Leaf position verification during dynamic beam delivery: A comparison of three applications using electronic portal imaging

被引:39
作者
Partridge, M
Evans, PM
van Herk, M
Ploeger, LS
Budgell, GJ
James, HV
机构
[1] Inst Canc Res & Royal Marsden NHS Trust, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Netherlands Canc Inst, Antoni Van Leeuwenhoek Huis, Dept Radiotherapy, NL-1066 CX Amsterdam, Netherlands
[3] Christie Hosp NHS Trust, Manchester M20 4BX, Lancs, England
关键词
intensity-modulated beams; dynamic multileaf collimators; electronic portal imaging; treatment verification;
D O I
10.1118/1.599026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The use of a dynamic multileaf collimator (MLC) to deliver intensity-modulated beams presents a problem for conventional verification techniques. The use of electronic portal imaging to track MLC leaves during beam delivery has been shown to provide a solution to this problem. An experimental comparison of three different verification systems, each using a different electronic portal imaging technology, is presented. Two of the systems presented are commercially available imagers with in-house modifications, with the third system being an in-house built experimental system. The random and systematic errors present in each of the verifications systems an measured and presented, together with the study of the effects of varying dose rate and leaf speed on verification system performance. The performance of the three systems is demonstrated to be very similar, with an overall accuracy in comparing measured and prescribed collimator trajectories of approximately +/-1.0 mm. Systematic errors in the percentage delivered dose signal provided by the accelerator are significant and must be corrected for good performance of the current systems. It is demonstrated that, with suitable modifications, commercially available portal imaging systems can be used to verify dynamic MLC beam delivery. (C) 2000 American Association of Physicists in Medicine. [S0094-2405 (00)00607-6].
引用
收藏
页码:1601 / 1609
页数:9
相关论文
共 19 条
[1]   Testing of dynamic multileaf collimation [J].
Chui, CS ;
Spirou, S ;
LoSasso, T .
MEDICAL PHYSICS, 1996, 23 (05) :635-641
[2]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[3]  
JAMES H, 1999, RADIOTHER ONCOL, V51, pS25
[4]  
LUTZ W, 1996, P 4 INT WORKSH EL PO, P52
[5]   Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system [J].
Ma, LJ ;
Geis, PB ;
Boyer, AL .
MEDICAL PHYSICS, 1997, 24 (08) :1213-1220
[6]   1ST CLINICAL-EXPERIENCE WITH A NEWLY DEVELOPED ELECTRONIC PORTAL IMAGING DEVICE [J].
MEERTENS, H ;
VANHERK, M ;
BIJHOLD, J ;
BARTELINK, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (05) :1173-1181
[7]   Rapid portal imaging with a high-efficiency, large field-of-view detector [J].
Mosleh-Shirazi, MA ;
Evans, PM ;
Swindell, W ;
Symonds-Tayler, JRN ;
Webb, S ;
Partridge, M .
MEDICAL PHYSICS, 1998, 25 (12) :2333-2346
[8]   Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique [J].
Partridge, M ;
Evans, PM ;
Mosleh-Shirazi, A ;
Convery, D .
MEDICAL PHYSICS, 1998, 25 (10) :1872-1879
[9]   Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation [J].
Pasma, KL ;
Kroonwijk, M ;
de Boer, JCJ ;
Visser, AG ;
Heijmen, BJM .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) :2047-2060
[10]  
PLOEGER LS, 1998, P 5 INT WORKSH EL PO, P106