Kinematic Impact of Anteromedial and Posterolateral Bundle Graft Fixation Angles on Double-Bundle Anterior Cruciate Ligament Reconstructions

被引:36
作者
Anderson, Colin J. [1 ]
Westerhaus, Benjamin D. [1 ]
Pietrini, Sean D. [1 ]
Ziegler, Connor G. [1 ]
Wijdicks, Coen A.
Johansen, Steinar [2 ]
Engebretsen, Lars [2 ]
LaPrade, Robert F. [3 ]
机构
[1] Univ Minnesota, Dept Orthopaed Surg, Div Sports Med, Minneapolis, MN 55455 USA
[2] Univ Oslo, Oslo Univ Hosp, Dept Orthopaed, Oslo, Norway
[3] Steadman Philippon Res Inst, Steadman Clin, Biomech Dept, Vail, CO 81657 USA
关键词
anterior cruciate ligament (ACL); double-bundle ACL reconstruction; anteromedial and posterolateral graft fixation angles; joint overconstraint; ANATOMIC DOUBLE-BUNDLE; HAMSTRING TENDON GRAFTS; KNEE FLEXION ANGLES; IN-SITU FORCES; ACL RECONSTRUCTION; BIOMECHANICAL ANALYSIS; TIBIAL LOADS; SINGLE; TENSION; STABILITY;
D O I
10.1177/0363546510364841
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Currently in double-bundle anterior cruciate ligament (ACL) reconstructions, the range of knee flexion angles that surgeons use for anteromedial (AM) and posterolateral (PL) bundle graft fixation spans from 0 degrees to 90 degrees for both bundle grafts. Despite the recent popularity of this procedure, no consensus exists on an optimal set of AM and PL graft fixation angles. Hypothesis: Graft fixation angles that simulate the native tensioning relationship of the AM and PL bundles will produce kinematic results similar to the intact knee, while graft fixation angles that do not simulate this relationship will under- or overconstrain the knee. Study design: Controlled laboratory study. Methods: Twelve cadaveric knees were biomechanically tested in the intact state, ACL-sectioned state, and a randomized order of 7 double-bundle ACL reconstructed states at multiple graft fixation angle combinations. For each test state, data were collected for 88 N anterior tibial loads, 10 N.m valgus torques, 5 N.m internal rotation torques, and 2 simulated pivot shift loads consisting of a 5 N.m internal rotation torque coupled with either a 10 N.m valgus torque or an 88 N anterior tibial load at 0 degrees, 20 degrees, 30 degrees, 60 degrees, and 90 degrees of knee flexion. Results: The AM and PL graft fixation angle combinations of 0 degrees/0 degrees (AM graft fixation angle/PL graft fixation angle), 60 degrees/0 degrees, 45 degrees/15 degrees, and 75 degrees/15 degrees restored normal laxity to the reconstructed knee in all of the biomechanical tests. The 30 degrees/30 degrees, 60 degrees/60 degrees, and 90 degrees/90 degrees graft fixation angle combinations significantly restricted knee laxity compared with the intact state in various biomechanical tests. Conclusion: We found that as long as the PL bundle graft was fixed between 0 degrees and 15 degrees, the AM graft could be fixed up to 75 degrees without restricting knee laxity. However, fixation of the PL graft at 30 degrees of knee flexion and above significantly overconstrained the knee. Clinical Relevance: This study provides a range of angles that can be used in double-bundle ACL reconstructions to restore normal knee stability without causing overconstraint.
引用
收藏
页码:1575 / 1583
页数:9
相关论文
共 47 条
[1]   APPLICATION OF A MAGNETIC TRACKING DEVICE TO KINESIOLOGIC STUDIES [J].
AN, KN ;
JACOBSEN, MC ;
BERGLUND, LJ ;
CHAO, EYS .
JOURNAL OF BIOMECHANICS, 1988, 21 (07) :613-&
[2]  
Andersen H N, 1994, Knee Surg Sports Traumatol Arthrosc, V2, P192, DOI 10.1007/BF01845586
[3]   Anatomic reconstruction of the anterior Cruciate ligament using double-bundle hamstring tendons: Surgical techniques, clinical outcomes, and complications [J].
Asagumo, Hiroto ;
Kimura, Masashi ;
Kobayashi, Yasukazu ;
Taki, Masanori ;
Takagishi, Kenji .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (06) :602-609
[4]   Strain pattern comparison of double- and single-bundle anterior Cruciate ligament reconstruction techniques with the native anterior cruciate ligament [J].
Belisle, Adelle L. ;
Bicos, James ;
Geaney, Lauren ;
Andersen, Matthew H. ;
Obopilwe, Elifho ;
Rincon, Lina ;
Nyland, John ;
Morgan, Craig ;
Caborn, David N. M. ;
Arciero, Robert A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (11) :1210-1217
[5]   Anatomic double-bundle anterior cruciate ligament reconstruction [J].
Buoncristiani, Anthony M. ;
Tjoumakaris, Fotios P. ;
Starman, James S. ;
Ferretti, Mario ;
Fu, Freddie H. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (09) :1000-1006
[6]   Biomechanical analysis of an isolated fibular (lateral) collateral ligament reconstruction using an autogenous semitendinosus graft [J].
Coobs, Benjamin R. ;
LaPrade, Robert F. ;
Griffith, Chad J. ;
Nelson, Bradley J. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (09) :1521-1527
[7]   An In Vitro Analysis of an Anatomical Medial Knee Reconstruction [J].
Coobs, Benjamin R. ;
Wijdicks, Coen A. ;
Armitage, Bryan M. ;
Spiridonov, Stanislav I. ;
Westerhaus, Benjamin D. ;
Johansen, Steinar ;
Engebretsen, Lars ;
LaPrade, Robert F. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (02) :339-347
[8]   Anatomic double bundle ACL reconstruction: a literature review [J].
Crawford, Charles ;
Nyland, John ;
Landes, Sarah ;
Jackson, Richard ;
Chang, Haw Chong ;
Nawab, Akbar ;
Caborn, David N. M. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2007, 15 (08) :946-964
[9]   The effects of different tensioning strategies on knee laxity and graft tension after double-bundle anterior Cruciate ligament reconstruction [J].
Cuomo, Pierluigi ;
Rama, Krishna Reddi Boddu Siva ;
Bull, Anthony M. J. ;
Amis, Andrew A. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (12) :2083-2090
[10]   Comparison of viscoelastic, structural, and material properties of double-looped anterior cruciate ligament grafts made from bovine digital extensor and human hamstring tendons [J].
Donahue, TLH ;
Gregersen, C ;
Hull, ML ;
Howell, SM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (02) :162-169