Evaluation of the toric implantable collamer lens for simultaneous treatment of myopia and astigmatism

被引:21
作者
Price, Marianne O. [1 ]
Price, Francis W., Jr. [2 ]
机构
[1] Cornea Res Fdn Amer, Indianapolis, IN 46260 USA
[2] Price Vis Grp, Indianapolis, IN USA
关键词
astigmatism; keratoconus; myopia; pellucid marginal degeneration; phakic intraocular lens; PHAKIC INTRAOCULAR-LENS; COLLAGEN CROSS-LINKING; IN-SITU KERATOMILEUSIS; LASER PERIPHERAL IRIDOTOMY; ICL IMPLANTATION; PATIENT SATISFACTION; ROTATIONAL STABILITY; REFRACTIVE ERRORS; CLINICAL-OUTCOMES; AXIS ALIGNMENT;
D O I
10.1586/17434440.2015.984685
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Myopic astigmatism is a prevalent condition that can be treated with spectacles, contact lenses, or laser refractive surgery. However, these treatment options have functional limitations at higher levels of refractive error. The toric implantable collamer lens is designed to treat a broad range of refractive error, generally up to -18 diopters with +1 to +6 diopters of astigmatism. Approval for a more limited treatment range of up to 15 diopters of myopia with +1 to +4 diopters of astigmatism is being sought in the US, where this device has not yet received marketing approval. Surgical correction of high-myopic astigmatism can be life-altering and allow people to participate in activities that were not previously feasible because of visual limitations. The toric implantable collamer lens is implanted behind the iris and in front of the natural crystalline lens. With earlier lens designs, it was necessary to create an iridectomy or iridotomy to prevent pupillary block. The newest toric implantable collamer lens model has a small central hole that is not visually noticeable. This eliminates the need to create a hole in the iris, thereby enhancing the safety of the procedure.
引用
收藏
页码:25 / 39
页数:15
相关论文
共 70 条
  • [1] Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism
    Alfonso, J. F.
    Lisa, C.
    Fernandez-Vega Cueto, L.
    Fernandes, P.
    Gonzalez-Meijome, J. M.
    Montes Mico, R.
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (03) : 967 - 975
  • [2] Collagen copolymer toric phakic intraocular lens for myopic astigmatism: One-year follow-up
    Alfonso, Jose F.
    Lisa, Carlos
    Alfonso-Bartolozzi, Belen
    Perez-Vives, Cari
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (07) : 1155 - 1162
  • [3] Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up
    Alfonso, Jose F.
    Baamonde, Begona
    Fernandez-Vega, Luis
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 873 - 880
  • [4] Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism
    Alfonso, Jose F.
    Baamonde, Begona
    Madrid-Costa, David
    Fernandes, Paulo
    Jorge, Jorge
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) : 1349 - 1357
  • [5] Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Lisa, Carlos
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06) : 906 - 916
  • [6] Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism One-year follow-up
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) : 568 - 576
  • [7] Posterior chamber phakic intraocular lenses after penetrating keratoplasty
    Alfonso, Jose F.
    Lisa, Carlos
    Abdelhamid, Abdelhamid
    Montes-Mico, Robert
    Poo-Lopez, Arancha
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) : 1166 - 1173
  • [8] [Anonymous], SURG VIS TOR IMPL CO
  • [9] Bamashmus MA, 2013, SAUDI MED J, V34, P913
  • [10] Toric implantable collamer lens for patients with moderate to severe myopic astigmatism: 12-month follow-up
    Bhikoo, Riyaz
    Rayner, Sandra
    Gray, Trevor
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (05) : 467 - 474