This study proposes a modified dual-temperature CO2 transcritical refrigeration cycle, in which two cascade ejectors are applied to enhance the performance of a dual-temperature refrigeration system. The theoretical investigations with energetic and exergetic methods have been carried out, the results show that the dual-ejector cycle exhibits higher coefficient of performance (COP) and system exergy efficiency than that of the basic throttling refrigeration cycle and single ejector refrigeration cycle. In comparison with the single ejector refrigeration cycle at the given operation conditions, the proposed system improves the COP and exergy efficiency by 5.26-25.5% and 9.0-28.7%, and the pressure lift ratio of the two cascade ejectors could be improved by 6.0-12.2%. The largest exergy destruction of the proposed cycle occurs in the gas cooler, followed by the ejectors accounting for the 28.9% of the system exergy destruction rate. The performance characteristics of the double ejector cycle show its potential advantages in dual-temperature CO2 transcritical refrigeration systems. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:26 / 35
页数:10
相关论文
共 41 条
[1]   Advanced exergy analyses of an ejector expansion transcritical CO2 refrigeration system [J].
Bai, Tao ;
Yu, Jianlin ;
Yan, Gang .
ENERGY CONVERSION AND MANAGEMENT, 2016, 126 :850-861
[2]   Thermodynamics analysis of a modified dual-evaporator CO2 transcritical refrigeration cycle with two-stage ejector [J].
Bai, Tao ;
Yan, Gang ;
Yu, Jianlin .
ENERGY, 2015, 84 :325-335
[3]   A review - Status of CO2 as a low temperature refrigerant: Fundamentals and R&D opportunities [J].
Bansal, Pradeep .
APPLIED THERMAL ENGINEERING, 2012, 41 :18-29
[4]   A novel transcritical CO2 refrigeration cycle with two ejectors [J].
Cen, Jiwen ;
Liu, Pei ;
Jiang, Fangming .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (08) :2233-2239
[5]   Particular characteristics of transcritical CO2 refrigeration cycle with an ejector [J].
Deng, Jian-qiang ;
Jiang, Pei-xue ;
Lu, Tao ;
Lu, Wei .
APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) :381-388
[6]   Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R744 system operation [J].
Elbel, Stefan ;
Hrnjak, Pega .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (03) :411-422
[7]   Commercial refrigeration system using CO2 as the refrigerant [J].
Girotto, S ;
Minetto, S ;
Neksa, P .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (07) :717-723
[8]   Comparative analysis of an improved two-stage multi-inter-cooling ejector-expansion trans-critical CO2 refrigeration cycle [J].
Goodarzi, M. ;
Gheibi, A. ;
Motamedian, M. .
APPLIED THERMAL ENGINEERING, 2015, 81 :58-65
[9]   Multi-ejector concept for R-744 supermarket refrigeration [J].
Hafner, Armin ;
Foersterling, Sven ;
Banasiak, Krzysztof .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 43 :1-13
[10]   Experimental analysis of the R744 vapour compression rack equipped with the multiejector expansion work recovery module [J].
Haida, Michal ;
Banasiak, Krzysztof ;
Smolka, Jacek ;
Hafner, Armin ;
Eikevik, Trygve M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 64 :93-107