Multi-frequency exciting and spectrogram-based ECT method

被引:24
|
作者
Chady, T
Enokizono, M
机构
[1] Oita Ind Res Inst, Mech & Elect Div, Oita 87011, Japan
[2] Oita Univ, Fac Engn, Oita 8701192, Japan
关键词
nondestructive testing; eddy-current methods; eddy-current sensors;
D O I
10.1016/S0304-8853(00)00263-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of this paper is to experimentally demonstrate advantages of a multi-frequency ECT system. In this system, a precise crack imaging was achieved by using spectrograms obtained from an eddy-current probe multifrequency response. A complex signal containing selected sinusoidal components was used as an excitation, The results of measurements for various test specimens are presented. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:700 / 703
页数:4
相关论文
共 50 条
  • [1] Flaws detection and characterization using the multi-frequency excitation and spectrogram ECT method
    Chady, T
    Enokizono, M
    Todaka, T
    Tsuchida, Y
    Sikora, R
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (IV), 2000, 17 : 87 - 94
  • [2] Multi-frequency ECT Method for Defect Depth Estimation
    Bernieri, Andrea
    Betta, Giovanni
    Ferrigno, Luigi
    Laracca, Marco
    2012 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2012), 2012, : 114 - 119
  • [3] Frequency scanning technology "Multi-Frequency excitation spectrogram method" for nondestructive evaluation
    Enokizono, M
    Chady, T
    APPLIED ELECTROMAGNETICS (III), 2001, 10 : 309 - 312
  • [4] Frequency scanning technique for nondestructive testing a multi-frequency excitation and spectrogram method
    Enokizono, M
    Chady, T
    Todaka, T
    Tsuchida, Y
    IECON 2000: 26TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4: 21ST CENTURY TECHNOLOGIES AND INDUSTRIAL OPPORTUNITIES, 2000, : 2513 - 2518
  • [5] Research on spectrogram method and flaw classification of multi-frequency eddy current
    College of Mechatronics Engineering and Automation, National University of Defense Technology, Changsha 410073, China
    Jixie Gongcheng Xuebao, 1600, 14 (24-28):
  • [6] Crack Depth Estimation by Using a Multi-Frequency ECT Method
    Bernieri, Andrea
    Betta, Giovanni
    Ferrigno, Luigi
    Laracca, Marco
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (03) : 544 - 552
  • [7] Multi-frequency ECT with AMR sensor
    He, D. F.
    Shiwa, M.
    Jia, J. P.
    Takatsubo, J.
    Moriya, S.
    NDT & E INTERNATIONAL, 2011, 44 (05) : 438 - 441
  • [8] A Spectrogram-Based Method of Rg Detection for Explosion Monitoring
    O'Rourke, Colin T.
    Baker, G. Eli
    BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 2017, 107 (01) : 34 - 42
  • [9] Numerical analysis of multi-frequency excitation spectrogram method for eddy current testing
    Tsuchida, Y
    Takahata, R
    Chady, T
    Enokizono, M
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 20A AND 20B, 2001, 557 : 627 - 634
  • [10] Spectrogram-based fundamental frequency tracking of spontaneous cries in preterm newborns
    Met-Montot, Bertille
    Cabon, Sandie
    Carrault, Guy
    Poree, Fabienne
    28TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2020), 2021, : 1185 - 1189