Improved Signal-Injection Sensorless Control Robust to Inverter Nonlinearity Effects by Prediction of Voltage Disturbance

被引:5
|
作者
Lee, Yoon-Ro [1 ]
Kwon, Yong-Cheol [1 ]
Sul, Seung-Ki [1 ]
机构
[1] Seoul Natl Univ, Dept Elect & Comp Engn, Seoul, South Korea
来源
2019 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) | 2019年
关键词
Signal injection senseless drive; inverter nonlinearity; switching-instant current; voltage error calculation; iteration method; estimated position error compensation; INDUCTION;
D O I
10.1109/itec.2019.8790628
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In signal-injection sensorless control, the estimated rotor position includes considerable error induced by the inverter nonlinearity effects. It would degrade overall performances of the sensorless drive, and it could even result in the failure of the position tracking. In this paper, an improved signal-injection sensorless control thanks to the compensation of the voltage error is proposed. The compensation depends on a precise calculation method of the voltage error induced by the inverter nonlinearity. The proposed method effectively reduces the voltage disturbance especially under the switching frequency injection for sensorless control. The performance of the proposed method is verified by computer simulations and experimental results.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] HF Pulsating Carrier Voltage Injection Method Based on Improved Position Error Signal Extraction Strategy for PMSM Position Sensorless Control
    Mai, Zhiqin
    Xiao, Fei
    Fu, Kangzhuang
    Liu, Jilong
    Lian, Chuanqiang
    Li, Kefeng
    Zhang, Weiwei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (08) : 9348 - 9360
  • [42] Sensorless position control of linear tubular motors with pulsating voltage injection and improved position observer
    Cupertino, F.
    Giangrande, P.
    Salvatore, L.
    Pellegrino, G.
    2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, : 619 - +
  • [43] Model Predictive Control for a Voltage Sensorless Grid-Connected Inverter With LCL Filter Using Lumped Disturbance Observer
    Nam, Nguyen Ngoc
    Nguyen, Ngoc-Duc
    Lee, Young Il
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2023, 11 (03) : 3050 - 3063
  • [44] Voltage Control of Microgrid Inverter Based on Improved Second-order Linear Active Disturbance Rejection Control
    Yang L.
    Zeng J.
    Ma W.
    Huang Z.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (04): : 146 - 153
  • [45] ILC-Based Voltage Compensation Method for PMSM Sensorless Control Considering Inverter Nonlinearity and Sampling Current DC Bias
    Wang, Yangrui
    Xu, Yongxiang
    Zou, Jibin
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2020, 67 (07) : 5980 - 5989
  • [46] Research on the Sensorless Control of PMSM based on the Improved Phase-locked Loop and Fluctuating High-frequency Voltage Signal Injection Method
    Xu Xiangshuai
    Feng Yaojing
    Huang Shoudao
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [48] Sensorless Control of Permanent Magnet Synchronous Machine with Magnetic Saliency Tracking Based on Voltage Signal Injection
    Ilioudis, Vasilios C.
    MACHINES, 2020, 8 (01)
  • [49] Optimized Active Disturbance Rejection Control With Resonant Extended State Observer for Grid Voltage Sensorless LCL-Filtered Inverter
    Tran, Thuy Vi
    Kim, Kyeong-Hwa
    Lai, Jih-Sheng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (11) : 13317 - 13331
  • [50] Improved Control Strategy of Grid Connected Inverter without Phase Locked Loop on PCC Voltage Disturbance
    Chen, Liang
    Heng Nian
    Lou, Boliang
    Huang, HongYang
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 4244 - 4251