High-performance chromatofocusing using linear and concave pH gradients formed with simple buffer mixtures II. Separation of proteins

被引:24
作者
Kang, XZ [1 ]
Bates, RC [1 ]
Frey, DD [1 ]
机构
[1] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Baltimore, MD 21250 USA
基金
美国国家科学基金会;
关键词
chromatofocusing; pH gradients; buffer composition; gradient elution; proteins; hemoglobins; myoglobin;
D O I
10.1016/S0021-9673(00)00573-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation of proteins using high-performance chromatofocusing with linear or concave pH gradients formed using simple mixtures of buffering species in the elution buffer is investigated experimentally. The separation achieved is comparable to that using polyampholyte elution buffers with these types of systems. More specifically, protein band widths at one half of the band height in the range between 0.1 and 0.025 pH units were observed, and good resolution was achieved of protein variants differing by a single amino acid residue in separation times of 30 min or less. An especially useful elution buffer is investigated that contains only four buffering species and that produces a linear pH gradient in the range between pH 9.5 and 6.0 when used together with a particular high-performance column packing made specifically for chromatofocusing. This elution buffer and column packing combination is evaluated by using it for the chromatofocusing of equine myoglobin and human hemoglobin variants. Additional applications are described in which a polyethyleneimine derivatized silica column packing and a pH gradient that is concave in shape are used for the separation of proteins in an E. coli cell lysate. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:37 / 43
页数:7
相关论文
共 13 条
[1]  
ABRAHAM EC, 1985, CLIN BIOCH ANAL GLYC, V19
[2]   CHROMATOFOCUSING OF HUMAN HEMOGLOBINS [J].
ALEXANDER, NM ;
NEELEY, WE .
JOURNAL OF CHROMATOGRAPHY, 1982, 230 (01) :137-141
[3]  
*AM PHARM BIOT, 1981, CHROM POL PBE
[4]  
*AM PHARM BIOT, 1999, BIOD 99 PROD CAT, P532
[5]   Quasi-linear pH gradients for chromatofocusing using simple buffer mixtures: local equilibrium theory and experimental verification [J].
Bates, RC ;
Frey, DD .
JOURNAL OF CHROMATOGRAPHY A, 1998, 814 (1-2) :43-54
[6]   FAST CHROMATOFOCUSING OF HUMAN-SERUM PROTEINS WITH SPECIAL REFERENCE TO ALPHA-1-ANTITRYPSIN AND GC-GLOBULIN [J].
FAGERSTAM, LG ;
LIZANA, J ;
AXIOFREDRIKSSON, UB ;
WAHLSTROM, L .
JOURNAL OF CHROMATOGRAPHY, 1983, 266 (AUG) :523-532
[7]   Intraparticle mass transfer in high-speed chromatography of proteins [J].
Farnan, D ;
Frey, DD ;
Horvath, C .
BIOTECHNOLOGY PROGRESS, 1997, 13 (04) :429-439
[8]   STUDIES ON HETEROGENEITY OF HEMOGLOBIN .9. USE OF TRIS(HYDROXYMETHYL)AMINOMETHANE-HC1 BUFFERS IN ANION-EXCHANGE CHROMATOGRAPHY OF HEMOGLOBINS [J].
HUISMAN, THJ ;
DOZY, AM .
JOURNAL OF CHROMATOGRAPHY, 1965, 19 (01) :160-&
[9]   CHROMATOFOCUSING - ISOELECTRIC-FOCUSING ON ION-EXCHANGE COLUMNS .2. EXPERIMENTAL-VERIFICATION [J].
SLUYTERMAN, LAA ;
WIJDENES, J .
JOURNAL OF CHROMATOGRAPHY, 1978, 150 (01) :31-44
[10]   CHROMATOFOCUSING .4. PROPERTIES OF AN AGAROSE POLYETHYLENEIMINE ION-EXCHANGER AND ITS SUITABILITY FOR PROTEIN SEPARATIONS [J].
SLUYTERMAN, LAA ;
WIJDENES, J .
JOURNAL OF CHROMATOGRAPHY, 1981, 206 (03) :441-447