Detection of Erosions in Sacroiliac Joints of Patients with Axial Spondyloarthritis Using the Magnetic Resonance Imaging Volumetric Interpolated Breath-hold Examination

被引:50
|
作者
Baraliakos, Xenofon [1 ]
Hoffmann, Florian [1 ]
Deng, Xiaohu [2 ]
Wang, Yan-Yan [2 ]
Huang, Feng [2 ]
Braun, Juergen [1 ]
机构
[1] Ruhr Univ Bochum, Rheumazentrum Ruhrgebiet, Claudiusstr 45, D-44649 Herne, Germany
[2] Chinese Peoples Liberat Army Gen Hosp, Dept Rheumatol, Beijing, Peoples R China
关键词
AXIAL SPONDYLOARTHRITIS; MAGNETIC RESONANCE IMAGING; COMPUTED TOMOGRAPHY; RADIOGRAPHS; SACROILIAC JOINTS; DIAGNOSIS; CRITERIA; MRI; CT;
D O I
10.3899/jrheum.181304
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective. The volumetric interpolated breath-hold examination (VIBE) magnetic resonance imaging (MRI) technique can visualize erosive cartilage defects in peripheral joints. We evaluated the ability of VIBE to detect erosions in sacroiliac joints (SIJ) of patients with axial spondyloarthritis (axSpA) compared to the established T1-weighted MRI sequence and computed tomography (CT). Methods. MRI (T1-weighted and VIBE) and CT scans of SIJ of 109 patients with axSpA were evaluated by 2 blinded readers based on SIJ quadrants (SQ). Erosions were defined according to Assessment of Spondyloarthritis international Society (ASAS) definitions. Scores were recorded if readers were in agreement. Results. Erosions were less frequently detected by CT (153 SQ) than by T1-weighted MRI (182 SQ; p = 0.008) and VIBE-MRI (199 SQ; p < 0.001 vs CT and p = 0.031 vs T1-weighted MRI). Taking CT as the gold standard, the sensitivity of VIBE-MRI (71.2%) was higher than that for T1-weighted MRI (63.4%), with similar specificity (87.3% vs 88%, respectively). In linear regression analysis, younger age was significantly associated with occurrence of erosions independently in VIBE-MRI (beta = 0.384, p < 0.001) and T1-weighted MRI (beta = 0.369, p < 0.001) compared to CT. Conclusion. The VIBE-MRI sequence was more sensitive than T1-weighted MRI in identifying erosive damage in the SIJ, especially in younger patients. This might be due to the ability of VIBE-MRI to identify structural changes in the cartilage that have not yet extended to the underlying bone, where CT seems to be superior.
引用
收藏
页码:1445 / 1449
页数:5
相关论文
共 50 条
  • [1] Interobserver Reliability of Magnetic Resonance Imaging of Sacroiliac Joints in Axial Spondyloarthritis
    Musetescu, Anca Emanuela
    Bobirca, Anca
    Gherghina, Florin Liviu
    Florescu, Alesandra
    Bobirca, Florin
    Ciurea, Paulina Lucia
    Criveanu, Cristina
    Musca, Alice
    Florescu, Lucian Mihai
    Gheonea, Ioana Andreea
    LIFE-BASEL, 2022, 12 (04):
  • [2] Magnetic Resonance Imaging Compared to Conventional Radiographs for Detection of Chronic Structural Changes in Sacroiliac Joints in Axial Spondyloarthritis
    Poddubnyy, Denis
    Gaydukova, Irma
    Hermann, Kay-Geert
    Song, In-Ho
    Haibel, Hildrun
    Braun, Juergen
    Sieper, Joachim
    JOURNAL OF RHEUMATOLOGY, 2013, 40 (09) : 1557 - 1565
  • [3] Hilar cholangiocarcinoma: preoperative evaluation with dimensional volumetric interpolated breath-hold examination magnetic resonance imaging sequence
    Yin Long-lin
    Song Bin
    Xu Juan
    Li Ying-chun
    CHINESE MEDICAL JOURNAL, 2007, 120 (08) : 636 - 642
  • [4] Hilar cholangiocarcinoma:preoperative evaluation with a three dimensional volumetric interpolated breath-hold examination magnetic resonance imaging sequence
    YIN Long-lin SONG Bin XU Juan LI Ying-chun Department of Radiology
    中华医学杂志(英文版), 2007, (08) : 636 - 642
  • [5] Prognostic Significance of Magnetic Resonance Imaging Changes of the Sacroiliac Joints in Spondyloarthritis - A Followup Study
    Madsen, Karen Berenth
    Schiottz-Christensen, Berit
    Jurik, Anne Grethe
    JOURNAL OF RHEUMATOLOGY, 2010, 37 (08) : 1718 - 1727
  • [6] The comparison of direct magnetic resonance arthrography with volumetric interpolated breath-hold examination sequence and multidetector computed tomography arthrography techniques in detection of talar osteochondral lesions
    Pirimoglu, Berhan
    Ogul, Hayri
    Polat, Gokhan
    Kantarci, Mecit
    Levent, Akin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2019, 53 (03) : 209 - 214
  • [7] Mandibular canal visibility using a plain volumetric interpolated breath-hold examination sequence in MRI
    Deepho, Chutamas
    Watanabe, Hiroshi
    Sakamoto, Junichiro
    Kurabayashi, Tohru
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (01)
  • [8] Flip Angle for the Optimal T1-weighted Image in the 3-D Volumetric Interpolated Breath-hold Examination Abdominal Magnetic Resonance Imaging Technique
    Goo, Eun-Hoe
    Kweon, Dae Cheol
    Dong, Kyung-Rae
    Lee, Jae-Seung
    Chung, Woon-Kwan
    Choi, Jiwon
    Lee, Jong-Woong
    Choe, Chong-Hwan
    APPLIED MAGNETIC RESONANCE, 2011, 40 (02) : 221 - 229
  • [9] Fat-suppressed dynamic and delayed gadolinium-enhanced volumetric interpolated breath-hold magnetic resonance Imaging of cholangiocarcinoma
    Leyendecker, John R.
    Gakhal, Mandip
    Elsayes, Khaled M.
    McDermott, Ronan
    Narra, Vamsidhar R.
    Brown, Jeffrey J.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (02) : 178 - 184
  • [10] Artificial intelligence for the detection of sacroiliitis on magnetic resonance imaging in patients with axial spondyloarthritis
    Lee, Seulkee
    Jeon, Uju
    Lee, Ji Hyun
    Kang, Seonyoung
    Kim, Hyungjin
    Lee, Jaejoon
    Chung, Myung Jin
    Cha, Hoon-Suk
    FRONTIERS IN IMMUNOLOGY, 2023, 14