Percutaneous intramedullary fixation of trochanteric fractures of the femur - Clinical trial of a new hip nail

被引:12
作者
Ingman, AM [1 ]
机构
[1] Royal Adelaide Hosp, Orthopaed & Trauma Serv, Adelaide, SA 5000, Australia
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2000年 / 31卷 / 07期
关键词
D O I
10.1016/S0020-1383(00)00027-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Since 1992, we have developed an implant which can be inserted percutaneously without reaming the femoral shaft. In the final design, the intramedullary nail is 13 mm diameter proximally and 11 mm distally. The femoral head is fu;ed with two screws of 6.5 mm diameter? and there is a single 4.5 mm distal screw. The nail and screws are constructed from coldworked ISO 5832-9 stainless steel. From July 1994 to June 1997, 159 patients aged over 60 years with acute trochanteric femoral fractures were treated with these implants. Results were assessed on a functional basis of walking mobility and level of dependency. After three months, 89 patients (56%) had regained their previous level of mobility and 22 patients (16%) had died from unrelated causes. Average operating time for the first 50 patients was 38 min. Complications include screw cutout in two patients, prominent screws in four, one non-union and two persistent low grade infections. The complication rate is comparable with that of other methods of treatment. (C) 2000 Published by Elsevier Science Ltd.
引用
收藏
页码:483 / 487
页数:5
相关论文
共 11 条
[1]   GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS [J].
AUNE, AK ;
EKELAND, A ;
ODEGAARD, B ;
GROGAARD, B ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :127-130
[2]   FIXATION OF INTERTROCHANTERIC FRACTURES OF THE FEMUR - A RANDOMIZED PROSPECTIVE COMPARISON OF THE GAMMA-NAIL AND THE DYNAMIC HIP SCREW [J].
BRIDLE, SH ;
PATEL, AD ;
BIRCHER, M ;
CALVERT, PT .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (02) :330-334
[3]   COMPARISON OF DYNAMIC HIP SCREW AND GAMMA-NAIL - A PROSPECTIVE, RANDOMIZED, CONTROLLED TRIAL [J].
BUTT, MS ;
KRIKLER, SJ ;
NAFIE, S ;
ALI, MS .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (09) :615-618
[4]   A PROSPECTIVE COMPARATIVE-STUDY OF THE COMPRESSION HIP SCREW AND THE GAMMA-NAIL [J].
GOLDHAGEN, PR ;
OCONNOR, DR ;
SCHWARZE, D ;
SCHWARTZ, E .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1994, 8 (05) :367-372
[5]   THE GAMMA-NAIL FOR PERITROCHANTERIC FRACTURES [J].
HALDER, SC .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :340-344
[6]   Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures - A prospective, randomized study of one hundred patients [J].
Hardy, DCR ;
Descamps, PY ;
Krallis, P ;
Fabeck, L ;
Smets, P ;
Bertens, CL ;
Delince, PE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (05) :618-630
[7]   Intertrochanteric fractures of the femur: A randomized prospective comparison of the gamma nail and the Ambi hip screw [J].
Hoffman, CW ;
Lynskey, TG .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1996, 66 (03) :151-155
[8]   GAMMA-NAILS AND DYNAMIC HIP SCREWS FOR PERITROCHANTERIC FRACTURES - A RANDOMIZED PROSPECTIVE-STUDY IN ELDERLY PATIENTS [J].
LEUNG, KS ;
SO, WS ;
SHEN, WY ;
HUI, PW .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (03) :345-351
[9]  
Muller M.E., 1990, COMPREHENSIVE CLASSI, DOI [10.1007/978-3-642-61261-9_2, DOI 10.1007/978-3-642-61261-9_2]
[10]  
OBrien PJ, 1995, CAN J SURG, V38, P516