High-efficiency sample preparation with dimethylformamide for multi-element determination in pharmaceutical materials by ICP-AES

被引:27
|
作者
Tu, Qiang [1 ]
Wang, Tiebang [1 ]
Antonucci, Vincent [1 ]
机构
[1] Merck & Co Inc, Merck Res Labs, Rahway, NJ 07065 USA
关键词
Inductively coupled plasma-atomic emission spectrometry (ICP-AES); Metal analysis; Pharmaceutical; Sample preparation; Organic diluent; INDUCTIVELY-COUPLED PLASMA; ATOMIC EMISSION-SPECTROMETRY; MASS SPECTROMETRY; HEAVY-METALS; MS;
D O I
10.1016/j.jpba.2010.01.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The pressure to reduce cycle times of sample analysis has made it increasingly important to improve sample throughput during pharmaceutical process development. For ICP-based analyses, sample preparation is often the bottleneck of the entire analytical scheme due to the tedious digestion procedure and lacking a universal diluent for organic compounds. In this work, N,N-dimethylformamide (DMF) was used as a "universal" organic diluent so that the sample preparation can be simplified as a "dilute-and-shoot" procedure. An optimized interface with a commercial membrane desolvation unit was implemented, which enabled the introduction of organic solvents into an ICP-AES without organic loading. Mixed standard solutions of 15 elements (Al, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pd, Pt, Rh, Ru, W, Zn, and Zr), which covered the majority of processing metals routinely monitored in pharmaceutical development, were prepared for the study and stability of each element in a multi-element DMF solution was investigated. It was found that the addition of a stabilizing agent (EDTA) was necessary to ensure that all the elements at concentrations of 0.10-0.50 mu g/mL remained physically stable in solution (recovery better than 95%) for 2 weeks. It was also important to use an internal standard (yttrium) in order to compensate for signal drift and matrix effects from different sample matrices. A 2-10-fold increase of sensitivity (due to enhanced analyte transport efficiency) and acceptable levels of precision (RSD < 3%) and recoveries (91-111%) were achieved. The LOQs of all 15 elements were less than 10 mu g/L in the solution, which translates to less than 5 mu g/g or mu g/mL in pharmaceutical samples tested. This technique would minimize the effort required for sample preparation, thus reducing the cycle time by approximately 60-90% in the entire analytical scheme for samples that are difficult to be dissolved in nitric acid. This will provide opportunities for a new level of sample handling and automation for metal analysis in pharmaceutical process development. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:311 / 315
页数:5
相关论文
共 18 条
  • [11] Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
    Rantasa, Matjaz
    Majer, David
    Finsgar, Matjaz
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):
  • [12] A Fast Ultrasound-assisted Extraction Sample Preparation for Multi-elemental Determination of Contaminants in Pharmaceutical Ingredients by ICP-MS
    Moreno Aguiar, Giovanna de Fatima
    Batista, Bruno Lemos
    de Paula, Eloisa Silva
    Campiglia, Andres Dobal
    Barbosa, Fernando, Jr.
    ATOMIC SPECTROSCOPY, 2017, 38 (06) : 165 - 173
  • [13] Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser ablation
    Markus Tibi
    Klaus G. Heumann
    Analytical and Bioanalytical Chemistry, 2003, 377 : 126 - 131
  • [14] Multi-element Determination in Craft Chocolate with Different Cocoa Contents Using Ultrasound-Assisted Extraction and Dilute Acid as Sample Preparation
    Santana, Giovanna Fonseca Rosa
    Rodrigues, Romulo Silveira
    Brandao, Geisamanda Pedrini
    Costa, Vinicius Camara
    Carneiro, Maria Tereza Weitzel Dias
    FOOD ANALYTICAL METHODS, 2024, 17 (03) : 475 - 485
  • [15] Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser ablation
    Tibi, M
    Heumann, KG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 126 - 131
  • [16] Multi-element Determination in Craft Chocolate with Different Cocoa Contents Using Ultrasound-Assisted Extraction and Dilute Acid as Sample Preparation
    Giovanna Fonseca Rosa Santana
    Romulo Silveira Rodrigues
    Geisamanda Pedrini Brandão
    Vinicius Câmara Costa
    Maria Tereza Weitzel Dias Carneiro
    Food Analytical Methods, 2024, 17 : 475 - 485
  • [17] Multi-Element Determination of Trace Elements in Natural Water Reference Materials by ICP-SFMS after Tm Addition and Iron Co-precipitation
    Bayon, Germain
    Birot, Dominique
    Bollinger, Claire
    Barrat, Jean Alix
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2011, 35 (01) : 145 - 153
  • [18] Multi-Element Analysis Based on an Automated On-Line Microcolumn Separation/Preconcentration System Using a Novel Sol-Gel Thiocyanatopropyl-Functionalized Silica Sorbent Prior to ICP-AES for Environmental Water Samples
    Manousi, Natalia
    Kabir, Abuzar
    Furton, Kenneth G.
    Zachariadis, George A.
    Anthemidis, Aristidis
    MOLECULES, 2021, 26 (15):