Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of free and total dabigatran in human plasma and its application to a pharmacokinetic study

被引:0
|
作者
Shaikh, Khurshid [1 ,2 ]
Mungantiwar, Ashish [1 ]
Halde, Supriya [1 ]
Pandita, Nancy [2 ]
机构
[1] Macleods Pharmaceut Ltd, Dept Bioequivalence, Res & Dev Ctr, Mumbai, Maharashtra, India
[2] NMIMS Univ, Sunandan Divatia Sch Sci, Dept Chem, Mumbai, Maharashtra, India
关键词
Anticoagulant; dabigatran; beta-glucuronide; LC-MS/MS; proton pump inhibitor; pharmacokinetics; DIRECT THROMBIN INHIBITOR; ORAL ANTICOAGULANTS; SIMULTANEOUS QUANTIFICATION; COAGULATION ASSAYS; UPLC-MS/MS; RIVAROXABAN; APIXABAN; VALIDATION; ETEXILATE; METABOLITE;
D O I
10.1080/03639045.2022.2069257
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A high-performance liquid chromatography-tandem mass spectrometric method for the determination of free and total dabigatran in human plasma has been developed and validated using a stable labeled internal standard (IS) as dabigatran D-4. The extraction of analyte arid IS was accomplished by the solidphase extraction technique. Chromatographic separations were achieved using Peerless basic C8 (150 x 4.6) mm, 5 mu column eluted at a flow rate of 1 mL/min with mobile phase Acetonitrile: 5mM ammonium formate: Methanol and 0.2% formic acid (30:20:50, v/v/v). The run time of the method was about 2.5 min with elution times of dabigatran and dabigatran D-4 at around 1.2 min. The multiple reaction monitoring transitions (Q(1)/Q(3)) were set at 472/289, 172 (m/z) for dabigatran, arid 476/293 (m/z) for dabigatran D-4. The calibration curves were linear (r(2) >= 0.99) over the range of 1.04-406.49 ng/mL. The presented method was successfully employed in the analysis of pharmacokinetic studies with the added advantage of demonstrating the effect of co-administration of dabigatran with the proton pump inhibitor pantoprazole on bioavailability and pharmacokinetic characteristics. Re-analysis of incurred sample resulted in >98% compliance indicating good assay precision of target analytes.
引用
收藏
页码:1835 / 1846
页数:12
相关论文
共 50 条
  • [31] An improved LC-MS/MS method for quantitative determination of ilaprazole and its metabolites in human plasma and its application to a pharmacokinetic study
    Zhou, Gan
    Tan, Zhi-rong
    Zhang, Wei
    Ou-Yang, Dong-sheng
    Chen, Yao
    Guo, Dong
    Liu, Ying-zi
    Fan, Lan
    Deng, Han-wu
    ACTA PHARMACOLOGICA SINICA, 2009, 30 (09) : 1330 - 1336
  • [32] An improved LC-MS/MS method for quantitative determination of ilaprazole and its metabolites in human plasma and its application to a pharmacokinetic study
    Gan Zhou
    Zhi-rong Tan
    Wei Zhang
    Dong-sheng Ou-Yang
    Yao Chen
    Dong Guo
    Ying-zi Liu
    Lan Fan
    Han-wu Deng
    Acta Pharmacologica Sinica, 2009, 30 : 1330 - 1336
  • [33] Determination of Tenacissoside A in rat plasma by liquid chromatography-tandem mass spectrometry method and its application to pharmacokinetic study
    Zhao, Luhua
    Xiang, Bingren
    Chen, Jing
    Tan, Xiying
    Wang, Dawei
    Chen, Daofeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1799 - 1804
  • [34] Determination and validation of psammaplin A and its derivatives in rat plasma by liquid chromatography-tandem mass spectrometry and its application in pharmacokinetic study
    Lee, Jae-Young
    Lee, Mee Yeon
    Ha, Min Woo
    Won, Tae Hyung
    Cho, Hyun-Jong
    Shin, Jongheon
    Park, Hyeung-geun
    Kim, Dae-Duk
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1000 : 155 - 162
  • [35] Sensitive liquid chromatography-tandem mass spectrometry method for the determination of scutellarin in human plasma: Application to a pharmacokinetic study
    Yulan, S
    Fang, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 830 (01): : 1 - 5
  • [36] An improved liquid chromatography tandem mass spectrometry (LC-MS/MS) method method for quantification of dexmedetomidine concentrations in samples of human plasma
    Moosavi, Seyed Mojtaba
    Shekar, Kiran
    Fraser, John F.
    Smith, Maree T.
    Ghassabian, Sussan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 : 118 - 122
  • [37] Validated liquid chromatography-tandem mass spectrometry method for quantitative determination of dauricine in human plasma and its application to pharmacokinetic study
    Liu, Xiaoying
    Liu, Qian
    Wang, Dongmei
    Wang, Xueya
    Zhang, Peng
    Xu, Haiyan
    Zhao, Hui
    Zhao, Huaiqing
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1199 - 1203
  • [38] The application of an LC-MS/MS method in a pharmacokinetic study for the determination of the concentration of nifekalant in human plasma
    Zhang, Mengmeng
    Shi, Guobing
    Sui, Yin
    An, Ye
    Yan, Ming
    Tang, Yunbiao
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 938 : 105 - 110
  • [39] Liquid chromatography-tandem mass spectrometry method development and validation for the determination of erlotinib in human plasma and its application in pharmacokinetic study
    Ramarao, N. T.
    Vidyadhara, S.
    Rao, M. V. Basaveswara
    Sasidhar, R. L. C.
    Yadav, R. Surendra
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (12) : 1488 - 1494
  • [40] Determination of Fusarium-mycotoxins beauvericin and enniatins with liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Jestoi, M
    Rokka, M
    Rizzo, A
    Peltonen, K
    Aurasaari, S
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (03) : 369 - 381