Performance characteristics of a pressure microsensor

被引:28
作者
Kaufman, KR
Wavering, T
Morrow, D
Davis, J
Lieber, RL
机构
[1] Mayo Clin & Mayo Fdn, Div Orthoped Res, Biomech Lab, Rochester, MN 55905 USA
[2] Luna Innovat, Blacksburg, VA 24060 USA
[3] Univ Calif San Diego, Dept Orthoped, San Diego, CA 92161 USA
[4] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92161 USA
关键词
pressure; fiber optic sensor; extrinsic Fabry-Perot interferometer;
D O I
10.1016/S0021-9290(02)00321-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new fiber optic microsensor has been developed for pressure measurement. The pressure microsensor is extremely small (360 mum). Performance characteristics of the microsensor were evaluated over a pressure range from 0 to 250 mm Hg. Five sensors were compared to a National Institute of Standards and Technology traceable reference pressure. The microsensor had an accuracy, repeatability, and linearity better than 2% full-scale output (FSO) and a hysteresis of 4.5% FSO. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 23 条
[1]   INTERSTITIAL-LYMPHATIC MECHANISMS IN THE CONTROL OF EXTRACELLULAR FLUID VOLUME [J].
AUKLAND, K ;
REED, RK .
PHYSIOLOGICAL REVIEWS, 1993, 73 (01) :1-78
[2]   The estimation of the subcutaneous tissue pressure by a direct method [J].
Burch, GE ;
Sodeman, WA .
JOURNAL OF CLINICAL INVESTIGATION, 1937, 16 (06) :845-850
[3]   A NEW TRANSDUCER-TIPPED FIBER OPTIC CATHETER FOR MEASURING INTRAMUSCULAR PRESSURES [J].
CRENSHAW, AG ;
STYF, JR ;
MUBARAK, SJ ;
HARGENS, AR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (03) :464-468
[4]   INTRAMUSCULAR PRESSURES DURING EXERCISE - AN EVALUATION OF A FIBER OPTIC TRANSDUCER-TIPPED CATHETER SYSTEM [J].
CRENSHAW, AG ;
STYF, JR ;
HARGENS, AR .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (02) :178-182
[5]   INTERSTITIAL FLUID PRESSURE IN MUSCLE AND COMPARTMENT SYNDROMES IN MAN [J].
HARGENS, AR ;
MUBARAK, SJ ;
OWEN, CA ;
GARETTO, LP ;
AKESON, WH .
MICROVASCULAR RESEARCH, 1977, 14 (01) :1-10
[6]   Accuracy of intravascular microcatheter pressure measurements:: an experimental study [J].
Henkes, H ;
Felber, SR ;
Wentz, KU ;
Czerwinski, F ;
Monstadt, H ;
Weber, W ;
Kühne, D .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (857) :448-451
[7]  
Kirkeby S, 2000, HISTOL HISTOPATHOL, V15, P61, DOI 10.14670/HH-15.61
[8]  
LANDERER AS, 1884, GEWEBESSPANNUNG EINF
[9]  
MATSEN FA, 1976, SURGERY, V79, P702
[10]   WICK CATHETER TECHNIQUE FOR MEASUREMENT OF INTRAMUSCULAR PRESSURE - NEW RESEARCH AND CLINICAL TOOL [J].
MUBARAK, SJ ;
HARGENS, AR ;
OWEN, CA ;
GARETTO, LP ;
AKESON, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (07) :1016-1020