Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids

被引:31
|
作者
Frolov, S. V. [1 ]
Sindeev, S. V. [1 ]
Liepsch, D. [2 ]
Balasso, A. [3 ]
机构
[1] Tambov State Tech Univ, Dept Biomed Engn, Sovetskaya St 106, Tambov 392000, Russia
[2] Munich Univ Appl Sci, Dept Mech Engn, Munich, Germany
[3] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, D-80290 Munich, Germany
关键词
Hemodynamics; cerebral circulation; cardiovascular system; experimental set-up; laser doppler anemometer; flow visualization; mathematical model; aneurysm genesis; WALL SHEAR-STRESS; NUMERICAL-SIMULATION; THROMBUS FORMATION; BLOOD-FLOW; HEMODYNAMICS; ARTERY; GROWTH;
D O I
10.3233/THC-161132
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: According to the clinical data, flow conditions play a major role in the genesis of intracranial aneurysms. The disorder of the flow structure is the cause of damage of the inner layer of the vessel wall, which leads to the development of cerebral aneurysms. Knowledge of the alteration of the flow field in the aneurysm region is important for treatment. OBJECTIVE: The aim is to study quantitatively the flow structure in an patient-specific aneurysm model of the internal carotid artery using both experimental and computational fluid dynamics (CFD) methods with Newtonian and non-Newtonian fluids. METHODS: A patient-specific geometry of aneurysm of the internal carotid artery was used. Patient data was segmented and smoothed to obtain geometrical model. An elastic true-to-scale silicone model was created with stereolithography. For initial investigation of the blood flow, the flow was visualized by adding particles into the silicone model. The precise flow velocity measurements were done using 1D Laser Doppler Anemometer with a spatial resolution of 50 mu m and a temporal resolution of 1 ms. The local velocity measurements were done at a distance of 4 mm to each other. A fluid with non-Newtonian properties was used in the experiment. The CFD simulations for unsteady-state problem were done using constructed hexahedral mesh for Newtonian and non-Newtonian fluids. RESULTS: Using 1D laser Doppler Anemometer the minimum velocity magnitude at the end of systole -0.01 m/s was obtained in the aneurysm dome while the maximum velocity 1 m/s was at the center of the outlet segment. On central cross section of the aneurysm the maximum velocity value is only 20% of the average inlet velocity. The average velocity on the cross-section is only 11% of the inlet axial velocity. Using the CFD simulation the wall shear stresses for Newtonian and non-Newtonian fluid at the end of systolic phase (t = 0.25 s) were computed. The wall shear stress varies from 3.52 mPa (minimum value) to 10.21 Pa (maximum value) for the Newtonian fluid. For the non-Newtonian fluid the wall shear stress minimum is 2.94 mPa; the maximum is 9.14 Pa. The lowest value of the wall shear stress for both fluids was obtained at the dome of the aneurysm while the highest wall shear stress was at the beginning of the outlet segment. The vortex in the aneurysm region is unstable during the cardiac cycle. The clockwise rotation of the streamlines at the inlet segment for Newtonian and non-Newtonian fluid is shown. CONCLUSION: The results of the present study are in agreement with the hemodynamics theory of aneurysm genesis. Low value of wall shear stress is observed at the aneurysm dome which can cause a rupture of an aneurysm.
引用
收藏
页码:317 / 333
页数:17
相关论文
共 50 条
  • [21] Flow of two immiscible non-Newtonian fluids in an elastic tube
    Sreedharamalle, Sreenadh
    Baina, Sumalatha
    Srinivas, A. N. S.
    WORLD JOURNAL OF ENGINEERING, 2023, 20 (06) : 1174 - 1188
  • [22] MATHEMATICAL MODEL FOR NEWTONIAN AND NON-NEWTONIAN FLOW THROUGH TAPERED ARTERIES IN PRESENCE OF POROUS EFFECTS
    Kumar, Anil
    Verma, V. S.
    ADVANCES AND APPLICATIONS IN MATHEMATICAL SCIENCES, 2021, 20 (07): : 1329 - 1337
  • [23] The Quantification of Hemodynamic Parameters Downstream of a Gianturco Zenith Stent Wire Using Newtonian and Non-Newtonian Analog Fluids in a Pulsatile Flow Environment
    Walker, Andrew M.
    Johnston, Clifton R.
    Rival, David E.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (11):
  • [24] Numerical simulation of non-newtonian blood flow near a cerebrovascular branch with an aneurysm
    Department of Mechanical Engineering, Iwate University, 4-3-5 Ueda, Morioka-shi, Iwate, 020-8551, Japan
    Nihon Kikai Gakkai Ronbunshu, B, 2006, 1 (1-8): : 1 - 8
  • [25] Numerical Study of Purely Viscous Non-Newtonian Flow in an Abdominal Aortic Aneurysm
    Marrero, Victor L.
    Tichy, John A.
    Sahni, Onkar
    Jansen, Kenneth E.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (10):
  • [26] THEORETICAL AND EXPERIMENTAL STUDIES OF THE DEFORMATION OF BUBBLES MOVING IN QUIESCENT NEWTONIAN AND NON-NEWTONIAN LIQUIDS
    TSUKADA, T
    MIKAMI, H
    HOZAWA, M
    IMAISHI, N
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1990, 23 (02) : 192 - 198
  • [27] Modelling blood flow in coronary arteries: Newtonian or shear-thinning non-Newtonian rheology?
    De Nisco, Giuseppe
    Rizzini, Maurizio Lodi
    Verardi, Roberto
    Chiastra, Claudio
    Candreva, Alessandro
    De Ferrari, Gaetano
    D'Ascenzo, Fabrizio
    Gallo, Diego
    Morbiducci, Umberto
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 242
  • [28] CFD simulation of isolated bubbles rising in Newtonian or non-Newtonian fluids inside a thin-gap bubble column
    Almani, Sikandar
    Blel, Walid
    Gadoin, Emilie
    Gentric, Caroline
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2025, 214 : 202 - 218
  • [29] Cavitation Bubble Dynamics in Non-Newtonian Fluids
    Brujan, Emil-Alexandru
    POLYMER ENGINEERING AND SCIENCE, 2009, 49 (03) : 419 - 431
  • [30] Flow and mass transfer of fully resolved bubbles in non-Newtonian fluids
    Radl, Stefan
    Tryggvason, Gretar
    Khinast, Johannes G.
    AICHE JOURNAL, 2007, 53 (07) : 1861 - 1878