The 3-year follow-up study in a block of flats - experiences in the use of the Finnish indoor climate classification

被引:24
作者
Tuomainen, M
Tuomainen, A
Liesivuori, J
Pasanen, AL
机构
[1] Pulm Assoc Heli, FIN-00621 Helsinki, Finland
[2] Univ Kuopio, Dept Environm Sci, FIN-70211 Kuopio, Finland
[3] Finnish Inst Occupat Hlth, Kuopio, Finland
[4] Univ Kuopio, Dept Pharmacol & Toxicol, FIN-70211 Kuopio, Finland
关键词
indoor air measurements; occupancy; low-emitting materials; quality control; ventilation; costs; symptoms; perceived air quality;
D O I
10.1034/j.1600-0668.2003.00171.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor climate of two new blocks of flats was investigated. The case building was built for people with respiratory diseases by following the instructions of the Finnish Classification of Indoor Climate, Construction and Finishing Materials, while the control building was built using conventional building technology. The main indoor air parameters (temperature, relative humidity and levels of CO, CO2 , ammonia, total volatile organic compounds, total suspended particles, fungal spores, bacteria and cat, dog and house dust mite allergens) were measured in six apartments of both the buildings on five occasions during the 3-year occupancy. In addition, a questionnaire to evaluate symptoms of the occupants and their satisfaction with their home environment was conducted in connection with indoor air quality (IAQ) measurements. The levels of indoor air pollutants in the case building were, in general, lower than those in the control building. In addition, the asthmatic occupants informed that their symptoms had decreased during the occupancy in the case building. This case study showed that high IAQ is possible to reach by careful design, proper materials and equipment and on high-quality construction with reasonable additional costs. In addition, the study indicated that good IAQ can also be maintained during the occupancy, if sufficient information on factors affecting IAQ and guidance on proper use and care of equipment are available for occupants.
引用
收藏
页码:136 / 147
页数:12
相关论文
共 60 条
  • [1] School as a risk environment for children allergic to cats and a site for transfer of cat allergen to homes
    Almqvist, C
    Larsson, PH
    Egmar, AC
    Hedrén, M
    Malmberg, P
    Wickman, M
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (06) : 1012 - 1017
  • [2] NEW SAMPLER FOR THE COLLECTION, SIZING, AND ENUMERATION OF VIABLE AIRBORNE PARTICLES
    ANDERSEN, AA
    [J]. JOURNAL OF BACTERIOLOGY, 1958, 76 (05) : 471 - 484
  • [3] Andersson K, 1998, INDOOR AIR, P32
  • [4] Andersson K., 1993, The MM-questionnaires-a tool when solving indoor climate problems
  • [5] *ARB, 1997, 1006 ARB
  • [6] ASHRAE, 1999, Standard 62-1999: Ventilation for acceptable indoor air quality
  • [7] BJORCK M, 2000, P HLTH BUILD 2000 ES, V4, P479
  • [8] BLOMSTERBERG A, 1997, P HLTH BUILD IAQ 97, V3, P431
  • [9] BLUYSSEN P, 1989, P CLIMA 2000 SAR, V3, P25
  • [10] *CAN STAND ASS, 1994, Z2041994 CAN STAND A