Fenestrated and Branched Endovascular Aortic Repair of Thoracoabdominal Aortic Aneurysm With More Than 4 Target Visceral Vessels due to Renovisceral Arterial Anatomical Variations: Feasibility and Early Results

被引:4
作者
Eleshra, Ahmed [1 ]
Panuccio, Giuseppe [1 ]
Spanos, Konstantinos [1 ]
Rohlffs, Fiona [1 ]
Tsilimparis, Nikolaos [1 ]
Koelbel, Tilo [1 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg, Dept Vasc Med, German Aort Ctr, Hamburg, Germany
关键词
aorta; anatomical variations; aortic aneurysm; endovascular repair; stent-graft; thoracoabdominal aortic aneurysm; visceral arteries; REPORTING STANDARDS; STENT-GRAFTS; DURABILITY; ENDOGRAFTS;
D O I
10.1177/15266028211016447
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: This study describes technical success, feasibility, and early results of fenestrated and branched endovascular aortic repair (F/B-EVAR) for treatment of thoracoabdominal aortic aneurysms (TAAAs) or pararenal aneurysms with more than 4 target visceral vessels (TVs) due to renovisceral arterial anatomical variations. Materials and Methods: Patients with TAAAs or pararenal aortic aneurysms who had more than 4 TVs due to renovisceral arterial anatomical variations of renal, celiac, and/or superior mesenteric arteries and received F/B-EVAR between January 2017 and September 2019 at a single aortic center were included in this study. We analyzed technical success, feasibility, and early outcomes. Results: Twelve patients (mean age 70 +/- 10 years, 9 males) were included. The anatomical variations included 6 right accessory renal arteries, 8 left accessory renal arteries, and 1 celiac artery variant. Stent-grafts were fenestrated, branched or combined in 6, 5, or 1 patients, respectively. The mean operating time was 346 +/- 120 minutes, the mean fluoroscopy time was 80 +/- 29 minutes, and the mean radiation dose area product was 430 +/- 219 Gy center dot cm(2). The mean contrast volume was 129 +/- 45 mL. The total number of TVs was 64; 5 TVs in 9 patients, 6 in 2 patients, and 7 in 1 patient. Technical success was achieved in all cases. The mean intensive care unit stay was 6 +/- 5 days, and the mean total hospital stay was 14 +/- 10 days. One patient died early (30-day). Early morbidities included respiratory complication in 1 patient, renal insufficiency in 1 patient, and wound infection in 2 patients. No spinal cord ischemia, stroke, or bowel ischemia occurred. Early computed tomography angiography showed 100% patency of the bridging covered stents and TVs. The mean follow-up was 13 +/- 4.3 months. No mortality or adverse major event occurred during the follow-up. Two patients with developed type Ic endoleak related to 1 right renal artery and 1 celiac artery covered stent. Patency of the TVs during follow-up was 100%. Conclusion: The use of F/B-EVAR for the treatment of TAAA with more than 4 TVs due to renovisceral arterial anatomical variations in our own experience is feasible and not related to increased morbidity and mortality.
引用
收藏
页码:692 / 699
页数:8
相关论文
共 26 条
[1]   Reporting standards for endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Blankensteijn, JD ;
Harris, PL ;
White, GH ;
Zarins, CK ;
Bernhard, VM ;
Matsumura, JS ;
May, J ;
Veith, FJ ;
Fillinger, MF ;
Rutherford, RB ;
Kent, KC .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1048-1060
[2]   SVS practice guidelines for the care of patients with an abdominal aortic aneurysm: Executive summary [J].
Chaikof, Elliot L. ;
Brewster, David C. ;
Dalman, Ronald L. ;
Makaroun, Michel S. ;
Illig, Karl A. ;
Sicard, Gregorio A. ;
Timaran, Carlos H. ;
Upchurch, Gilbert R., Jr. ;
Veith, Frank J. .
JOURNAL OF VASCULAR SURGERY, 2009, 50 (04) :880-896
[3]   Renal Function in Patients Treated With Abdominal Aortic Stentgraft Implantation With an Intentional Occlusion of Accessory Renal Artery [J].
Dzieciuchowicz, Lukasz ;
Espinosa, Gaudencio ;
Vigil Diaz, Carmen ;
Lavilla Roya, Francisco Javier ;
Arbizu Lostao, Javier .
ANNALS OF VASCULAR SURGERY, 2012, 26 (03) :299-305
[4]   Endovascular Repair Using a 7-Branch Stent-Graft for a Thoracoabdominal Aortic Aneurysm With Variant Renovisceral Artery Anatomy [J].
Eleshra, Ahmed ;
Spanos, Konstantinos ;
Panuccio, Giuseppe ;
Gronert, Catharina ;
Rohlffs, Fiona ;
Koelbel, Tilo .
JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (02) :231-236
[5]   Complex Endovascular Aortic Repair With a Branched Endograft to Revascularize 5 Renovisceral Vessels and an Intercostal Artery in a Marfan Patient [J].
Eleshra, Ahmed S. ;
Panuccio, Giuseppe ;
Rohlffs, Fiona ;
Scheerbaum, Martin ;
Tsilimparis, Nikolaos ;
Koelbel, Tilo .
JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (05) :736-741
[6]   Reporting standards for thoracic endovascular aortic repair (TEVAR) [J].
Fillinger, Mark F. ;
Greenberg, Roy K. ;
McKinsey, James F. ;
Chaikof, Elliot L. .
JOURNAL OF VASCULAR SURGERY, 2010, 52 (04) :1022-1033
[7]   Right brachial access is safe for branched endovascular aneurysm repair in complex aortic disease [J].
Fiorucci, Beatrice ;
Koelbel, Tilo ;
Rohlffs, Fiona ;
Heidemann, Franziska ;
Debus, Sebastian Eike ;
Tsilimparis, Nikolaos .
JOURNAL OF VASCULAR SURGERY, 2017, 66 (02) :360-366
[8]   Endovascular treatment of complex abdominal and thoracoabdominal type IV aortic aneurysms with fenestrated technology [J].
Georgiadis, George S. ;
van Herwaarden, Joost A. ;
Saengprakai, Wuttichai ;
Georgakarakos, Efstratios I. ;
Argyriou, Christos ;
Schoretsanitis, Nikolaos ;
Gianoukas, Athanasios D. ;
Lazarides, Miltos K. ;
Mol, Frans L. .
JOURNAL OF CARDIOVASCULAR SURGERY, 2017, 58 (04) :574-590
[9]   Long-term results after accessory renal artery coverage during endovascular aortic aneurysm repair [J].
Greenberg, Joshua I. ;
Dorsey, Chelsea ;
Dalman, Ronald L. ;
Lee, Jason T. ;
Harris, E. J. ;
Hernandez-Boussard, Tina ;
Mell, Matthew W. .
JOURNAL OF VASCULAR SURGERY, 2012, 56 (02) :291-297
[10]   Multibranched Stent-Grafts for the Treatment of Thoracoabdominal Aortic Aneurysms: A Systematic Review and Meta-analysis [J].
Hu, Zhongzhou ;
Li, Yue ;
Peng, Ran ;
Liu, Jie ;
Jia, Xin ;
Liu, Xiaoping ;
Xiong, Jiang ;
Ma, Xiaohui ;
Zhang, Hongpeng ;
Guo, Wei .
JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (04) :626-633