Comparison of myocardial T1 and T2 values in 3 T with T2*in 1.5 T in patients with iron overload and controls

被引:13
作者
Camargo, Gabriel C. [1 ,3 ]
Rothstein, Tamara [2 ]
Junqueira, Flavia P. [2 ,3 ]
Fernandes, Elsa [2 ]
Greiser, Andreas [4 ]
Strecker, Ralph [5 ]
Pessoa, Viviani [6 ]
Lima, Ronaldo S. L. [2 ,3 ]
Gottlieb, Ilan [1 ,7 ]
机构
[1] Casa de Saude Sao Jose, Rio De Janeiro, Brazil
[2] CDPI, Clin Diagnost Imagem, Rio De Janeiro, Brazil
[3] Univ Fed Rio de Janeiro, Hosp Univ Clementino Fraga Filho, Rio De Janeiro, Brazil
[4] Siemens AG, Healthcare Sect, Erlangen, Germany
[5] Siemens LTDA, Sao Paulo, Brazil
[6] Hemorio, State Inst Hematol, Rio De Janeiro, Brazil
[7] Natl Inst Cardiol, Rio De Janeiro, Brazil
关键词
Iron overload; Magnetic resonance; 3; Tesla; Parametric mapping; INVERSION-RECOVERY MOLLI; MAGNETIC-RESONANCE; THALASSEMIA MAJOR; IN-VIVO; RELAXATION; DIAGNOSIS; FERRITIN; FIBROSIS; MRI;
D O I
10.1007/s12185-016-1950-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial iron quantification remains limited to 1.5 T systems with T2* measurement. The present study aimed at comparing myocardial T2* values at 1.5 T to T1 and T2 mapping at 3.0 T in patients with iron overload and healthy controls. A total of 17 normal volunteers and seven patients with a history of myocardial iron overload were prospectively enrolled. Mid-interventricular septum T2*, native T1 and T2 times were quantified on the same day, using a multi-echo gradient-echo sequence at 1.5 T and T1 and T2 mapping sequences at 3.0 T, respectively. Subjects with myocardial iron overload (T2* < 20 ms) in comparison with those without had significantly lower mean myocardial T1 times (868.9 +/- A 120.2 vs. 1170.3 +/- A 25.0 ms P = 0.005 respectively) and T2 times (34.9 +/- A 4.7 vs. 45.1 +/- A 2.0 ms P = 0.007 respectively). 3 T T1 and T2 times strongly correlated with 1.5 T, T2* times (Pearson's r = 0.95 and 0.91 respectively). T1 and T2 measures presented less variability than T2* in inter- and intra-observer analysis. Native myocardial T1 and T2 times at 3 T correlate closely with T2* times at 1.5 T and may be useful for myocardial iron overload quantification.
引用
收藏
页码:530 / 536
页数:7
相关论文
共 40 条
[1]   Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload [J].
Anderson, LJ ;
Holden, S ;
Davis, B ;
Prescott, E ;
Charrier, CC ;
Bunce, NH ;
Firmin, DN ;
Wonke, B ;
Porter, J ;
Walker, JM ;
Pennell, DJ .
EUROPEAN HEART JOURNAL, 2001, 22 (23) :2171-2179
[2]  
[Anonymous], 2013, J CARDIOVASC MAGN R
[3]   Inherited disorders of iron metabolism [J].
Camaschella, Clara ;
Poggiali, Erika .
CURRENT OPINION IN PEDIATRICS, 2011, 23 (01) :14-20
[4]   On T2*Magnetic Resonance and Cardiac Iron [J].
Carpenter, John-Paul ;
He, Taigang ;
Kirk, Paul ;
Roughton, Michael ;
Anderson, Lisa J. ;
de Noronha, Sofia V. ;
Sheppard, Mary N. ;
Porter, John B. ;
Walker, J. Malcolm ;
Wood, John C. ;
Galanello, Renzo ;
Forni, Gianluca ;
Catani, Gualtiero ;
Matta, Gildo ;
Fucharoen, Suthat ;
Fleming, Adam ;
House, Michael J. ;
Black, Greg ;
Firmin, David N. ;
St Pierre, Timothy G. ;
Pennell, Dudley J. .
CIRCULATION, 2011, 123 (14) :1519-1528
[5]   Role of T2*Magnetic Resonance in Monitoring Iron Chelation Therapy [J].
Carpenter, John-Paul ;
Pennell, Dudley J. .
ACTA HAEMATOLOGICA, 2009, 122 (2-3) :146-154
[6]   Reduced Transverse Relaxation Rate (RR2) for Improved Sensitivity in Monitoring Myocardial Iron in Thalassemia [J].
Cheung, Jerry S. ;
Au, Wing-Yan ;
Ha, Shau-Yin ;
Kim, Daniel ;
Jensen, Jens H. ;
Zhou, Iris Y. ;
Cheung, Matthew M. ;
Wu, Yin ;
Guo, Hua ;
Khong, Pek-Lan ;
Brown, Truman R. ;
Brittenham, Gary M. ;
Wu, Ed X. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (06) :1510-1516
[7]  
Chow K, 2013, MAGN RESON MED, P1
[8]   MRI of cardiac iron overload [J].
Chu, Winnie C. W. ;
Au, Wing Y. ;
Lam, Wynnie W. M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) :1052-1059
[9]   In vivo comparison of myocardial T1 with T2 and T2*in thalassaemia major [J].
Feng, Yanqiu ;
He, Taigang ;
Carpenter, John-Paul ;
Jabbour, Andrew ;
Alam, Mohammed Harith ;
Gatehouse, Peter D. ;
Greiser, Andreas ;
Messroghli, Daniel ;
Firmin, David N. ;
Pennell, Dudley J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) :588-593
[10]   Myocardial T2 mapping with respiratory navigator and automatic nonrigid motion correction [J].
Giri, Shivraman ;
Shah, Saurabh ;
Xue, Hui ;
Chung, Yiu-Cho ;
Pennell, Michael L. ;
Guehring, Jens ;
Zuehlsdorff, Sven ;
Raman, Subha V. ;
Simonetti, Orlando P. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) :1570-1578