Biomechanical Comparison of Locking Plate and Cancellous Screw Techniques in Medial Malleolar Fractures: A Finite Element Analysis

被引:22
作者
Jiang, Dajun [1 ,2 ]
Zhan, Shi [1 ,2 ]
Wang, Qing [1 ]
Ling, Ming [1 ,2 ]
Hu, Hai [1 ,2 ]
Jia, Weitao [1 ]
机构
[1] Shanghai Jiaotong Univ Affiliated Peoples Hosp 6, Dept Orthoped Surg, Shanghai, Peoples R China
[2] Shanghai Jiaotong Univ Affiliated Peoples Hosp 6, Orthoped Biomech Lab, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
cannulated screws; finite element analysis; locking compression plate; medial malleolar fracture; VERTICAL SHEAR FRACTURES; INTERNAL-FIXATION; EPIDEMIOLOGY;
D O I
10.1053/j.jfas.2018.10.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
As the commonly used fixation strategy of medial malleolar fractures, cancellous screws (CS) have been challenged for instability, bone destruction, and metal prominence. It is still unclear whether a locking compression plate (LCP) is a better choice in such fractures. Our purpose is to compare the mechanical efficacy of LCP with traditional 4.0-mm CS for transverse, oblique, and vertical medial malleolar fractures by using finite element analysis. In this study, 3-dimensional models of the distal tibia were reconstructed from a computed tomography scan of a young healthy male adult. Conditions included 3 fracture lines at 30 degrees, 60 degrees, and 90 degrees; 2 groups of fixation (LCP and CS); and 3 adduction loads of 300, 500, and 700 N applied to the medial malleolar joint surface. The proximal part of the tibia was fixed for all degrees of freedom. The fracture displacements of the LCP were smaller than those of CS (p < .05). The stiffness of the LCP constructs was much higher than that of the CS constructs, especially in the 90 degrees fractures (490.3 versus 163.6 N/mm). The mean stress around the CS was higher than that in LCP for 60 degrees and 90 degrees fractures, but there was no difference for 30 degrees. Maximal bone stress increased (19.84 to 50.86 MPa) and concentrated on cortical bone in LCP, whereas it concentrated on cancellous bone in CS. The results showed that LCP could improve stability, preventing bone destruction in oblique and vertical medial malleolar fractures. However, in transverse fractures, CS provides sufficient stability, with no need to use LCP. (C) 2019 The Author(s). This is an open access article under the CC BY-NC-ND license. (http://creativecommons.org/licenses/by-nc-nd/4.0/)
引用
收藏
页码:1138 / 1144
页数:7
相关论文
共 25 条
[1]   Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes [J].
Anwar, Adeel ;
Lv, Decheng ;
Zhao, Zhi ;
Zhang, Zhen ;
Lu, Ming ;
Nazir, Muhammad Umar ;
Qasim, Wasim .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (04) :825-832
[2]   A clinical evaluation of alternative fixation techniques for medial malleolus fractures [J].
Barnes, Hayley ;
Cannada, Lisa K. ;
Watson, J. Tracy .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (09) :1365-1367
[3]   Evaluation of bone plate with low-stiffness material in terms of stress distribution [J].
Benli, Semih ;
Aksoy, Sami ;
Havitcioglu, Hasan ;
Kucuk, Mumin .
JOURNAL OF BIOMECHANICS, 2008, 41 (15) :3229-3235
[4]   Use of a Locked Fibular Plate for Fixation of a Vertical Shear Medial Malleolus Fracture: A Case Report [J].
Blake, Sean ;
Yakubek, George ;
Shaer, James .
JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (06) :1202-1205
[5]  
Christoph S., 2017, AO PRINCIPLES FRACTU, V3rd, P269
[6]   Epidemiology of adult fractures: A review [J].
Court-Brown, Charles M. ;
Caesar, Ben .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08) :691-697
[7]   EPIDEMIOLOGY OF ANKLE FRACTURES IN ROCHESTER, MINNESOTA [J].
DALY, PJ ;
FITZGERALD, RH ;
MELTON, LJ ;
ILSTRUP, DM .
ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (05) :539-544
[8]  
Dumigan RM, 2006, J ORTHOP TRAUMA, V20, P687, DOI 10.1097/01.bot.0000247075.17548.3a
[9]   A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests [J].
Eberle, S. ;
Gerber, C. ;
von Oldenburg, G. ;
Hoegel, F. ;
Augat, P. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H10) :1141-1152
[10]   The association between medial malleolar fracture geometry, injury mechanism, and syndesmotic disruption [J].
Ebraheim, Nabil A. ;
Weston, John T. ;
Ludwig, Todd ;
Moral, Muhammad Z. ;
Carroll, Trevor ;
Liu, Jiayong .
FOOT AND ANKLE SURGERY, 2014, 20 (04) :276-280