An alternative method for radioactivity measurement in quantitative bone SPECT/CT imaging

被引:0
|
作者
Ishihara, Masaru [1 ]
Kato, Yasuaki [2 ]
Onoguchi, Masahisa [3 ]
Shibutani, Takayuki [3 ]
机构
[1] Hyogo Prefectural Kakogawa Med Ctr, Dept Radiol, 203 Kanno, Kakogawa, Hyogo 6758555, Japan
[2] Hyogo Prefectural Awaji Med Ctr, Dept Radiol, Sumoto, Hyogo, Japan
[3] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Dept Quantum Med Technol, Kanazawa, Ishikawa, Japan
关键词
Bone metastasis; SPECT; CT; standardized uptake value; measured value; fixed value; SCINTIGRAPHY; QUANTIFICATION; CANCER;
D O I
10.1177/00368504211028363
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
Bone scintigraphy with combined single-photon emission computed tomography (SPECT) and computed tomography (CT) has become widely used for the detection of bone metastases. However, calculation of the semi-quantitative standardized uptake value (SUV) requires measurement of the pre- and post-injection radioactivity of the radiopharmaceutical. This study aimed to compare measured and fixed input radioactivity values for quantitative SPECT/CT bone imaging to examine whether the fixed measurement method of radiopharmaceutical radioactivity could be used as an alternative method. Four different methods were used to quantify the Tc-99m hydroxymethylene diphosphonate input radioactivity: (A) measured pre- and post-injection radioactivity values; (B) measured pre-injection and fixed post-injection radioactivity values; (C) fixed pre-injection and measured post-injection radioactivity values; (D) fixed pre- and post-injection radioactivity values. All SPECT/CT acquisitions were analyzed using bone SPECT analysis software, and the semi-quantitative parameters (SUVpeak and SUVmean) were recorded and compared for each analytical method. Two semi-quantitative parameters showed significant differences between analytical methods A and B, A and D, and C and D. However, an additional subgroup analysis performed on patients whose median post-injection measured radioactivity value was <1.5 MBq showed no significant differences in parameters between all analytical methods. Measurement of the radiopharmaceutical radioactivity can be an alternative method because it reduces the volume of radioactivity post-injection. The simplified fixed measurement method of radiopharmaceutical radioactivity can be used as an alternative method in cases when measuring the radioactivity in quantitative bone SPECT/CT imaging is missed.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
    Kupitz, Dennis
    Wissel, Heiko
    Wuestemann, Jan
    Bluemel, Stephanie
    Pech, Maciej
    Amthauer, Holger
    Kreissl, Michael C.
    Grosser, Oliver S.
    EJNMMI PHYSICS, 2021, 8 (01)
  • [2] Effectiveness of quantitative bone SPECT/CT for bone metastasis diagnosis
    Ikeda, Takashi
    Kitajima, Kazuhiro
    Tsuchitani, Tatsuya
    Takahashi, Yoshiyuki
    Hama, Yasuhiko
    Kotura, Noriko
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2022, 25 (03) : 253 - 259
  • [3] Transition to Fast Whole-Body SPECT/CT Bone Imaging: An Assessment of Image Quality
    Alqahtani, Mansour
    Willowson, Kathy
    Fulton, Roger
    Constable, Chris
    Kench, Peter
    DIAGNOSTICS, 2022, 12 (12)
  • [4] Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality
    Dale L. Bailey
    Kathy P. Willowson
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 17 - 25
  • [5] Quantitative SPECT/CT: SPECT joins PET as a quantitative imaging modality
    Bailey, Dale L.
    Willowson, Kathy P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S17 - S25
  • [6] A Case of Radioactivity Concentrated in Orbital Implant in 99mTc-MDP Bone Scan and SPECT/CT
    Cai, Min
    Feng, Guisheng
    Zhang, Guangwei
    CLINICAL NUCLEAR MEDICINE, 2018, 43 (12) : E453 - E454
  • [7] Quantitative SPECT/CT Parameters in the Assessment of Transthyretin Cardiac Amyloidosis-A New Dimension of Molecular Imaging
    Gherghe, Mirela
    Lazar, Alexandra Maria
    Sterea, Maria-Carla
    Spiridon, Paula Monica
    Motas, Natalia
    Gales, Laurentia Nicoleta
    Coriu, Daniel
    Badelita, Sorina Nicoleta
    Mutuleanu, Mario-Demian
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (06)
  • [8] Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging
    Miwa, Kenta
    Nemoto, Reo
    Masuko, Hirotsugu
    Yamao, Tensho
    Kobayashi, Rinya
    Miyaji, Noriaki
    Inoue, Kosuke
    Onodera, Hiroya
    PLOS ONE, 2022, 17 (06):
  • [9] Test-retest repeatability of quantitative bone SPECT/CT
    Yamane, Tomohiko
    Fukushima, Kenji
    Shirotake, Suguru
    Nishimoto, Koshiro
    Okabe, Takashi
    Oyama, Masafumi
    Seto, Akira
    Kuji, Ichiei
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (03) : 338 - 346
  • [10] Bone metastasis imaging with SPECT/CT/MRI: A preclinical toolbox for therapy studies
    Sanches, Pedro Gomes
    Peters, Steffie
    Rossin, Raffaella
    Kaijzel, Eric L.
    Que, Ivo
    Lowik, Clemens W. G. M.
    Grull, Holger
    BONE, 2015, 75 : 62 - 71