Tissue harmonic synthetic aperture ultrasound imaging

被引:17
作者
Hemmsen, Martin Christian [1 ]
Rasmussen, Joachim Hee [1 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Ctr Fast Ultrasound Imaging, Dept Elect Engn, DK-2800 Lyngby, Denmark
关键词
FINITE-AMPLITUDE DISTORTION; RESOLUTION; SYSTEM;
D O I
10.1121/1.4893902
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Synthetic aperture sequential beamforming (SASB) and tissue harmonic imaging (THI) are combined to improve the image quality of medical ultrasound imaging. The technique is evaluated in a comparative study against dynamic receive focusing (DRF). The objective is to investigate if SASB combined with THI improves the image quality compared to DRF-THI. The major benefit of SASB is a reduced bandwidth between the probe and processing unit. A BK Medical 2202 Ultraview ultrasound scanner was used to acquire beamformed RF data for offline evaluation. The acquisition was made interleaved between methods, and data were recorded with and without pulse inversion for tissue harmonic imaging. Data were acquired using a Sound Technology 192 element convex array transducer from both a wire phantom and a tissue mimicking phantom to investigate spatial resolution and penetration. In vivo scans were also performed for a visual comparison. The spatial resolution for SASB-THI is on average 19% better than DRI-THI, and the investigation of penetration showed equally good signal-to-noise ratio. In vivo B-mode scans were made and compared. The comparison showed that SASB-THI reduces the artifact and noise interference and improves image contrast and spatial resolution. (C) 2014 Acoustical Society of America.
引用
收藏
页码:2050 / 2056
页数:7
相关论文
共 42 条
[1]  
American Institute of Ultrasound in Medicine National Electrical Manufacturers Association, 2004, NEMA STAND PUBL
[2]  
[Anonymous], 2008, GUID IND FDA STAFF I
[3]  
Averkiou MA, 2000, ULTRASON, P1563, DOI 10.1109/ULTSYM.2000.921622
[4]   Measurements of harmonic generation in a focused finite-amplitude sound beam [J].
Averkiou, MA ;
Hamilton, MF .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 98 (06) :3439-3442
[5]   A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems [J].
Bae, MH ;
Jeong, MK .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (06) :1510-1519
[6]  
BAE MH, 2008, P IEEE ULTRASON S, P1258
[7]  
Beyer R. T., 1974, Technical Report
[8]   Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging [J].
Christopher, T .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (01) :125-139
[9]  
Curlander J. C., 1991, Synthetic Aperture Radar
[10]   Second harmonic imaging using synthetic aperture sequential beamforming [J].
Du, Yigang ;
Rasmussen, Joachim ;
Jensen, Henrik ;
Jensen, Jorgen Arendt .
2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, :2261-2264