A new locking plate for unstable fractures of the proximal humerus

被引:225
作者
Fankhauser, F [1 ]
Boldin, C [1 ]
Schippinger, G [1 ]
Haunschmid, C [1 ]
Szyszkowitz, R [1 ]
机构
[1] Graz Univ, Med Ctr Graz, Dept Traumatol, A-8036 Graz, Austria
关键词
D O I
10.1097/01.blo.0000137554.91189.a9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In a prospective study, 28 patients with 29 proximal humeral fractures were treated with the Locking Proximal Humerus Plate from 2001-2002. Most of these fractures were complex, Type B (n = 15) and Type C (n = 9) fractures, according to the AO classification. Followups included radiographs, clinical examinations, and recording Constant scores. After 1 year, the average Constant score for all fractures was 74.6 (range, 37-96). For Type A fractures, it was 82.6 (range, 60-96), for Type B it was 78.3 (range, 37-95), and for Type C it was 64.6 (range, 40-91). Complications related to the implant included breakage of the plate in one patient and redislocation of the fracture in four patients (one fracture was associated with deep infection), which required reoperation in two patients. Partial osteonecrosis was seen in two patients, once after deep infection. There were no nonunions. Our data show that using the Locking Proximal Humerus Plate for treatment of proximal humeral fractures of all types is a reliable procedure, with good results being obtained with careful planning and familiarity with the special features of the operative technique.
引用
收藏
页码:176 / 181
页数:6
相关论文
共 27 条
[1]   VASCULARITY OF THE HUMERAL HEAD AFTER PROXIMAL HUMERAL FRACTURES - AN ANATOMICAL CADAVER STUDY [J].
BROOKS, CH ;
REVELL, WJ ;
HEATLEY, FW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01) :132-136
[2]  
CONSTANT CR, 1987, CLIN ORTHOP RELAT R, P160
[3]  
Cornell C N, 1994, Orthop Rev, VSuppl, P19
[4]   A new internal fixation technique for fractures of the proximal humerus - the Bilboquet device: A report on 26 cases [J].
Doursounian, L ;
Grimberg, J ;
Cazeau, C ;
Jos, E ;
Touzard, RC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2000, 9 (04) :279-288
[5]   Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3) [J].
Fankhauser, F ;
Schippinger, G ;
Weber, K ;
Heinz, S ;
Quehenberger, F ;
Boldin, C ;
Bratschitsch, G ;
Szyszkowitz, R ;
Georg, L ;
Friedrich, A .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 55 (02) :345-349
[6]  
Frigg R, 2001, Injury, V32 Suppl 2, P63, DOI 10.1016/S0020-1383(01)00127-9
[7]   The clinical relevance of posttraumatic avascular necrosis of the humeral head [J].
Gerber, C ;
Hersche, O ;
Berberat, C .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (06) :586-590
[8]  
Gicquel P, 1999, REV CHIR ORTHOP, V85, P811
[9]   Rigid internal fixation of fractures of the proximal humerus in older patients [J].
Hintermann, B ;
Trouillier, HH ;
Schäfer, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1107-1112
[10]   PERCUTANEOUS STABILIZATION OF UNSTABLE FRACTURES OF THE HUMERUS [J].
JABERG, H ;
WARNER, JJP ;
JAKOB, RP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (04) :508-515