Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms

被引:15
作者
Ong, Chloe C. H. [1 ]
Ang, Khong Wei [2 ]
Soh, Roger C. X. [3 ]
Tin, Kah Ming [2 ]
Yap, Jerome H. H. [2 ]
Lee, James C. L. [2 ,3 ]
Bragg, Christopher M. [1 ]
机构
[1] Sheffield Hallam Univ, Fac Hlth & Wellbeing, Sheffield, S Yorkshire, England
[2] Natl Canc Ctr Singapore, Div Radiat Oncol, Singapore, Singapore
[3] Nanyang Technol Univ, Sch Phys & Math Sci, Div Phys & Appl Phys, Singapore, Singapore
关键词
SBRT; AXB; AAA; Calculation algorithms; NSCLC; DOSE CALCULATION; RADIATION-THERAPY; LUNG; CANCER;
D O I
10.1016/j.meddos.2017.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
There is a concern for dose calculation in highly heterogenous environments such as the thorax region. This study compares the quality of treatment plans of peripheral non small cell lung cancer (NSCLC) stereotactic body radiation therapy (SBRT) using 2 calculation algorithms, namely, Eclipse Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB), for 3-dimensional conformal radiation therapy (3DCRT) and volumetric-modulated arc therapy (VMAT). Four-dimensional computed tomography (4DCT) data from 20 anonymized patients were studied using Varian Eclipse planning system, AXB, and MA version 10.0.28. A 3DCRT plan and a VMAT plan were generated using AAA and AXB with constant plan parameters for each patient. The prescription and dose constraints were benchmarked against Radiation Therapy Oncology Group (RTOG) 0915 protocol. Planning parameters of the plan were compared statistically using Mann-Whitney U tests. Results showed that 3DCRT and VMAT plans have a lower target coverage up to 8% when calculated using AXB as compared with AAA. The conformity index (CI) for AXB plans was 4.7% lower than AAA plans, but was closer to unity, which indicated better target conformity. AXB produced plans with global maximum doses which were, on average, 2% hotter than AAA plans. Both 3DCRT and VMAT plans were able to achieve D95%. VMAT plans were shown to be more conformal (CI = 1.01) and were at least 3.2% and 1.5% lower in terms of PTV maximum and mean dose, respectively. There was no statistically significant difference for doses received by organs at risk (OARs) regardless of calculation algorithms and treatment techniques. In general, the difference in tissue modeling for AXB and AAA algorithm is responsible for the dose distribution between the AXB and the AAA algorithms. The AXB VMAT plans could be used to benefit patients receiving peripheral NSCLC SBRT. (C) 2017 American Association of Medical Dosimetrists.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 45 条
  • [41] Comparison of dosimetric and radiobiological parameters on plans for prostate stereotactic body radiotherapy using an endorectal balloon for different dose-calculation algorithms and delivery-beam modes
    Kang, Sang-Won
    Suh, Tae-Suk
    Chung, Jin-Beom
    Eom, Keun-Yong
    Song, Changhoon
    Kim, In-Ah
    Kim, Jae-Sung
    Lee, Jeong-Woo
    Cho, Woong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (04) : 424 - 430
  • [42] Dosimetric comparison of lung stereotactic body radiotherapy treatment plans using averaged computed tomography and end-exhalation computed tomography images: Evaluation of the effect of different dose-calculation algorithms and prescription methods
    Mitsuyoshi, Takamasa
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Ueki, Nami
    Nakamura, Akira
    Iizuka, Yusuke
    Mampuya, Wambaka Ange
    Mizowaki, Takashi
    Hiraoka, Masahiro
    MEDICAL DOSIMETRY, 2016, 41 (04) : 305 - 309
  • [43] Dosimetric Comparison of Treatment Plans Computed With Finite Size Pencil Beam and Monte Carlo Algorithms Using the InCise™ Multileaf Collimator-Equipped Cyberknife® System
    Dona, Kalpani Nisansala Udeni Galpayage
    Shang, Charles
    Leventouri, Theodora
    JOURNAL OF MEDICAL PHYSICS, 2020, 45 (01) : 7 - 15
  • [44] Dosimetric comparison of AcurosBV with AAPM TG43 dose calculation formalism in cervical intraductal high-dose-rate brachytherapy using three different applicators
    Bi, Su-yan
    Chen, Zhi-jian
    Sun, Xing-ru
    Dai, Zhi-tao
    PRECISION RADIATION ONCOLOGY, 2022, 6 (03): : 234 - 242
  • [45] Is 5 mm MMLC suitable for VMAT-based lung SBRT? A dosimetric comparison with 2.5 mm HDMLC using RTOG-0813 treatment planning criteria for both conventional and high-dose flattening filter-free photon beams
    Subramanian, Shanmuga V.
    Subramani, Vellaiyan
    Swamy, Shanmugam Thirumalai
    Gandhi, Arun
    Chilukuri, Srinivas
    Kathirvel, Murugesan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 112 - 124