Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms

被引:15
|
作者
Ong, Chloe C. H. [1 ]
Ang, Khong Wei [2 ]
Soh, Roger C. X. [3 ]
Tin, Kah Ming [2 ]
Yap, Jerome H. H. [2 ]
Lee, James C. L. [2 ,3 ]
Bragg, Christopher M. [1 ]
机构
[1] Sheffield Hallam Univ, Fac Hlth & Wellbeing, Sheffield, S Yorkshire, England
[2] Natl Canc Ctr Singapore, Div Radiat Oncol, Singapore, Singapore
[3] Nanyang Technol Univ, Sch Phys & Math Sci, Div Phys & Appl Phys, Singapore, Singapore
关键词
SBRT; AXB; AAA; Calculation algorithms; NSCLC; DOSE CALCULATION; RADIATION-THERAPY; LUNG; CANCER;
D O I
10.1016/j.meddos.2017.05.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
There is a concern for dose calculation in highly heterogenous environments such as the thorax region. This study compares the quality of treatment plans of peripheral non small cell lung cancer (NSCLC) stereotactic body radiation therapy (SBRT) using 2 calculation algorithms, namely, Eclipse Anisotropic Analytical Algorithm (AAA) and Acuros External Beam (AXB), for 3-dimensional conformal radiation therapy (3DCRT) and volumetric-modulated arc therapy (VMAT). Four-dimensional computed tomography (4DCT) data from 20 anonymized patients were studied using Varian Eclipse planning system, AXB, and MA version 10.0.28. A 3DCRT plan and a VMAT plan were generated using AAA and AXB with constant plan parameters for each patient. The prescription and dose constraints were benchmarked against Radiation Therapy Oncology Group (RTOG) 0915 protocol. Planning parameters of the plan were compared statistically using Mann-Whitney U tests. Results showed that 3DCRT and VMAT plans have a lower target coverage up to 8% when calculated using AXB as compared with AAA. The conformity index (CI) for AXB plans was 4.7% lower than AAA plans, but was closer to unity, which indicated better target conformity. AXB produced plans with global maximum doses which were, on average, 2% hotter than AAA plans. Both 3DCRT and VMAT plans were able to achieve D95%. VMAT plans were shown to be more conformal (CI = 1.01) and were at least 3.2% and 1.5% lower in terms of PTV maximum and mean dose, respectively. There was no statistically significant difference for doses received by organs at risk (OARs) regardless of calculation algorithms and treatment techniques. In general, the difference in tissue modeling for AXB and AAA algorithm is responsible for the dose distribution between the AXB and the AAA algorithms. The AXB VMAT plans could be used to benefit patients receiving peripheral NSCLC SBRT. (C) 2017 American Association of Medical Dosimetrists.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 45 条
  • [31] Dosimetric effects of the acuros XB and anisotropic analytical algorithm on volumetric modulated arc therapy planning for prostate cancer using an endorectal balloon
    Koo, Taeryool
    Chung, Jin-Beom
    Eom, Keun-Yong
    Seok, Jin-Yong
    Kim, In-Ah
    Kim, Jae-Sung
    RADIATION ONCOLOGY, 2015, 10
  • [32] Clinical impact of using the deterministic patient dose calculation algorithm Acuros XB for lung stereotactic body radiation therapy
    Liu, Hong-Wei
    Nugent, Zoann
    Clayton, Ravinder
    Dunscombe, Peter
    Lau, Harold
    Khan, Rao
    ACTA ONCOLOGICA, 2014, 53 (03) : 324 - 329
  • [33] The dosimetric impact of titanium implants in spinal SBRT using four commercial treatment planning algorithms
    Liu, Chieh-Wen
    Cho, Young-Bin
    Magnelli, Anthony
    Angelov, Lilyana
    Balagamwala, Ehsan H.
    Chao, Samuel T.
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10):
  • [34] Dosimetric comparison of Acuros™ BV with AAPM TG43 dose calculation formalism in breast interstitial high-dose-rate brachytherapy with the use of metal catheters
    Sinnatamby, Mourougan
    Nagarajan, Vivekanandan
    Reddy, Sathyanarayana
    Karunanidhi, Gunaseelan
    Singhavajala, Vivekanandam
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2015, 7 (04) : 273 - 279
  • [35] GTV-based prescription in SBRT for lung lesions using advanced dose calculation algorithms
    Thomas Lacornerie
    Albert Lisbona
    Xavier Mirabel
    Eric Lartigau
    Nick Reynaert
    Radiation Oncology, 9
  • [36] Performance of dose calculation algorithms from three generations in lung SBRT: comparison with full Monte Carlo-based dose distributions
    Ojala, Jarkko J.
    Kapanen, Mika K.
    Hyodynmaa, Simo J.
    Wigren, Tuija K.
    Pitkanen, Maunu A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (02): : 4 - 18
  • [37] GTV-based prescription in SBRT for lung lesions using advanced dose calculation algorithms
    Lacornerie, Thomas
    Lisbona, Albert
    Mirabel, Xavier
    Lartigau, Eric
    Reynaert, Nick
    RADIATION ONCOLOGY, 2014, 9 : 223
  • [38] Dosimetric Influence of Acuros XB Dose-to-Medium and Dose-to-Water Reporting Modes on Carcinoma Cervix Using Intensity-Modulated Radiation Therapy and Volumetric RapidArc Technique
    Kumar, Lalit
    Bhushan, Manindra
    Kishore, Vimal
    Chowdhary, Rahul Lal
    Barik, Soumitra
    Sharma, Anurag
    Gairola, Munish
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (01) : 10 - 19
  • [39] Still equivalent for dose calculation in the Monte Carlo era? A comparison of free breathing and average intensity projection CT datasets for lung SBRT using three generations of dose calculation algorithms
    Zvolanek, Kristina
    Ma, Rongtao
    Zhou, Christina
    Liang, Xiaoying
    Wang, Shuo
    Verma, Vivek
    Zhu, Xiaofeng
    Zhang, Qinghui
    Driewer, Joseph
    Lin, Chi
    Zhen, Weining
    Wahl, Andrew
    Zhou, Su-Min
    Zheng, Dandan
    MEDICAL PHYSICS, 2017, 44 (05) : 1939 - 1947
  • [40] Comparison of five dose calculation algorithms in a heterogeneous media using design of experiment
    Vangvichith, M.
    Autret, D.
    Tiplica, T.
    Barreau, M.
    Dufreneix, S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 103 - 111