Plastic scintillation dosimetry and its application to radiotherapy

被引:153
作者
Beddar, A. S. [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Div Radiat Oncol, Houston, TX 77030 USA
关键词
dosimetry; scintillators; scintillation detectors; fiberoptic detectors; radiotherapy detectors;
D O I
10.1016/j.radmeas.2007.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We present a review of the dosimetric characteristics and properties of plastic scintillation detectors when exposed to high-energy photon and electron beams. The detectors show many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity, resistance to radiation damage, and near temperature independence. Therefore, these detectors do not require the usual conversion and/or correction factors used for other commonly used detectors to convert the dosimeter reading to absorbed dose. Furthermore, due to their small detecting volume, plastic scintillation detectors exhibit excellent spatial resolution. One issue concerning detector performance is the radiation-induced light arising in the optical fibers that carry the scintillator output to a photomultiplier tube or photodiode. The radiation induced light produced in optical fibers could be a combination of Cerenkov emission, fluorescence or luminescence depending on the type of material of the fibers utilized. For pure fused silica optical fibers, this spurious light emission is predominantly due to Cerenkov. This is most easily resolved by subtracting the signals from two sets of optical fibers, one carrying the entire signal and the other carrying just the Cerenkov background. Finally, we present two applications for plastic scintillation detectors in clinical radiotherapy: stereotactic radiosurgery dosimetry and the quality assurance of Co-60 and high-energy therapy beams. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S124 / S133
页数:10
相关论文
共 24 条
[1]  
[Anonymous], 1983, MED PHYS, V10, P741
[2]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[3]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[4]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[5]   Plastic scintillation dosimetry for radiation therapy: minimizing capture of Cerenkov radiation noise [J].
Beddar, AS ;
Suchowerska, N ;
Law, SH .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (05) :783-790
[6]   A NEW SCINTILLATOR DETECTOR SYSTEM FOR THE QUALITY ASSURANCE OF CO-60 AND HIGH-ENERGY THERAPY MACHINES [J].
BEDDAR, AS .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (02) :253-263
[7]   Plastic scintillation dosimetry: optimization of light collection efficiency [J].
Beddar, AS ;
Law, S ;
Suchowerska, N ;
Mackie, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (09) :1141-1152
[8]   A miniature "scintillator-fiberoptic-PMT" detector system for the dosimetry of small fields in stereotactic radiosurgery [J].
Beddar, AS ;
Kinsella, TJ ;
Ikhlef, A ;
Sibata, CH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :924-928
[9]   CERENKOV LIGHT GENERATED IN OPTICAL FIBERS AND OTHER LIGHT PIPES IRRADIATED BY ELECTRON-BEAMS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (04) :925-935
[10]   A GENERAL THEORY OF CAVITY IONISATION [J].
BURLIN, TE .
BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (466) :727-&