Automatic segmentation of microcystic macular edema in OCT

被引:53
作者
Lang, Andrew [1 ]
Carass, Aaron [1 ,2 ]
Swingle, Emily K. [3 ]
Al-Louzi, Omar [4 ]
Bhargava, Pavan [4 ]
Saidha, Shiv [4 ]
Ying, Howard S. [5 ]
Calabresi, Peter A. [4 ]
Prince, Jerry L. [1 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[3] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
[4] Johns Hopkins Sch Med, Dept Neurol, Baltimore, MD 21287 USA
[5] Johns Hopkins Sch Med, Wilmer Eye Inst, Baltimore, MD 21287 USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; MULTIPLE-SCLEROSIS; IMAGES; LAYER; THICKNESS; SPECTRUM;
D O I
10.1364/BOE.6.000155
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Microcystic macular edema (MME) manifests as small, hypo-reflective cystic areas within the retina. For reasons that are still largely unknown, a small proportion of patients with multiple sclerosis (MS) develop MME-predominantly in the inner nuclear layer. These cystoid spaces, denoted pseudocysts, can be imaged using optical coherence tomography (OCT) where they appear as small, discrete, low intensity areas with high contrast to the surrounding tissue. The ability to automatically segment these pseudocysts would enable a more detailed study of MME than has been previously possible. Although larger pseudocysts often appear quite clearly in the OCT images, the multi-frame averaging performed by the Spectralis scanner adds a significant amount of variability to the appearance of smaller pseudocysts. Thus, simple segmentation methods only incorporating intensity information do not perform well. In this work, we propose to use a random forest classifier to classify the MME pixels. An assortment of both intensity and spatial features are used to aid the classification. Using a cross-validation evaluation strategy with manual delineation as ground truth, our method is able to correctly identify 79% of pseudocysts with a precision of 85%. Finally, we constructed a classifier from the output of our algorithm to distinguish clinically identified MME from non-MME subjects yielding an accuracy of 92%. (C) 2014 Optical Society of America
引用
收藏
页码:155 / 169
页数:15
相关论文
共 22 条
[1]  
Antony BJ, 2014, LECT NOTES COMPUT SC, V8673, P739, DOI 10.1007/978-3-319-10404-1_92
[2]   A combined machine-learning and graph-based framework for the segmentation of retinal surfaces in SD-OCT volumes [J].
Antony, Bhavna J. ;
Abramoff, Michael D. ;
Harper, Matthew M. ;
Jeong, Woojin ;
Sohn, Elliott H. ;
Kwon, Young H. ;
Kardon, Randy ;
Garvin, Mona K. .
BIOMEDICAL OPTICS EXPRESS, 2013, 4 (12) :2712-2728
[3]   Microcystic macular degeneration from optic neuropathy: not inflammatory, not trans-synaptic degeneration [J].
Barboni, Piero ;
Carelli, Valerio ;
Savini, Giacomo ;
Carbonelli, Michele ;
La Morgia, Chiara ;
Sadun, Alfredo A. .
BRAIN, 2013, 136
[4]   The expanding spectrum of aetiologies causing retinal microcystic macular change [J].
Bhargava, Pavan ;
Calabresi, Peter A. .
BRAIN, 2013, 136 :3212-3214
[5]   Random forests [J].
Breiman, L .
MACHINE LEARNING, 2001, 45 (01) :5-32
[6]   The Clinical Spectrum of Microcystic Macular Edema [J].
Burggraaff, Marloes C. ;
Trieu, Jennifer ;
de Vries-Knoppert, Willemien A. E. J. ;
Balk, Lisanne ;
Petzold, Axel .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (02) :952-961
[7]   Three-Dimensional Segmentation of Fluid-Associated Abnormalities in Retinal OCT: Probability Constrained Graph-Search-Graph-Cut [J].
Chen, Xinjian ;
Niemeijer, Meindert ;
Zhang, Li ;
Lee, Kyungmoo ;
Abramoff, Michael D. ;
Sonka, Milan .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) :1521-1531
[8]   Automatic segmentation of closed-contour features in ophthalmic images using graph theory and dynamic programming [J].
Chiu, Stephanie J. ;
Toth, Cynthia A. ;
Rickman, Catherine Bowes ;
Izatt, Joseph A. ;
Farsiu, Sina .
BIOMEDICAL OPTICS EXPRESS, 2012, 3 (05) :1127-1140
[9]  
Dufour PA, 2012, INT C PATT RECOG, P2067
[10]   Delineating fluid-filled region boundaries in optical coherence tomography images of the retina [J].
Fernández, DC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (08) :929-945