Evaluation of four point-of-care meters for rapid determination of blood lactate concentrations in dogs

被引:31
作者
Acierno, Mark J. [1 ]
Mitchell, Mark A. [1 ]
机构
[1] Louisiana State Univ, Sch Vet Med, Dept Vet Clin Sci, Baton Rouge, LA 70810 USA
来源
JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION | 2007年 / 230卷 / 09期
关键词
D O I
10.2460/javma.230.9.1315
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To determine whether blood lactate values determined in dogs with 4 commercially available point-of-care meters were in agreement with values determined with a critical care laboratory blood analyzer. Design-Prospective study. Animals-50 dogs evaluated for emergency treatment. Procedures-Blood samples were collected at initial evaluation and processed on 4 point-of-care meters and on a critical care laboratory blood analyzer. Results-All 4 point-of-care lactate meters generated measurements that were in agreement with the hospital's critical care analyzer. Values for agreement (bias) between the 4 point-of-care meters and the critical care analyzer were -0.652 (limits of agreement [LA], -1.958 to 0.6541), -0.670 (LA, -2.110 to 0.769), -0.096 (LA, -2.071 to 1.879), and -0.498 (LA, -2.616 to 1.620), respectively. Conclusions and Clinical Relevance-Despite its prognostic and therapeutic relevance, blood lactate measurement in dogs has been hampered by the inability to perform the test in a timely fashion. Results of the present study indicated that several handheld point-of-care lactate meters provided results that were in agreement with a laboratory critical care blood analyzer.
引用
收藏
页码:1315 / 1318
页数:4
相关论文
共 23 条
[1]   RETRACTED: Point-of-care (POC) testing of lactate in the intensive care patient - Accuracy, reliability, and costs of different measurement systems (Retracted article. See vol. 55, pg. 903, 2011) [J].
Boldt, J ;
Kumle, B ;
Suttner, S ;
Haisch, G .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) :194-199
[2]  
Bonagura JD, 1999, KIRKS CURRENT VET TH, VXIII, P112
[3]   Lactate measurements in critically ill patients with a hand-held analyser [J].
Brinkert, W ;
Rommes, JH ;
Bakker, J .
INTENSIVE CARE MEDICINE, 1999, 25 (09) :966-969
[4]  
de Papp E, 1999, J AM VET MED ASSOC, V215, P49
[5]  
GUYTON C, 1996, TXB MED PHYSL, P855
[6]   The value of blood lactate measurements in ICU: an evaluation of the role in the management of patients on haemofiltration [J].
Holloway, P ;
Benham, S ;
St John, A .
CLINICA CHIMICA ACTA, 2001, 307 (1-2) :9-13
[7]   Serum lactate and base deficit as predictors of mortality and morbidity [J].
Husain, FA ;
Martin, MJ ;
Mullenix, PS ;
Steele, SR ;
Elliott, DC .
AMERICAN JOURNAL OF SURGERY, 2003, 185 (05) :485-491
[8]   Serial lactate determinations for prediction of outcome after cardiac arrest [J].
Kliegel, A ;
Losert, H ;
Sterz, F ;
Holzer, M ;
Zeiner, A ;
Havel, C ;
Laggner, AN .
MEDICINE, 2004, 83 (05) :274-279
[9]   Serial measurement of arterial lactate concentrations as a prognostic indicator in relation to the incidence of disseminated intravascular coagulation in patients with systemic inflammatory response syndrome [J].
Kobayashi, S ;
Gando, S ;
Morimoto, Y ;
Nanzaki, S ;
Kemmotsu, O .
SURGERY TODAY, 2001, 31 (10) :853-859
[10]  
Lagutchik M. S., 1996, Journal of Veterinary Emergency & Critical Care, V6, P81, DOI 10.1111/j.1476-4431.1996.tb00036.x