Permanent and biodegradable polymer coatings in the absence of antiproliferative drugs in a porcine model of coronary artery stenting

被引:11
|
作者
Koppara, Tobias [1 ]
Wittchow, Eric [2 ]
Byrne, Robert A. [1 ]
Bayer, Gerd [2 ]
Diener, Tobias [2 ]
Joner, Michael [3 ]
机构
[1] Deutsch Herzzentrum Munich, Munich, Germany
[2] Biotronik SE & Co KG, Erlangen, Germany
[3] CVPath Inst Inc, Gaithersburg, MD USA
关键词
coronary artery disease; drug delivery; drug-eluting stents; REDUCES NEOINTIMAL FORMATION; SIROLIMUS-ELUTING STENTS; BARE-METAL; THROMBOTIC RISK; SLOW-RELEASE; IMPLANTATION; DELIVERY; HYPERSENSITIVITY; RESTENOSIS; PATHOLOGY;
D O I
10.4244/EIJY14M10_08
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The purpose of the present study was to examine the comparative vascular healing response to stents coated with permanent or biodegradable polymer and uncoated stents in a porcine model of coronary artery stenting. Methods and results: Juvenile pigs were randomly allocated to implantation of stents coated with permanent polymer (PP, methacrylate-based, n=10), biodegradable polymer (BP, poly-lactic acid-based, n=10) or bare metal control stents (n=10), in the absence of antiproliferative drugs. At 28 days, animals were sacrificed and specimens prepared for histopathologic assessment. Endothelialisation was complete in all treatment groups. Vascular injury at 28 days was greater in PP stents as compared with uncoated stents (p=0.05) though not as compared with BP-coated stents (p=ns). PP stents showed increased inflammatory scores compared with BP-coated (p=0.03) and uncoated stents (p=0.02). There was also greater neointimal growth with PP-coated stents compared with uncoated stents (p=0.02). Conclusions: In the absence of antiproliferative drugs, stents coated with methacrylate-based PP, but not with poly-lactic acid-based BP, provoked significant vessel wall inflammatory reactions resulting in greater vascular injury and increased neointimal growth compared with uncoated stents. Biodegradable polymer coatings may be considered preferable to facilitate drug elution with minimal vessel wall toxicity.
引用
收藏
页码:1020 / 1026
页数:7
相关论文
共 50 条
  • [1] Comparison of vascular response between durable and biodegradable polymer-based drug-eluting stents in a porcine coronary artery model
    Nakazawa, Gaku
    Shinke, Toshiro
    Ijichi, Takeshi
    Matsumoto, Daisuke
    Otake, Hiromasa
    Torii, Sho
    Hiranuma, Noritoshi
    Ohsue, Tsuyoshi
    Otsuka, Fumiyuki
    Shite, Junya
    Hirata, Ken-ichi
    Ikari, Yuji
    EUROINTERVENTION, 2014, 10 (06) : 717 - 723
  • [2] Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation
    Koppara, Tobias
    Joner, Michael
    Bayer, Gerd
    Steigerwald, Kristin
    Diener, Tobias
    Wittchow, Eric
    THROMBOSIS AND HAEMOSTASIS, 2012, 107 (06) : 1161 - 1171
  • [3] Comparisons of early vascular reactions in biodegradable and durable polymer-based drug-eluting stents in the porcine coronary artery
    Ijichi, Takeshi
    Nakazawa, Gaku
    Torii, Sho
    Nagamatsu, Hirofumi
    Yoshikawa, Ayako
    Souba, Junko
    Isobe, Atsushi
    Hagiwara, Hitomi
    Ikari, Yuji
    PLOS ONE, 2019, 14 (01):
  • [4] Long-Term Effects of Novel Biodegradable, Polymer-Coated, Sirolimus-Eluting Stents on Neointimal Formation in a Porcine Coronary Model
    Peng, Hong-Yu
    Chen, Ming
    Zheng, Bo
    Wang, Xin-Gang
    Huo, Yong
    INTERNATIONAL HEART JOURNAL, 2009, 50 (06) : 811 - 822
  • [5] Adventitial histopathological changes after coronary stenting in a porcine model
    Perez-Martinez, Claudia
    Perez de Prado, Armando
    Caballero-Manso, Vanesa
    Regueiro-Purrinos, Marta
    de Garnica Garcia, Ma Gracia
    Cuellas-Ramon, Carlos
    Manuel Gonzalo-Orden, Jose
    Lopez-Benito, Maria
    Altonaga, Jose R.
    Benito-Gomez, Tomas
    Fernandez-Vazquez, Felipe
    VETERINARNI MEDICINA, 2020, 65 (11) : 465 - 472
  • [6] A Review of the Ultrathin Orsiro Biodegradable Polymer Drug-eluting Stent in the Treatment of Coronary Artery Disease
    Wu, James J.
    Way, Joshua A. H.
    Brieger, David
    HEART INTERNATIONAL, 2019, 13 (02): : 17 - 24
  • [7] Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries
    Buszman, Pawel
    Milewski, Krzysztof
    Zurakowski, Aleksander
    Pajak, Jacek
    Liszka, Lukasz
    Buszman, Piotr
    Musiol, Ewa
    AbuSamra, Motaz
    Trznadel, Stanislaw
    Kaluza, Grzegorz
    KARDIOLOGIA POLSKA, 2010, 68 (05) : 503 - 509
  • [8] Peri-interventional Triple Therapy With Dabigatran Improves Vasomotion and Promotes Endothelialization in Porcine Coronary Stenting Model
    Hemetsberger, Rayyan
    Farhan, Serdar
    Lukovic, Dominika
    Zlabinger, Katrin
    Hajagos-Toth, Judit
    Bota, Judit
    Garcia-Garcia, Hector M.
    Ay, Cihan
    Samaha, Eslam
    Gaspar, Robert
    Garamvolgyi, Rita
    Huber, Kurt
    Gyongyosi, Mariann
    Spannbauer, Andreas
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [9] Mid-Term Outcomes of Novel Covered Stent with Biodegradable Membrane in Porcine Coronary Artery Perforation
    Cai, Wei
    Chen, En
    Zheng, Hong
    Hu, Danqing
    Wu, Lingzhen
    Zeng, Xiaoling
    Huang, Jinhua
    Chen, Lianglong
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (07)
  • [10] Biodegradable-Polymer Versus Polymer-Free Drug-Eluting Stents for the Treatment of Coronary Artery Disease
    Nogic, Jason
    Thein, Paul
    Mirzaee, Sam
    Comella, Andrea
    Soon, Kean
    Cameron, James D.
    West, Nick E. J.
    Brown, Adam J.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2019, 20 (10) : 865 - 870