Cerebral aneurysms diagnosis by three-dimensional CT angiography

被引:4
|
作者
de Andrade, GC [1 ]
Teixeira, PAD [1 ]
Alves, HFP [1 ]
Donato, EE [1 ]
Moreira, CAA [1 ]
de Faria, RCS [1 ]
Dias, LAA [1 ]
机构
[1] Neurorradiol Santa Casa Ribeirao Preto, Serv Neurocirurg, Ribeirao Preto, Brazil
关键词
cerebral aneurysm; computerized three-dimensional; angiotomography;
D O I
10.1590/S0004-282X2003000100013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Three-dimensional computerized tomography angiography is a fast diagnosis method and low invasive that passed to be used recently in the cases of intracranial aneurysms. This method presents a 100% specificity and can reach 95% of sensibility in the evaluation of the aneurysms in the circle of Willis, substituting the digital angiography but not in all of the cases. We report our experience in evaluation of the three-dimensional angiotomography exams in a period of 2 years between June of 1997 and June of 1999, were accomplished for detection of intracranial aneurysms in 136 patients, being 118 just with three-dimensional angiotomography and in 18 cases they were accomplished besides three-dimensional angiotomography also the conventional digital angiography. The exam of three-dimensional angiotomography possesses low risk being used better in the detection of the aneurysms when possess higher diameter than 3 mm, with some limitations as. in the very small aneurysms when smaller than 3 mm, carotid intern cavarnous aneurysms, posterior circulation aneurysms as well as the non accomplishment of the dynamic exam.
引用
收藏
页码:74 / 78
页数:5
相关论文
共 50 条
  • [1] Cerebral aneurysms: Evaluation with three-dimensional CT angiography
    Ogawa, T
    Okudera, T
    Noguchi, K
    Sasaki, N
    Inugami, A
    Uemura, K
    Yasui, N
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (03) : 447 - 454
  • [2] Three-dimensional rotational angiography in the diagnosis of cerebral aneurysms
    Capello, D
    Mavilio, N
    Allegretti, L
    Rosa, ML
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 : 45 - 50
  • [3] The limitations of three-dimensional CT angiography (3D-CTA) in the diagnosis of cerebral aneurysms
    Yasui, T
    Kishi, H
    Komiyama, M
    Iwai, Y
    Yamanaka, K
    Nishikawa, M
    Nakajima, H
    Morikawa, T
    NEUROLOGICAL SURGERY, 2000, 28 (11): : 975 - 981
  • [4] Three-dimensional electron beam CT angiography in the diagnosis of intracranial aneurysms
    Chen, S
    Shen, TZ
    Chen, XR
    CHINESE MEDICAL JOURNAL, 1999, 112 (08) : 739 - 742
  • [5] Sub-millimeter three-dimensional CT angiography in the detection of cerebral aneurysms
    Katada, K
    Hayakawa, M
    Takeshita, G
    Ogura, Y
    Kato, R
    Koga, S
    RADIOLOGY, 1998, 209P : 156 - 156
  • [6] The three-dimensional CT angiography findings of ruptured aneurysms hardly detectible by repeated cerebral angiography
    Takabatake, Y
    Uno, E
    Wakamatsu, K
    Okada, Y
    Kaneko, T
    Tsuchiya, Y
    Miyayama, S
    NEUROLOGICAL SURGERY, 2000, 28 (03): : 237 - 243
  • [7] Effects of three-dimensional angiography on the coiling of cerebral aneurysms
    Albuquerque, FC
    Spetzler, RF
    Zabramski, JM
    McDougall, CG
    NEUROSURGERY, 2002, 51 (03) : 597 - 605
  • [8] Depicting cerebral veins by three-dimensional CT angiography before surgical clipping of aneurysms
    Kaminogo, M
    Hayashi, H
    Ishimaru, H
    Morikawa, M
    Kitagawa, N
    Matsuo, Y
    Hayashi, K
    Yoshioka, T
    Shibata, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (01) : 85 - 91
  • [9] Application of three-dimensional CT angiography (3D-CTA) to cerebral aneurysms
    Kato, Y
    Sano, H
    Katada, K
    Ogura, Y
    Hayakawa, M
    Kanaoka, N
    Kanno, T
    SURGICAL NEUROLOGY, 1999, 52 (02): : 113 - 121
  • [10] Diagnosis of unruptured cerebral aneurysms using magnetic resonance angiography and three-dimensional computed tomographic angiography
    Okuyama, T
    Saito, K
    Hirano, A
    Takahashi, A
    Hashimoto, Y
    Inagaki, T
    NEUROLOGICAL SURGERY, 1997, 25 (12): : 1073 - 1079