Which derivative from overnight oximetry best predicts symptomatic response to nasal continuous positive airway pressure in patients with obstructive sleep apnoea?

被引:16
作者
Choi, S [1 ]
Bennett, LS [1 ]
Mullins, R [1 ]
Davies, RJO [1 ]
Stradling, JR [1 ]
机构
[1] Univ Oxford, Oxford Radcliffe Trust, Churchill Hosp, Osler Chest Unit, Oxford OX3 7LJ, England
关键词
oximentry; sleep apnoea; polysomnography; sleep;
D O I
10.1053/rmed.2000.0860
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The cost and inconvenience of polysomnography for the investigation of obstructive sleep apnoea (OSA) has led to the search for simpler and cheaper alternatives. These are usually compared to an apnoea/hypopnoea index (AHI) derived from ore-nasal airflow and ribcage/abdominal effort sensors. However, AHI is not a proven gold standard for the identification of clinically important OSA. Recent work has shown that correctly analysed oximetry indices not only mimic AHI with considerable accuracy, but also predict the symptomatic response to nasal continuous positive airway pressure (nCPAP) at least as well as conventional polyisomnographic indices. This current study looks at 10 different derivatives of all-night oximeter tracings in 81 patients with OSA, and compares their ability to predict the improvement in subjective sleepiness after 6 months of nCPAP therapy. Sleep apnoea in this study was defined as a >4% SaO(2) dip rate of > 10 h(-1), and an Epworth sleepiness score (ESS) of >10 on presentation. Subjects took part in a placebo-controlled trial of nCPAP for 1 month and thereafter were all supplied with nCPAP set at an effective pressure. All night SaO(2) was sampled every 2 sec and later analysed for mean, median, mean nadir of SaO(2) dip, time below 90%, 2 and 12 sec delta index (an average measure of SaO(2) change across these two time periods), rapid resaturation index (rises in SaO(2) > 3% within 10 sec per hour), and >4, >3, and >2% dips per hour. These indices were then correlated with the change in ESS seen after 6 months on nCPAP. Median compliance for the group was 5.8 (5/95% range, 1.5-8.0) h night(-1). The two best correlates of improvement in ESS were the >4% SaO(2) dips h(-1) (Spearman's r = -0.33 P = 0.002) and the delta 12 sec index (r = -0.33, P = 0.003). Cumulative time below 90% SaO(2) was almost as good (r = -0.29, P = 0.009). The worst correlate was the >2% SaO(2) dips h(-1) (r = 0.01, not significant). This study has identified which of several analyses of overnight oximeter recordings best identify nCPAP responsive OSA. Both >4% SaO(2) dips and 12 sec delta index are equally predictive and presumably the most appropriate derivatives to calculate from overnight records of SaO(2).
引用
收藏
页码:895 / 899
页数:5
相关论文
共 24 条
[1]   Sleep on the cheap: the role of overnight oximetry in the diagnosis of sleep apnoea hypopnoea syndrome [J].
Bennett, JA ;
Kinnear, WJM .
THORAX, 1999, 54 (11) :958-959
[2]  
Bennett LS, 1999, AM J RESP CRIT CARE, V159, pA795
[3]   Sleep fragmentation indices as predictors of daytime sleepiness and nCPAP response in obstructive sleep apnea [J].
Bennett, LS ;
Langford, BA ;
Stradling, JR ;
Davies, RJO .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (03) :778-786
[4]   FACTORS IMPAIRING DAYTIME PERFORMANCE IN PATIENTS WITH SLEEP-APNEA HYPOPNEA SYNDROME [J].
CHESHIRE, K ;
ENGLEMAN, H ;
DEARY, I ;
SHAPIRO, C ;
DOUGLAS, NJ .
ARCHIVES OF INTERNAL MEDICINE, 1992, 152 (03) :538-541
[5]   Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies? [J].
Chiner, E ;
Signes-Costa, J ;
Arriero, JM ;
Marco, J ;
Fuentes, I ;
Sergado, A .
THORAX, 1999, 54 (11) :968-971
[6]  
Davies R J, 1997, Sleep Med Rev, V1, P87, DOI 10.1016/S1087-0792(97)90011-3
[7]   Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea [J].
Esnaola, S ;
Duran, J ;
InfanteRivard, C ;
Rubio, R ;
Fernandez, A .
EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (12) :2597-2605
[8]   A COMPARISON OF CLINICAL-ASSESSMENT AND HOME OXIMETRY IN THE DIAGNOSIS OF OBSTRUCTIVE SLEEP-APNEA [J].
GYULAY, S ;
OLSON, LG ;
HENSLEY, MJ ;
KING, MT ;
ALLEN, M ;
SAUNDERS, NA .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (01) :50-53
[9]   Randomised prospective parallel trial of therapeutic versus subtherapeutic nasal continuous positive airway pressure on simulated steering performance in patients with obstructive sleep apnoea [J].
Hack, M ;
Davies, RJO ;
Mullins, R ;
Choi, SJ ;
Ramdassingh-Dow, S ;
Jenkinson, C ;
Stradling, JR .
THORAX, 2000, 55 (03) :224-231
[10]   Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial [J].
Jenkinson, C ;
Davies, RJO ;
Mullins, R ;
Stradling, JR .
LANCET, 1999, 353 (9170) :2100-2105