Transducer Loading Effect on the Performance of PZT-Based SHM Systems

被引:24
作者
Baptista, Fabricio Guimaraes [1 ]
Vieira, Jozue [1 ]
机构
[1] Sao Paulo State Univ, UNESP, Dept Elect Engn, Sao Paulo, Brazil
关键词
IMPEDANCE; ADMITTANCE; DEVICES;
D O I
10.1109/TUFFC.2010.1497
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the last years, the piezoelectric transducers of lead zirconate titanate (PZT) have been widely used in structural health monitoring (SHM) systems based on the electromechanical (E/M) impedance technique. Although many studies indicate the successful use of PZT in damage detection, some practical considerations still have to be considered in real applications. In this work, the effect of the transducer loading caused by mechanical impedance of the host structure is analyzed using an equivalent electromechanical circuit. Tests were performed on structures with various sizes and the results show that the transducer loading significantly reduces the sensitivity of the system for detecting structural damages.
引用
收藏
页码:933 / 941
页数:9
相关论文
共 19 条
[1]   Influence of loading on the electromechanical admittance of piezoceramic transducers [J].
Annamdas, Venu Gopal Madhav ;
Yang, Yaowen ;
Soh, Chee Kiong .
SMART MATERIALS AND STRUCTURES, 2007, 16 (05) :1888-1897
[2]  
[Anonymous], 1987, 176 IEEE
[3]  
[Anonymous], THESIS VIRGINIA POLY
[4]   Modeling piezoelectric and piezomagnetic devices and structures via equivalent networks [J].
Ballato, A .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (05) :1189-1240
[5]   A New Impedance Measurement System for PZT-Based Structural Health Monitoring [J].
Baptista, Fabricio Guimaraes ;
Vieira Filho, Jozue .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (10) :3602-3608
[6]  
Giurgiutiu V, 1997, P INT WORKSH STRUCT, P433
[7]   MULTILAYER IMPEDANCE MATCHING SCHEMES FOR BROADBANDING OF WATER LOADED PIEZOELECTRIC TRANSDUCERS AND HIGH Q ELECTRIC RESONATORS [J].
GOLL, JH ;
AULD, BA .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1975, SU22 (01) :52-54
[8]  
GYEKENYESI AL, 2005, TM2005213579 NASA
[9]   FEM/BEM impedance and power analysis for measured LGS SH-SAW devices [J].
Kenny, TD ;
Pollard, TB ;
Berkenpas, E ;
da Cunha, MP .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (02) :402-411
[10]   EFFECTS OF BACKING AND MATCHING ON PERFORMANCE OF PIEZOELECTRIC CERAMIC TRANSDUCERS [J].
KOSSOFF, G .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1966, SU13 (01) :20-&