Solid-Phase Covalent Immobilization of Upconverting Nanoparticles for Biosensing by Luminescence Resonance Energy Transfer

被引:27
作者
Doughan, Samer [1 ]
Han, Yi [1 ]
Uddayasankar, Uvaraj [1 ]
Krull, Ulrich J. [1 ]
机构
[1] Univ Toronto, Chem Sensors Grp, Dept Chem & Phys Sci, Mississauga, ON L5L 1C6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
upconverting nanoparticles; quantum dots; luminescence resonance energy transfer; solid-phase assay; biosensor; UP-CONVERSION NANOPARTICLES; ACID HYBRIDIZATION ASSAY; QUANTUM DOTS; CONVERTING PHOSPHORS; THROMBIN DETECTION; LATERAL-FLOW; PAPER; DONORS; DETECT; SENSOR;
D O I
10.1021/am503391m
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Monodisperse water-soluble upconverting nanoparticles (UCNPs) were immobilized onto modified glass substrates for development of biosensing surfaces that operated using luminescence resonance energy transfer (LRET). Amine modified UCNPs were prepared from oleic acid capped UCNPs by ligand exchange using o-phosphorylethanolamine (PEA). PEA-UCNPs were covalently immobilized on aldehyde functionalized coverslips. Environmental scanning electron microscopy (ESEM) images indicated a homogeneous distribution of UCNPs on surfaces with a high immobilization density of approximately 1.3 x 10(11) UCNP cm(-2). This is the first account of covalent immobilization of UCNPs for bioassay and biosensor development where the density is on par with the high immobilization densities reported for other types of nanoparticles. The functionality and stability of the immobilized NPs were demonstrated by examining an LRET-based bioassay. The well-known sandwich assay for the detection of thrombin was selected as a model in which UCNPs were used as donors and quantum dots (QDs) as acceptors. The closely packed UCNPs on the glass surface showed a 2.5-fold enhancement in assay sensitivity compared to less-densely packed surfaces. In addition, a 1.5-fold enhancement in energy transfer efficiency was shown for solid-phase compared to solution-phase LRET.
引用
收藏
页码:14061 / 14068
页数:8
相关论文
共 55 条
[1]   Multidentate surface ligand exchange for the immobilization of CdSe/ZnS quantum dots and surface quantum dot-oligonucleotide conjugates [J].
Algar, W. Russ ;
Krull, Ulrich J. .
LANGMUIR, 2008, 24 (10) :5514-5520
[2]   Upconversion and anti-stokes processes with f and d ions in solids [J].
Auzel, F .
CHEMICAL REVIEWS, 2004, 104 (01) :139-173
[3]   Up-conversion FRET from Er3+/Yb3+:NaYF4 Nanophosphor to CdSe Quantum Dots [J].
Bednarkiewicz, Artur ;
Nyk, Marcin ;
Samoc, Marek ;
Strek, Wieslaw .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (41) :17535-17541
[4]   SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN [J].
BOCK, LC ;
GRIFFIN, LC ;
LATHAM, JA ;
VERMAAS, EH ;
TOOLE, JJ .
NATURE, 1992, 355 (6360) :564-566
[5]   Surface Modification of Upconverting NaYF4 Nanoparticles with PEG-Phosphate Ligands for NIR (800 nm) Biolabeling within the Biological Window [J].
Boyer, John-Christopher ;
Manseau, Marie-Pascale ;
Murray, Jill I. ;
van Veggel, Frank C. J. M. .
LANGMUIR, 2010, 26 (02) :1157-1164
[6]   Remote-Control Photorelease of Caged Compounds Using Near-Infrared Light and Upconverting Nanoparticles [J].
Carling, Carl-Johan ;
Nourmohammadian, Farahnaz ;
Boyer, John-Christopher ;
Branda, Neil R. .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (22) :3782-3785
[7]   Aptamer-based sensing for thrombin in red region via fluorescence resonant energy transfer between NaYF4:Yb,Er upconversion nanoparticles and gold nanorods [J].
Chen, Hongqi ;
Yuan, Fei ;
Wang, Shaozhen ;
Xu, Juan ;
Zhang, YiYan ;
Wang, Lun .
BIOSENSORS & BIOELECTRONICS, 2013, 48 :19-25
[8]   Highly-Sensitive Multiplexed in vivo Imaging Using PEGylated Upconversion Nanoparticles [J].
Cheng, Liang ;
Yang, Kai ;
Zhang, Shuai ;
Shao, Mingwang ;
Lee, Shuittong ;
Liu, Zhuang .
NANO RESEARCH, 2010, 3 (10) :722-732
[9]   A user-friendly, highly sensitive assay to detect the IFN-γ secretion by T cells [J].
Corstjens, Paul L. A. M. ;
Zuiderwijk, Michel ;
Tanke, Hans J. ;
van der Ploeg-van Schip, Jolien J. ;
Ottenhoff, Tom H. M. ;
Geluk, Annemiek .
CLINICAL BIOCHEMISTRY, 2008, 41 (06) :440-444
[10]   Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum [J].
Corstjens, Paul L. A. M. ;
van Lieshout, Lisette ;
Zuiderwijk, Michel ;
Kornelis, Dieuwke ;
Tanke, Hans J. ;
Deelder, Andre M. ;
van Dam, Govert J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) :171-176