Effects of a partial pit ventilation system on indoor air quality and ammonia emission from a fattening pig room

被引:56
作者
Saha, Chayan Kumer [1 ]
Zhang, Guoqiang [1 ]
Kai, Peter [1 ]
Bjerg, Bjarne [2 ]
机构
[1] Univ Aarhus, Fac Agr Sci, Dept Agr Engn, DK-8830 Tjele, Denmark
[2] Univ Copenhagen, Fac Life Sci, Dept Large Anim Sci, DK-1870 Frederiksberg C, Denmark
关键词
MASS-TRANSFER COEFFICIENT; LIVESTOCK BUILDINGS; AQUEOUS-SOLUTIONS; SLATTED FLOORS; SCALE-MODEL; MANURE; FLOW; PATTERNS; BEHAVIOR; EUROPE;
D O I
10.1016/j.biosystemseng.2009.11.006
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The investigation was based on a hypothesis that applying an extra pit ventilation system may remove the highly concentrated gases and odours from the headspace above the liquid manure surface. This would improve air quality in the animal occupation zone, and utilising an air purification system to clean the pit-exhaust air may result in a reduction of the total emission from livestock buildings. In the investigations, an experimental fattening room with two pens and 30 pigs was used. The room was equipped with an automatically controlled negative pressure ventilation system with ceiling diffusion air inlet and a ceiling-roof top ventilator as a major exhaust unit. Additionally, an extra pit-exhaust unit was also installed. During the experiments, the major exhaust unit was automatically controlled by the climate computer according to indoor thermal conditions. About 10% of the maximum ventilation capacity was dedicated to the pit ventilation in each of two two-week periods. Ammonia concentrations, in air inlet and outlet, in the headspace above the slurry pit and in the slurry-pit exhaust were measured continuously. We found that the combination of ceiling and pit ventilation resulted in significantly lower ammonia concentrations in the room air (42.6%, p<0.001) and in the slurry-pit headspace (22.3%, p<0.001) compared with only ceiling ventilation. Total ammonia emissions increased slightly due to this new combination of ventilation systems. However, using an air cleaning system such as bioscrubber for pit exhaust, reductions in the ammonia emission of 37-53% from pig building might be achieved. The capacity required for the air cleaning needs only be 10% of the system capacity for cleaning all exhaust air. We conclude that indoor air quality can be significantly improved, and emission from the buildings significantly reduced, by utilising partial pit ventilation together with an exhaust air cleaning in pig buildings with ceiling ventilation system, without affecting pigs' behaviour. (C) 2009 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 22 条
[1]   Effect of slatted floor area on ammonia emission and on the excretory and lying behaviour of growing pigs [J].
Aarnink, AJA ;
vandenBerg, AJ ;
Keen, A ;
Hoeksma, P ;
Verstegen, MWA .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1996, 64 (04) :299-310
[2]   AMMONIA EMISSION PATTERNS DURING THE GROWING PERIODS OF PIGS HOUSED ON PARTIALLY SLATTED FLOORS [J].
AARNINK, AJA ;
KEEN, A ;
METZ, JHM ;
SPEELMAN, L ;
VERSTEGEN, MWA .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 62 (02) :105-116
[3]  
Aarnink AJA, 1997, T ASAE, V40, P1161, DOI 10.13031/2013.21337
[4]   Mass transfer coefficient of ammonia in liquid swine manure and aqueous solutions [J].
Arogo, J ;
Zhang, RH ;
Riskowski, GL ;
Christianson, LL ;
Day, DL .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 73 (01) :77-86
[5]  
Buiter JJ, 1998, T ASAE, V41, P1817, DOI 10.13031/2013.17335
[6]   Critical loads and the relevance of ammonia to an effects-based nitrogen Protocol [J].
Bull, KR ;
Sutton, MA .
ATMOSPHERIC ENVIRONMENT, 1998, 32 (03) :565-572
[7]   Assessment of human health risk due to inhalation exposure in cattle and pig farms in south Moravia [J].
Cupr, P ;
Skarek, M ;
Bartos, T ;
Cigánek, M ;
Holoubek, I .
ACTA VETERINARIA BRNO, 2005, 74 (02) :305-312
[8]  
DEPRAETERE K, 1990, J AGR ENG RES, V46, P31, DOI 10.1016/S0021-8634(05)80047-2
[10]  
GUSTAFSSON G, 1987, SEM 2 TECHN SECT CIG, P9