摘要
X-ray CT plays a great role both in medical fields and in industrial nondestructive tests. In imaging, metal objects absorb X-rays greatly, which introduces streaks on reconstructed images. In this paper, we propose a method for metal artifacts reduction. Firstly, the metal projection region is accurately identified and an interpolation method based on such identification is applied to get the projection data without metal. The image excluding metal is reconstructed from the modified projection data. Secondly, the image without metal is combined with the image of metal to form a complete reconstruction. Numerical simulations and a phantom experiment demonstrate that the metal artifacts can be effectively suppressed using our method and the reconstructed image is more accurate in depicting the details of cross-sections, especially in the immediate neighborhood of the metal object. The proposed method is computationally efficient and can be easily adapted to current commercial CT scanners.
引用
收藏
页码:11 / 19
页数:9
相关论文
共 10 条
[1]   A novel method for reducing high attenuation object artifacts in CT reconstructions [J].
Chen, LG ;
Liang, Y ;
Sandison, GA ;
Rydberg, J .
MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 :841-850
[2]   REPROJECTION USING A PARALLEL BACKPROJECTOR [J].
CRAWFORD, CR .
MEDICAL PHYSICS, 1986, 13 (04) :480-483
[3]  
GU J, 2004, P CT 3D IM C 2004 BE, V10, P12
[4]   REDUCTION OF CT ARTIFACTS CAUSED BY METALLIC IMPLANTS [J].
KALENDER, WA ;
HEBEL, R ;
EBERSBERGER, J .
RADIOLOGY, 1987, 164 (02) :576-577
[5]  
LEWITT RM, 1978, OPTIK, V50, P189
[6]  
Lin Z., 2001, J IMAGE GRAPH, V6, P142
[7]  
PETAL MB, 1983, J OPT SOC AM, V73, P1493
[8]   Iterative deblurring for CT metal artifact reduction [J].
Wang, G ;
Snyder, DL ;
OSullivan, JA ;
Vannier, MW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :657-664
[9]  
Xia Dan, 2005, Brachytherapy, V4, P18, DOI 10.1016/j.brachy.2004.11.001
[10]   X-ray CT metal artifact reduction using wavelets: Arm application for imaging total hip prostheses [J].
Zhao, SY ;
Roberston, DD ;
Wang, G ;
Whiting, B ;
Bae, KT .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (12) :1238-1247