Use of the MagNA pure LC automated nucleic acid extraction system followed by real-time reverse transcription-PCR for ultrasensitive quantitation of hepatitis C virus RNA

被引:31
作者
Cook, L
Ng, KW
Bagabag, A
Corey, L
Jerome, KR
机构
[1] Fred Hutchinson Canc Res Ctr, Program Infect Dis, Seattle, WA 98109 USA
[2] Univ Washington, Ctr Med, Dept Lab Med, Seattle, WA 98195 USA
[3] Univ Washington, Ctr Med, Dept Med, Seattle, WA 98195 USA
关键词
D O I
10.1128/JCM.42.9.4130-4136.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Hepatitis C virus (HCV) infection is an increasing health problem worldwide. Quantitative assays for HCV viral load are valuable in predicting response to therapy and for following treatment efficacy. Unfortunately, most quantitative tests for HCV RNA are limited by poor sensitivity. We have developed a convenient, highly sensitive real-time reverse transcription-PCR assay for HCV RNA. The assay amplifies a portion of the 5' untranslated region of HCV, which is then quantitated using the TaqMan 7700 detection system. Extraction of viral RNA for our assay is fully automated with the MagNA Pure LC extraction system (Roche). Our assay has a 100% detection rate for samples containing 50 IU of HCV RNA/ml and is linear up to viral loads of at least 10(9) IU/ml. The assay detects genotypes la, 2a, and 3a with equal efficiency. Quantitative results by our assay correlate well with HCV viral load as determined by the Bayer VERSANT HCV RNA 3.0 bDNA assay. In clinical use, our assay is highly reproducible, with high and low control specimens showing a coefficient of variation for the logarithmic result of 2.8 and 7.0%, respectively. The combination of reproducibility, extreme sensitivity, and ease of performance makes this assay an attractive option for routine HCV viral load testing.
引用
收藏
页码:4130 / 4136
页数:7
相关论文
共 31 条
  • [1] The prevalence of hepatitis C virus infection in the United States, 1988 through 1994
    Alter, MJ
    Kruszon-Moran, D
    Nainan, OV
    McQuillan, GM
    Gao, FX
    Moyer, LA
    Kaslow, RA
    Margolis, HS
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (08) : 556 - 562
  • [2] [Anonymous], 2002, Gastroenterology, V123, P2082, DOI 10.1053/gast.2002.1232082
  • [3] Baker Danial E, 2003, Rev Gastroenterol Disord, V3, P93
  • [4] Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay
    Beld, M
    Sentjens, R
    Rebers, S
    Weegink, C
    Weel, J
    Sol, C
    Boom, R
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (03) : 788 - 793
  • [5] Comparison of real-time quantitative polymerase chain reaction with three other assays for quantitation of hepatitis C virus
    Enomoto, M
    Nishiguchi, S
    Shiomi, S
    Tanaka, M
    Fukuda, K
    Ueda, T
    Tamori, A
    Habu, D
    Takeda, T
    Yano, Y
    Otani, S
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2001, 16 (08) : 904 - 909
  • [6] Peginterferon alfa-2a plus ribavirin for chronic hepatitis C virus infection.
    Fried, MW
    Shiffman, ML
    Reddy, KR
    Smith, C
    Marinos, G
    Goncales, FL
    Haussinger, D
    Diago, M
    Carosi, G
    Dhumeaux, D
    Craxi, A
    Lin, A
    Hoffman, J
    Yu, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (13) : 975 - 982
  • [7] Evaluation of the MagNA pure LC instrument for extraction of hepatitis C virus RNA for the COBAS AMPLICOR hepatitis C Virus Test, version 2.0
    Germer, JJ
    Lins, MM
    Jensen, ME
    Harmsen, WS
    Ilstrup, DM
    Mitchell, PS
    Cockerill, FR
    Patel, R
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (08) : 3503 - 3508
  • [8] Kawai S, 1999, J MED VIROL, V58, P121, DOI 10.1002/(SICI)1096-9071(199906)58:2&lt
  • [9] 121::AID-JMV4&gt
  • [10] 3.0.CO