Symmetric diffeomorphic modeling of longtudinal structural MRI

被引:240
作者
Ashburner, John [1 ]
Ridgway, Gerard R. [1 ]
机构
[1] UCL, Inst Neurol, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
基金
英国医学研究理事会; 英国惠康基金;
关键词
diffeommphisms; geodesic shooting; shape modeling; non-linear registration; longitudinal registration; inverse consistency; symmetry; transitivity; IMAGE REGISTRATION; NONRIGID REGISTRATION; ACCURATE; VOLUME;
D O I
10.3389/fnins.2012.00197
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This technology report describes the longitudinal registration approach that we intend to incorporate into SPM12. It essentially describes a group-wise intra-subject modeling framework, which combines diffeomorphic and rigid-body registration, incorporating a correction for the intensity inhomogeneity artifact usually seen in MRI data. Emphasis is placed on achieving internal consistency and accounting for many of the mathematical subtleties that most implementations overlook. The implementation was evaluated using examples from the OASIS Longitudinal MRI Data in Non-demented and Demented Older Adults.
引用
收藏
页数:19
相关论文
共 53 条
  • [1] COMPUTING THE FRECHET DERIVATIVE OF THE MATRIX EXPONENTIAL, WITH AN APPLICATION TO CONDITION NUMBER ESTIMATION
    Al-Mohy, Awad H.
    Higham, Nicholas J.
    [J]. SIAM JOURNAL ON MATRIX ANALYSIS AND APPLICATIONS, 2008, 30 (04) : 1639 - 1657
  • [2] Arsigny V., 2006, Ph. D. Dissertation
  • [3] High-dimensional image registration using symmetric priors
    Ashburner, J
    Andersson, JLR
    Friston, KJ
    [J]. NEUROIMAGE, 1999, 9 (06) : 619 - 628
  • [4] Unified segmentation
    Ashburner, J
    Friston, KJ
    [J]. NEUROIMAGE, 2005, 26 (03) : 839 - 851
  • [5] A fast diffeomorphic image registration algorithm
    Ashburner, John
    [J]. NEUROIMAGE, 2007, 38 (01) : 95 - 113
  • [6] Diffeomorphic registration using geodesic shooting and Gauss-Newton optimisation
    Ashburner, John
    Friston, Karl J.
    [J]. NEUROIMAGE, 2011, 55 (03) : 954 - 967
  • [7] Computing average shaped tissue probability templates
    Ashburner, John
    Friston, Karl J.
    [J]. NEUROIMAGE, 2009, 45 (02) : 333 - 341
  • [8] Symmetric diffeomorphic image registration with cross-correlation: Evaluating automated labeling of elderly and neurodegenerative brain
    Avants, B. B.
    Epstein, C. L.
    Grossman, M.
    Gee, J. C.
    [J]. MEDICAL IMAGE ANALYSIS, 2008, 12 (01) : 26 - 41
  • [9] Symmetric data attachment terms for large deformation image registration
    Beg, Mirza Faisal
    Khan, Ali
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (09) : 1179 - 1189
  • [10] BroNielsen M, 1996, LECT NOTES COMPUT SC, V1131, P267