Measurements of the magnetocardiography in unshielded environment using high-Tc rf SQUID gradiometer

被引:3
|
作者
He, DF [1 ]
Zhang, F [1 ]
Xie, FX [1 ]
Dai, YD [1 ]
Wang, SG [1 ]
Ma, P [1 ]
Yang, T [1 ]
Wang, SZ [1 ]
Chen, WC [1 ]
Wang, ZQ [1 ]
机构
[1] Peking Univ, Dept Phys, Beijing 100871, Peoples R China
来源
PHYSICA C | 2000年 / 341卷
关键词
D O I
10.1016/S0921-4534(00)01429-5
中图分类号
O59 [应用物理学];
学科分类号
摘要
We recorded the 9-point magnetocardiography (MCG) of a normal person in an unshielded environment by using a first-order gradiometer made by subtracting the outputs of two high-T-c YBGO rf SQUID magnetometers. A compensation method was used to cancel the 50Hz line interference. After data processing and averaging, the fine structures of the heart signal (P-wave, Q,R,S-complex, T-wave) could be seen clearly and a SNR of 120 could be obtained.
引用
收藏
页码:2635 / 2636
页数:2
相关论文
共 50 条
  • [1] High-Tc SQUID gradiometer system for magnetocardiography in an unshielded environment
    Liao, SH
    Hsu, SC
    Lin, CC
    Horng, HE
    Chen, JC
    Chen, MJ
    Wu, CH
    Yang, HC
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (12): : 1426 - 1429
  • [2] Off-axis second-order high-TC rf SQUID gradiometer for magnetocardiography in unshielded environment
    Yang, HC
    Wang, SY
    Jeng, JT
    Chen, JH
    Horng, HE
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 360 - 363
  • [3] High-Tc SQUID gradiometers for magnetocardiography in an unshielded environment
    Tralshawala, N
    Claycomb, JR
    Ying, Q
    Miller, JH
    Nesteruk, K
    Jackson, DR
    BIOMAG 96: PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON BIOMAGNETISM, VOLS I & II, 2000, : 134 - +
  • [4] High-Tc second-order gradiometer for magnetocardiography in an unshielded environment
    Kouznetsov, KA
    Borgmann, J
    Clarke, J
    APPLIED PHYSICS LETTERS, 1999, 75 (13) : 1979 - 1981
  • [5] 2-HOLE BULK HIGH-TC SQUID ELECTRONIC GRADIOMETER FOR MAGNETOCARDIOGRAPHY IN UNSHIELDED SPACE
    TAVRIN, YA
    XU, Y
    BRAGINSKI, AI
    HEIDEN, C
    LINNIK, AS
    PAVLIUK, VA
    SCHAPOVALENKO, VV
    CRYOGENICS, 1993, 33 (07) : 719 - 723
  • [6] Development of a high-Tc magnetocardiography system for unshielded environment
    David, B.
    Doessel, O.
    Doormann, V.
    Eckart, R.
    Hoppe, W.
    Krueger, J.
    Laudan, H.
    Rabe, G.
    IEEE Transactions on Applied Superconductivity, 1997, 7 (2 pt 3): : 3267 - 3270
  • [7] High Tc SQUID Based Magnetocardiography System in Unshielded Environment
    Shanehsazzadeh, Faezeh
    Kalantari, Nafise
    Mohajeri, Roya
    Zandi, Hesam
    Yazdanian, Masoud
    Sarreshtedari, Farrokh
    Fardmanesh, Mehdi
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 1198 - 1202
  • [8] Achieving magnetocardiography map by using a single channel high Tc rf SQUID gradiometer
    Ma, P
    Yao, K
    Xie, FX
    Zhang, SY
    Deng, P
    He, DF
    Zhang, F
    Liu, LY
    Nie, RJ
    Wang, FR
    Wang, SZ
    Dai, YD
    ACTA PHYSICA SINICA, 2002, 51 (02) : 224 - 227
  • [9] Achieving magnetocardiography map by using a single channel high Tc rf SQUID gradiometer
    Ma, Ping
    Yao, Kun
    Xie, Fei-Xiang
    Zhang, Sheng-Yuan
    Deng, Peng
    He, Dong-Feng
    Zhang, Fan
    Liu, Le-Yuan
    Nie, Rui-Juan
    Wang, Fu-Ren
    Wang, Shou-Zheng
    Dai, Yuan-Dong
    Wuli Xuebao/Acta Physica Sinica, 2002, 51 (02): : 226 - 227
  • [10] Flip-chip-type high-Tc gradiometer for biomagnetic measurements in unshielded environment
    Yongjun Tian
    Tiansheng Wang
    Ke Chen
    Lie Chen
    Dongning Zheng
    Hanhong Qi
    Sven Linzen
    Frank Schmidl
    Paul Seidel
    Science in China Series A: Mathematics, 2000, 43 : 82 - 87