Novel electrode systems for amperometric sensing. The case of titanium.

被引:0
|
作者
Terzi, F.
Pigani, L.
Zanardi, C.
Zanfrognini, B.
Ruggeri, S.
Maccaferri, G.
Seeber, R.
机构
来源
OPTICS AND PHOTONICS FOR COUNTERTERRORISM, CRIME FIGHTING, AND DEFENCE X; AND OPTICAL MATERIALS AND BIOMATERIALS IN SECURITY AND DEFENCE SYSTEMS TECHNOLOGY XI | 2014年 / 9253卷
关键词
electroanalysis; amperometric sensors; titanium; hydrogen peroxide; hypochlorite ions; gold; heavy metals determination;
D O I
10.1117/12.2073843
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
After working for years on organic materials, e.g., polythiophenes and relevant composites with metal nanoparticles, we shifted our attention to unusual metals, chosen as candidates to effective amperometric sensing on the basis of the atomic structure and crystalline properties. The present contribution aims at proposing an electrode material rarely employed in electroanalysis, namely Ti. We have experimented that the peculiar nature of Ti leads to electrochemical behavior quite different with respect to the conventional electrode materials, including those based on TiO2 (nano) particles. Our work focuses on the determination of strong oxidizing species, namely H2O2 and HClO, and noble metal ions, namely Au(III). Strong oxidizing species are commodity chemicals employed in a number of different industrial processes, in which usually high concentration levels should be monitored. The procedures proposed have been successfully applied also in complex matrices, such as detergent samples. As to Au(III) determination, it also constitutes a crucial tool in order to increase the efficiency of hydrometallurgic processes and of the recovery of precious materials from electronic waste. Ti electrodes allow the determination of dissolved Au species in the presence of other metal ions. In any cases the electrodes exhibit reproducible and repeatable electrochemical responses, even in the presence of high concentration of organic fouling species typical of bio-sorption processes.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Nonenzymatic amperometric sensing of glucose using a glassy carbon electrode modified with a nanocomposite consisting of reduced graphene oxide decorated with Cu2O nanoclusters
    Mei, Li-Ping
    Song, Pei
    Feng, Jiu-Ju
    Shen, Jia-Hui
    Wang, Wei
    Wang, Ai-Jun
    Weng, Xuexiang
    MICROCHIMICA ACTA, 2015, 182 (9-10) : 1701 - 1708
  • [32] Controllable Deposition of a Platinum Nanoparticle Ensemble on a Polyaniline/Graphene Hybrid as a Novel Electrode Material for Electrochemical Sensing
    Qiu, Jian-Ding
    Shi, Ling
    Liang, Ru-Ping
    Wang, Guo-Chong
    Xia, Xing-Hua
    CHEMISTRY-A EUROPEAN JOURNAL, 2012, 18 (25) : 7950 - 7959
  • [33] A Novel Process for the Fabrication of a Silver-Nanoparticle-Modified Electrode and Its Application in Nonenzymatic Glucose Sensing
    Jia, Mingzhe
    Wang, Tong
    Liang, Fenfen
    Hu, Jingbo
    ELECTROANALYSIS, 2012, 24 (09) : 1864 - 1868
  • [34] A novel and Disposable Amperometric Hydrazine Sensor based on Polydimethyldiallylamine Stabilized Copper(II)hexacyanoferrate Nanocubes modified Screen-printed Carbon Electrode
    Ramaraj, Sukanya
    Sakthivel, Rajalakshmi
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    Velusamy, Vijayalakshmi
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    Pandian, Kannaiyan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5567 - 5580
  • [35] A Novel H2O2 Amperometric Sensor based on Prussian Blue/Palladium Nanoparticles/Graphene Oxide Nanocomposite Modified Electrode
    Ahour, Fatemeh
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (06): : 812 - 829
  • [36] A novel nonenzymatic hydrogen peroxide amperometric sensor based on Pd@CeO2-NH2 nanocomposites modified glassy carbon electrode
    Guler, Muhammet
    Turkoglu, Vedat
    Kivrak, Arif
    Karahan, Fatih
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2018, 90 : 454 - 460
  • [37] Simple and Rapid Amperometric Monitoring of Hydrogen Peroxide at Hemoglobin-Modified Pencil Lead Electrode as a Novel Biosensor: Application to the Analysis of Honey Sample
    Mir Reza Majidi
    Mohammad Hossein Pournaghi-Azar
    Afsaneh Saadatirad
    Esmaeel Alipour
    Food Analytical Methods, 2015, 8 : 1067 - 1077
  • [38] Novel sensitive amperometric hydrogen peroxide sensor using layered hierarchical porous α-MoO3 and GO modified glass carbon electrode
    Li, Bo
    Song, Hai-Yan
    Deng, Zhao-Peng
    Huo, Li-Hua
    Gao, Shan
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 641 - 648
  • [39] Simple and Rapid Amperometric Monitoring of Hydrogen Peroxide at Hemoglobin-Modified Pencil Lead Electrode as a Novel Biosensor: Application to the Analysis of Honey Sample
    Majidi, Mir Reza
    Pournaghi-Azar, Mohammad Hossein
    Saadatirad, Afsaneh
    Alipour, Esmaeel
    FOOD ANALYTICAL METHODS, 2015, 8 (04) : 1067 - 1077
  • [40] Immobilized cobalt(II) phthalocyanine-cobalt(II) porphyrin pentamer at a glassy carbon electrode: Applications to efficient amperometric sensing of hydrogen peroxide in neutral and basic media
    Ozoemena, KI
    Zhao, ZX
    Nyokong, T
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (07) : 679 - 684