Easy to use and rapid isolation and detection of a viral nucleic acid by using paramagnetic microparticles and carbon nanotubes-based screen-printed electrodes

被引:42
作者
Adam, Vojtech [1 ,2 ]
Huska, Dalibor [1 ,3 ]
Hubalek, Jaromir [4 ]
Kizek, Rene [1 ]
机构
[1] Mendel Univ Brno, Dept Chem & Biochem, CZ-61300 Brno, Czech Republic
[2] Mendel Univ Brno, Dept Anim Nutr & Forage Prod, CZ-61300 Brno, Czech Republic
[3] Mendel Univ Brno, Dept Plant Biol, Fac Agron, CZ-61300 Brno, Czech Republic
[4] Brno Univ Technol, Dept Microelect, Fac Elect Engn & Commun, CZ-60200 Brno, Czech Republic
关键词
Paramagnetic microparticles; Viral nucleic acid; Electrochemical detection; Voltammetry; Screen-printed electrode; ON-A-CHIP; DNA HYBRIDIZATION; ELECTROCHEMICAL DETECTION; AVIDIN; INFLUENZA; PROTEIN; BIOTIN;
D O I
10.1007/s10404-009-0464-z
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A method that is easy to use, rapid, with a low cost of detecting viral nucleic acid in a biological sample represents the essential tool in targeted therapy. In this study, we report the use of paramagnetic microparticles covered by streptavidin and modified by an oligonucleotide probe with a specific viral sequence labeled by biotin to detect human immunodeficiency virus (HIV) and influenza virus subtype H5N1. The viral nucleic acids were primarily detected by adsorptive transfer stripping technique coupled with square wave voltammetry using carbon paste, hanging mercury drop or carbon nanotubes-based screen-printed working electrodes. Detection limits were estimated for both sequences down to picograms per 3 mu l. To isolate the viral sequences, paramagnetic microparticles covered with biotin-labeled oligonucleotides were used. We calculated the yield of isolation for H5N1 and/or HIV sequences, which was defined as "isolated concentration of viral nucleic acid sequence"/"given viral nucleic acid sequence" x 100. We estimated the yield for both sequences as 59%. Moreover, we studied the influence of human serum, dsDNA and non-complementary sequence of nucleic acids on isolation of viral nucleic acids. We also used carbon nanotubes-based screen-printed electrodes coupled with micro-flow instrument to detect viral nucleic acids. We were able to isolate and detect nanogram amounts of nucleic acids.
引用
收藏
页码:329 / 339
页数:11
相关论文
共 44 条
  • [1] An electrochemical detection of metallothioneins at the zeptomole level in nanolitre volumes
    Adam, Vojtech
    Baloun, Jiri
    Fabrik, Ivo
    Trnkova, Libuse
    Kizek, Rene
    [J]. SENSORS, 2008, 8 (04): : 2293 - 2305
  • [2] Electrochemical DNA sensors
    Drummond, TG
    Hill, MG
    Barton, JK
    [J]. NATURE BIOTECHNOLOGY, 2003, 21 (10) : 1192 - 1199
  • [3] On chip cell separator using magnetic bead-based enrichment and depletion of various surface markers
    Estes, Matthew D.
    Do, Jaephil
    Ahn, Chong H.
    [J]. BIOMEDICAL MICRODEVICES, 2009, 11 (02) : 509 - 515
  • [4] Electrochemical stripping techniques in analysis of nucleic acids and their constituents
    Fojta, Miroslav
    Jelen, Frantisek
    Havran, Ludek
    Palecek, Emil
    [J]. CURRENT ANALYTICAL CHEMISTRY, 2008, 4 (03) : 250 - 262
  • [5] Emergence of simian foamy viruses in humans: facts and unanswered questions
    Gessain, Antoine
    Calattini, Sara
    [J]. FUTURE VIROLOGY, 2008, 3 (01) : 71 - 81
  • [6] Electrical detection of TATA binding protein at DNA-modified microelectrodes
    Gorodetsky, Alon A.
    Ebrahim, Ali
    Barton, Jacqueline K.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (10) : 2924 - 2925
  • [7] HUSKA D, 2009, TALANTA IN PRESS, DOI DOI 10.1016/J.TALANTA.2009.1004.1007
  • [8] Dependence of adenine isolation efficiency on the chain length evidenced using paramagnetic particles and voltammetry measurements
    Huska, Dalibor
    Adam, Vojtech
    Trnkova, Libuse
    Kizek, Rene
    [J]. JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2009, 321 (10) : 1474 - 1477
  • [9] Miniaturized electrochemical detector as a tool for detection of DNA amplified by PCR
    Huska, Dalibor
    Hubalek, Jaromir
    Adam, Vojtech
    Kizek, Rene
    [J]. ELECTROPHORESIS, 2008, 29 (24) : 4964 - 4971
  • [10] Microanalysis of DNA by stripping transfer voltammetry
    Jelen, F
    Kourilová, A
    Pecinka, P
    Palecek, E
    [J]. BIOELECTROCHEMISTRY, 2004, 63 (1-2) : 249 - 252