer Detection in Computed Tomography Screening

被引:95
作者
Rubin, Geoffrey D. [1 ]
机构
[1] Duke Clin Res Inst, Durham, NC 27705 USA
关键词
lung nodule; lung cancer; pulmonary nodule; computed tomography; image processing; eye tracking; computer-aided detection; SMALL PULMONARY NODULES; MAXIMUM-INTENSITY-PROJECTION; IMAGE-DATABASE-CONSORTIUM; LOW-DOSE CT; AIDED DETECTION; CHEST CT; RADIOLOGIST PERFORMANCE; MULTIDETECTOR CT; HELICAL CT; SCANS;
D O I
10.1097/RTI.0000000000000140
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fundamental to the diagnosis of lung cancer in computed tomography (CT) scans is the detection and interpretation of lung nodules. As the capabilities of CT scanners have advanced, higher levels of spatial resolution reveal tinier lung abnormalities. Not all detected lung nodules should be reported; however, radiologists strive to detect all nodules that might have relevance to cancer diagnosis. Although medium to large lung nodules are detected consistently, interreader agreement and reader sensitivity for lung nodule detection diminish substantially as the nodule size falls below 8 to 10 mm. The difficulty in establishing an absolute reference standard presents a challenge to the reliability of studies performed to evaluate lung nodule detection. In the interest of improving detection performance, investigators are using eye tracking to analyze the effectiveness with which radiologists search CT scans relative to their ability to recognize nodules within their search path in order to determine whether strategies might exist to improve performance across readers. Beyond the viewing of transverse CT reconstructions, image processing techniques such as thin-slab maximum-intensity projections are used to substantially improve reader performance. Finally, the development of computer-aided detection has continued to evolve with the expectation that one day it will serve routinely as a tireless partner to the radiologist to enhance detection performance without significant prolongation of the interpretive process. This review provides an introduction to the current understanding of these varied issues as we enter the era of widespread lung cancer screening.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 66 条
[21]   The National Lung Screening Trial: Overview and Study Design [J].
Gatsonis, Constantine A. .
RADIOLOGY, 2011, 258 (01) :243-253
[22]   Lung cancer: Interobserver agreement on interpretation of pulmonary findings at low-dose CT screening [J].
Gierada, David S. ;
Pilgram, Thomas K. ;
Ford, Melissa ;
Fagerstrom, Richard M. ;
Church, Timothy R. ;
Nath, Hrudaya ;
Garg, Kavita ;
Strollo, Diane C. .
RADIOLOGY, 2008, 246 (01) :265-272
[23]   Projected Outcomes Using Different Nodule Sizes to Define a Positive CT Lung Cancer Screening Examination [J].
Gierada, David S. ;
Pinsky, Paul ;
Nath, Hrudaya ;
Chiles, Caroline ;
Duan, Fenghai ;
Aberle, Denise R. .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2014, 106 (11)
[24]   Benefit of Computer-Aided Detection Analysis for the Detection of Subsolid and Solid Lung Nodules on Thin- and Thick-Section CT [J].
Godoy, Myrna C. B. ;
Kim, Tae Jung ;
White, Charles S. ;
Bogoni, Luca ;
de Groot, Patricia ;
Florin, Charles ;
Obuchowski, Nancy ;
Babb, James S. ;
Salganicoff, Marcos ;
Naidich, David P. ;
Anand, Vikram ;
Park, Sangmin ;
Vlahos, Ioannis ;
Ko, Jane P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (01) :74-83
[25]   Computer-coded diagnosis in lung nodule assessment [J].
Goldin, Jonathan G. ;
Brown, Matthew S. ;
Petkovska, Iva .
JOURNAL OF THORACIC IMAGING, 2008, 23 (02) :97-104
[26]   Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT [J].
Gruden, JF ;
Ouanounou, S ;
Tigges, S ;
Norris, SD ;
Klausner, TS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (01) :149-157
[27]  
Horeweg N, 2014, LANCET ONCOL
[28]   Automatic detection of subsolid pulmonary nodules in thoracic computed tomography images [J].
Jacobs, Colin ;
van Rikxoort, Eva M. ;
Twellmann, Thorsten ;
Scholten, Ernst Th. ;
de Jong, Pim A. ;
Kuhnigk, Jan-Martin ;
Oudkerk, Matthijs ;
de Koning, Harry J. ;
Prokop, Mathias ;
Schaefer-Prokop, Cornelia ;
van Ginneken, Bram .
MEDICAL IMAGE ANALYSIS, 2014, 18 (02) :374-384
[29]   Computer-Aided Nodule Detection and Volumetry to Reduce Variability Between Radiologists in the Interpretation of Lung Nodules at Low-Dose Screening Computed Tomography [J].
Jeon, Kyung Nyeo ;
Goo, Jin Mo ;
Lee, Chang Hyun ;
Lee, Youkyung ;
Choo, Ji Yung ;
Lee, Nyoung Keun ;
Shim, Mi-Suk ;
Lee, In Sun ;
Kim, Kwang Gi ;
Gierada, David S. ;
Bae, Kyongtae T. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (08) :457-461
[30]   Accuracy of 16-channel multi-detector row chest computed tomography with thin sections in the detection of metastatic pulmonary nodules [J].
Kang, Moon Chu ;
Kang, Chang Hyun ;
Lee, Hyun Ju ;
Goo, Jin Mo ;
Kim, Young Tae ;
Kim, Joo Hyun .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (03) :473-479