MRI assessment of bone marrow oedema in the sacroiliac joints of patients with spondyloarthritis: is the SPAIR T2w technique comparable to STIR?

被引:21
作者
Dalto, Vitor Faeda [1 ]
Assad, Rodrigo Luppino [2 ]
Crema, Michel Daoud [3 ,4 ,5 ]
Louzada-Junior, Paulo [6 ]
Nogueira-Barbosa, Marcello Henrique [1 ]
机构
[1] Univ Sao Paulo, Ribeirao Preto Med Sch, Div Radiol, Dept Internal Med, Ave Bandeirantes 3900, BR-14048900 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Ribeirao Preto Med Sch, Div Clin Imunol, Dept Internal Med, Ave Bandeirantes 3900, BR-14048900 Ribeirao Preto, SP, Brazil
[3] Univ Paris VI, Serv Radiol, Hop St Antoine, Paris, France
[4] Boston Univ, Sch Med, Dept Radiol, Quantitat Imaging Ctr, Boston, MA 02215 USA
[5] Hosp Coracao HCor & Teleimagem, Dept Radiol, Sao Paulo, SP, Brazil
[6] Univ Sao Paulo, Ribeirao Preto Med Sch, Dept Internal Med, Ave Bandeirantes 3900, BR-14048900 Ribeirao Preto, SP, Brazil
关键词
Magnetic resonance imaging; Spondylarthritis; Spondylitis; ankylosing; Sacroiliitis; SOCIETY CLASSIFICATION CRITERIA; ANKYLOSING-SPONDYLITIS; FAT-SUPPRESSION; SEQUENCE;
D O I
10.1007/s00330-017-4746-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare short tau inversion-recovery (STIR) with another fat saturation method in the assessment of sacroiliac joint inflammation. This prospective cross-sectional study comprised 76 spondyloarthritis (SpA) patients who underwent magnetic resonance imaging of the sacroiliac joints in a 1.5-T scanner, using STIR, spectral attenuated inversion recovery (SPAIR) T2w and spectral presaturation with inversion recovery (SPIR) T1w post-contrast sequences. Two independent readers (R1 and R2) assessed the images using the Spondyloarthritis Research Consortium of Canada (SPARCC) score. We assessed agreement of the SPARCC scores for SPAIR T2w and STIR with that for T1 SPIR post-contrast (reference standard) using the St. Laurent coefficient. We evaluated each sequence using the concordance correlation coefficient (CCC). We observed a strong agreement between STIR and SPAIR T2w sequences. Lin's CCC was 0.94 for R1 and 0.84 for R2 for STIR and 0.94 for R1 and 0.84 for R2 for SPAIR. The interobserver evaluation revealed a good CCC of 0.79 for SPAIR and 0.78 for STIR. STIR technique and SPAIR T2w sequence showed high agreement in the evaluation of sacroiliac joint subchondral bone marrow oedema in patients with SpA. SPAIR T2w may be an alternative to the STIR sequence for this purpose. aEuro cent There are no studies evaluating which fat saturation technique should be used. aEuro cent SPAIR T2w may be an alternative to STIR for sacroiliac joint evaluation. aEuro cent The study will lead to changes in guidelines for spondyloarthritis.
引用
收藏
页码:3669 / 3676
页数:8
相关论文
共 22 条
[1]  
BYDDER G M, 1985, Magnetic Resonance Imaging, V3, P251, DOI 10.1016/0730-725X(85)90354-6
[2]   Role for imaging studies in ankylosing spondylitis [J].
Chary-Valckenaere, Isabelle ;
d'Agostino, Maria-Antonietta ;
Loeuille, Damien .
JOINT BONE SPINE, 2011, 78 (02) :138-143
[3]   Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System [J].
Del Grande, Filippo ;
Santini, Francesco ;
Herzka, Daniel A. ;
Aro, Michael R. ;
Dean, Cooper W. ;
Gold, Garry E. ;
Carrino, John A. .
RADIOGRAPHICS, 2014, 34 (01) :217-233
[4]   Fat suppression in MR imaging: Techniques and pitfalls [J].
Delfaut, EM ;
Beltran, J ;
Johnson, G ;
Rousseau, J ;
Marchandise, X ;
Cotten, A .
RADIOGRAPHICS, 1999, 19 (02) :373-382
[5]   Optimizing the MRI protocol of the sacroiliac joints in Spondyloarthritis: which para-axial sequence should be used? [J].
Giraudo, Chiara ;
Magnaldi, Silvia ;
Weber, Michael ;
Puchner, Antonia ;
Platzgummer, Hannes ;
Kainberger, Franz ;
Schueller-Weidekamm, Claudia .
EUROPEAN RADIOLOGY, 2016, 26 (01) :122-129
[6]   SACRO-ILIITIS IN 8 POPULATIONS [J].
GOFTON, JP ;
LAWRENCE, JS ;
BENNETT, PH ;
BURCH, TA .
ANNALS OF THE RHEUMATIC DISEASES, 1966, 25 (06) :528-+
[7]   MR signal in the sacroiliac joint space in spondyloarthritis: a new sign [J].
Laloo, Frederiek ;
Herregods, N. ;
Varkas, G. ;
Jaremko, J. L. ;
Baraliakos, X. ;
Elewaut, D. ;
Van den Bosch, F. ;
Verstraete, K. ;
Jans, L. .
EUROPEAN RADIOLOGY, 2017, 27 (05) :2024-2030
[8]   A CONCORDANCE CORRELATION-COEFFICIENT TO EVALUATE REPRODUCIBILITY [J].
LIN, LI .
BIOMETRICS, 1989, 45 (01) :255-268
[9]   Development of an ASAS-endorsed disease activity score (ASDAS) in patients with ankylosing spondylitis [J].
Lukas, C. ;
Landewe, R. ;
Sieper, J. ;
Dougados, M. ;
Davis, J. ;
Braun, J. ;
van der Linden, S. ;
van der Heijde, D. .
ANNALS OF THE RHEUMATIC DISEASES, 2009, 68 (01) :18-24
[10]   Development and Validation of Web-based Training Modules for Systematic Evaluation of Active Inflammatory Lesions in the Spine and Sacroiliac Joints in Spondyloarthritis [J].
Maksymowych, Walter P. ;
Dhillon, Suhkvinder S. ;
Chiowchanwisawakit, Praveena ;
Pedersen, Susanne J. ;
Martinez, Bernardo ;
Ostergaard, Mikkel ;
Lambert, Robert G. W. .
JOURNAL OF RHEUMATOLOGY, 2009, 36 :48-57