Three-dimensional optical transfer function in differential confocal microscopy

被引:0
|
作者
Tan, J. [1 ]
Wang, H. [1 ]
Li, M. [1 ]
Liu, J. [1 ]
机构
[1] Harbin Inst Technol, Ultra Precis Optoelect Instrument Engn Ctr, 92 West Da Zhi St, Harbin 150001, Peoples R China
关键词
Differential confocal microscopy; optical transfer function; transfer capability;
D O I
10.1111/jmi.12326
中图分类号
TH742 [显微镜];
学科分类号
摘要
To reveal the fundamental characteristics of differential confocal microscopy (DCM), its imaging properties were analysed by studying the 3D optical transfer function (OTF). The zero transfer at zero frequency along the axial direction in DCM, which has not been well understood and is considerably different from the transfer behaviour in conventional confocal microscopy (CM), was elucidated. The integral expressions of the OTFs for CM and DCM and the subsequent simulation results showed that DCMs have higher transfer capability than CM in the axial direction at medium and high frequencies. Conventionally, the relative optimal defocusing amount in DCMs are determined through calculations of the gradient of the point spread functions in the spatial domain. In contrast, in this study, the OTF performances were compared and the optimal defocusing amount was found to be between 5 and 7. Lay Description Differential Confocal Microscopy (DCM) is designed employing two symmetrically defocused detectors of Confocal Microscopy (CM), which can improve the sensitivity of axial response of CM greatly. However, no one has ever inspected the three dimensional (3D) optical transfer function (OTF) for DCM to reveal its characteristics. This manuscript derives the formula of 3D OTF for DCM and analyzes the distribution of DCM for different defocusing amount to reveal the essence of DCM. We investigate the sectioning properties and transverse resolution of these optical systems by analyzing the 3D OTF along the axial and radial direction. The zero transfer capability of DCM in zero frequency along axial direction is also explained, which is confusing and greatly different from CM. This manuscript also gives the optimal range of defocusing amount through OTF analysis according to the information transfer capability.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 50 条
  • [21] Three-dimensional imaging: The future of reflectance confocal microscopy
    Reilly, Catherine
    Chuchvara, Nadiya
    Garfinkel, Jason
    Srivastava, Radhika
    Rubinstein, Gene
    Rao, Babaro
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2020, 83 (06) : AB222 - AB222
  • [22] Three-dimensional confocal microscopy of the living human eye
    Masters, BR
    Böhnke, M
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2002, 4 : 69 - 91
  • [23] Confocal Brillouin microscopy for three-dimensional mechanical imaging
    Scarcelli, Giuliano
    Yun, Seok Hyun
    NATURE PHOTONICS, 2008, 2 (01) : 39 - 43
  • [25] Three-dimensional coherent transfer function in reflection-mode confocal microscopy with two-zone phase filters
    Li, Lingxiao
    He, Yi
    Wang, Yuanyuan
    Li, Xiqi
    Wei, Ling
    Yang, Jinsheng
    Zhang, Yudong
    OPTIK, 2018, 170 : 70 - 81
  • [26] Three-dimensional transfer function of optical microscopes in reflection mode
    Lehmann, Peter
    Pahl, Tobias
    Journal of Microscopy, 2021, 284 (01): : 45 - 55
  • [27] Three-dimensional transfer function of optical microscopes in reflection mode
    Lehmann, Peter
    Pahl, Tobias
    JOURNAL OF MICROSCOPY, 2021, 284 (01) : 45 - 55
  • [28] Three-dimensional optical-transfer-function analysis of fiber-optical two-photon fluorescence microscopy
    Gu, M
    Bird, D
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (05): : 941 - 947
  • [29] DMD-based three-dimensional chromatic confocal microscopy
    Li, Shaobai
    Liang, Rongguang
    APPLIED OPTICS, 2020, 59 (14) : 4349 - 4356
  • [30] Three-dimensional morphology of LCPC using confocal fluorescence microscopy
    Tahara, S
    Niiyama, S
    Kumai, H
    Wakabayashi, T