Short poly(ethylene glycol) block initiation of poly(L-lactide) di-block copolymers: a strategy for tuning the degradation of resorbable devices

被引:8
作者
Azhari, Zein [1 ]
McMahon, Sean [2 ,3 ]
Pierucci, Luca [2 ]
Wang, Wenxin [2 ,3 ]
Cameron, Ruth E. [1 ]
机构
[1] Univ Cambridge, Dept Mat Sci & Met, Cambridge, England
[2] Vornia Biomat Ltd, Tallaght, Synergy Ctr, Dublin, Ireland
[3] Univ Coll Dublin, Charles Inst Dermatol, Sch Med & Med Sci, Dublin, Ireland
基金
英国工程与自然科学研究理事会;
关键词
polymer degradation; processing; hydrolysis; characterisation; bioresorbable; biomaterials; POLY-L-LACTIDE; THERMAL CHARACTERIZATION; MOLECULAR-WEIGHT; POLYLACTIDES; FILMS; ACID);
D O I
10.1002/pi.5563
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
The current range of medical applications of resorbable polyesters could be hugely expanded if more effective strategies for tailoring degradation rate were available. Block copolymerisation with poly(ethylene glycol) (PEG) has been shown to reduce degradation times; however, to date, this has relied on the addition of PEG to short lengths of polyester. This results in copolymers with high fractions of PEG and low molecular weights, reducing the potential range of applications. Furthermore, there has been no systematic study of the relative lengths of the blocks. In this work, we employed short hydroxyl-functionalised methoxy-terminated mPEG to initiate the synthesis of poly(L-lactide) (PLLA), resulting in controlled di-block copolymers with short mPEG blocks and long PLLA blocks. A controlled series of polymers was made with PLLA lengths (60 < M-n (kg mol(-1)) < 200) and mPEG lengths (550 < M-n (g mol(-1)) < 5000) giving very low mPEG content (0.1-1.5 wt%). We found that, despite the low fraction of mPEG, water uptake and the rate of hydrolytic degradation, k, increased. Significantly, k for the polymers was dependent only on the presence of mPEG, and was little affected by mPEG length or PLLA length in the ranges studied. Moreover, mass loss began in all polymers when Mn of the polymer fell below a threshold of about 20 kg mol(-1) and depended on both the initial molecular weight of PLLA and the presence (but not the length) of mPEG. Short-chain mPEG therefore provides a new route for targeted, temporal control of resorbable polyesters for biomedical devices. (C) 2018 The Authors. Polymer International published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
引用
收藏
页码:726 / 738
页数:13
相关论文
共 32 条
[1]  
Cameron RE, 2003, DURABILITY RELIABILI, P96
[2]  
Campos CAM, 2013, J INTERV CARDIOL, V5, P639
[3]   BLOCK-COPOLYMERS OF L-LACTIDE AND POLY(ETHYLENE GLYCOL) FOR BIOMEDICAL APPLICATIONS [J].
CERRAI, P ;
TRICOLI, M ;
LELLI, L ;
GUERRA, GD ;
DELGUERRA, RS ;
CASCONE, MG ;
GIUSTI, P .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) :308-313
[4]   PROTON NMR CHARACTERIZATION OF POLY(ETHYLENE GLYCOLS) AND DERIVATIVES [J].
DUST, JM ;
FANG, ZH ;
HARRIS, JM .
MACROMOLECULES, 1990, 23 (16) :3742-3746
[5]   Degradation Properties of Co-Continuous Calcium-Phosphate-Polyester Composites [J].
Ehrenfried, Lisa M. ;
Farrar, David ;
Cameron, Ruth E. .
BIOMACROMOLECULES, 2009, 10 (07) :1976-1985
[6]   THE EFFECT OF MELT-PROCESSING ON THE DEGRADATION OF SELECTED POLYHYDROXYACIDS - POLYLACTIDES, POLYHYDROXYBUTYRATE, AND POLYHYDROXYBUTYRATE-CO-VALERATES [J].
GOGOLEWSKI, S ;
JOVANOVIC, M ;
PERREN, SM ;
DILLON, JG ;
HUGHES, MK .
POLYMER DEGRADATION AND STABILITY, 1993, 40 (03) :313-322
[7]  
Henry D, 2009, MAT COATINGS MED DEV, P225
[8]  
HU DSG, 1993, POLYM BULL, V30, P669
[9]   STRUCTURAL-ANALYSIS AND DEGRADATION BEHAVIOR IN POLYETHYLENE-GLYCOL POLY (L-LACTIDE) COPOLYMERS [J].
HU, DSG ;
LIU, HJ .
JOURNAL OF APPLIED POLYMER SCIENCE, 1994, 51 (03) :473-482
[10]   THERMAL CHARACTERIZATION OF POLYLACTIDES [J].
JAMSHIDI, K ;
HYON, SH ;
IKADA, Y .
POLYMER, 1988, 29 (12) :2229-2234