A regional comparison of mold spore concentrations outdoors and inside "clean" and "mold contaminated" southern California buildings

被引:41
作者
Baxter, DM
Perkins, JL
McGhee, CR
Seltzer, JM
机构
[1] Environm Anal Associates Inc, San Diego, CA 92109 USA
[2] Indoor Analyt Labs Inc, San Diego, CA USA
[3] Univ Texas, Sch Publ Hlth, Hlth Sci Ctr Houston, San Antonio, TX 78285 USA
[4] Univ Calif San Diego, Irvine Coll Med, Indoor Environm Monitoring Inc, San Diego, CA 92103 USA
关键词
mold; comparison; airborne;
D O I
10.1080/15459620590897523
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A total of 625 buildings and outdoor locations in the San Diego, California, area were monitored using the Allergenco Sampl-Air MK-3 impaction sampler or the Zefon Air-O-Cell slit bioaerosol cassette. Locations were classified by rigid criteria as clean commercial, commercial with mold growth, clean residential, residential with water staining, and residential with mold growth. In addition, coastal and inland outdoor locations were measured. Seven categories (total spores, Ascosporcs/Basidiospores, Cladosporium. Smut/Myxomycetes-like, Aspergillus/Penicillium (AS/PE), Alternaria, and Unidentified/Other) were detected frequently enough that maximum likelihood estimate techniques could be used to determine distribution parameters and, thus, treat these as continuous variables. For total counts (no nondetectables) an analysis of variance was used to examine differences in location means. For the other categories Land's confidence limits were generated and visually compared for differences among locations. For 12 other categories (Curvularia, Dreschlera, Epicoccum, Fusarium, Mildew-like, Pithomyces, Rusts, Stachybotrys, Stemphyllium, Torula, Ulocladium, and Zygomycetes-like), detection generally occurred in less than 10% of samples. These genera were treated as dichotomous (detect/nondetect) data, and Chi-square analyses differentiated between locations. For total counts, values were significantly, different on the order of clean < outdoor < moldy. There was a large difference between the moldy, and other location classes. For AS/PE, moldy location means were clearly higher than those for clean buildings and outdoors, although the clean and outdoor means could not be differentiated. For all other genera the results tend to indicate little or no ability to discriminate location. For example, there were no differences in the probabilities of detecting Stachybotrys among the various locations. In our study only total counts, usually driven by AS/PE concentrations, had value in determining whether a building is mold contaminated employing our set of rigorous location classification criteria.
引用
收藏
页码:8 / 18
页数:11
相关论文
共 15 条
[1]  
AIHA, 1996, FIELD GUID DET BIOL
[2]  
*ALL INC, 1992, OWN MAN US GUID A MK, V2
[3]  
[Anonymous], 1999, BIOAER ASS CONTR
[4]  
ATTFIELD MD, 1992, AM IND HYG ASSOC J, V53, P432, DOI 10.1202/0002-8894(1992)053<0432:EEFTBA>2.0.CO
[5]  
2
[6]  
BAXTER DM, 2001, EAA STANDARD OPERATI
[7]   Exposure estimation in the presence of nondetectable values: Another look [J].
Finkelstein, MM ;
Verma, DK .
AIHAJ, 2001, 62 (02) :195-198
[8]  
GRANT SMITH E., 1990, SAMPLING IDENTIFYING
[9]   ESTIMATION OF DESCRIPTIVE STATISTICS FOR MULTIPLY CENSORED WATER-QUALITY DATA [J].
HELSEL, DR ;
COHN, TA .
WATER RESOURCES RESEARCH, 1988, 24 (12) :1997-2004
[10]  
HEWITT P, 1997, APPL OCCUP ENV HYG, V12, P132