Non-invasive electrochemical immunosensor for sweat cortisol based on L-cys/AuNPs/MXene modified thread electrode

被引:108
作者
Laochai, Thidarut [1 ]
Yukird, Jutiporn [2 ]
Promphet, Nadtinan [2 ]
Qin, Jiaqian [2 ]
Chailapakul, Orawon [1 ,3 ]
Rodthongkum, Nadnudda [2 ,4 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Dept Chem, 254 Phayathai Rd, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Met & Mat Sci Res Inst, Soi Chula 12,Phayathai Rd, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Sci, Electrochem & Opt Spect Ctr Excellence EOSCE, Dept Chem, 254 Phayathai Rd, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Ctr Excellence Respons Wearable Mat, Bangkok 10330, Thailand
关键词
MXene; Gold nanoparticle; Thread-based electrochemical immunosensor; Sweat cortisol; Adrenal gland disorder; ECCRINE SWEAT; BIOSENSOR; ASSAY;
D O I
10.1016/j.bios.2022.114039
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thread-based electrochemical immunosensor is fabricated for non-invasive detection of cortisol in sweat by immobilization of anti-cortisol on L-cys/AuNPs/MXene modified conductive thread electrode. MXene and AuNPs increase the surface area of conductive thread electrode and facilitate anti-cortisol immobilization leading to enhanced sensor sensitivity. Anti-cortisol is immobilized on L-cys/AuNPs/MXene modified electrode by using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-hydroxysulfosuccinimide coupling agents. The electrochemical detection of cortisol is based on the decrease of oxidation current towards the antigen-antibody binding interaction owing to blocking of electron transfer process by cortisol. Under the optimal conditions, this immunosensor offers high sensitivity, a wide linearity of 5-180 ng mL(-1) and a detection limit of 0.54 ng mL(-1) with negligible effect from interferences. Furthermore, this immunosensor provides high reproducibility and long-term storage stability (>= 6 weeks). Ultimately, this system is successfully applied for the detection of cortisol in artificial sweat with satisfactory results. Hence, this platform might be suitable to apply as a wearable electrochemical sensor for sweat cortisol by integrating on a wristband.
引用
收藏
页数:10
相关论文
共 46 条
[21]   Thread as a Versatile Material for Low-Cost Microfluidic Diagnostics [J].
Li, Xu ;
Tian, Junfei ;
Shen, Wei .
ACS APPLIED MATERIALS & INTERFACES, 2010, 2 (01) :1-6
[22]   Tunable stringency aptamer selection and gold nanoparticle assay for detection of cortisol [J].
Martin, Jennifer A. ;
Chavez, Jorge L. ;
Chushak, Yaroslav ;
Chapleau, Richard R. ;
Hagen, Joshua ;
Kelley-Loughnane, Nancy .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (19) :4637-4647
[23]   Wearable Flexible and Stretchable Glove Biosensor for On-Site Detection of Organophosphorus Chemical Threats [J].
Mishra, Rupesh K. ;
Hubble, Lee J. ;
Martin, Aida ;
Kumar, Rajan ;
Barfidokht, Abbas ;
Kim, Jayoung ;
Musameh, Mustafa M. ;
Kyratzis, Ilias L. ;
Wang, Joseph .
ACS SENSORS, 2017, 2 (04) :553-561
[24]   A Textile Dressing for Temporal and Dosage Controlled Drug Delivery [J].
Mostafalu, Pooria ;
Kiaee, Gita ;
Giatsidis, Giorgio ;
Khalilpour, Akbar ;
Nabavinia, Mahboobeh ;
Dokmeci, Mehmet R. ;
Sonkusale, Sameer ;
Orgill, Dennis P. ;
Tamayol, Ali ;
Khademhosseini, Ali .
ADVANCED FUNCTIONAL MATERIALS, 2017, 27 (41)
[25]   A nanocomposite prepared from platinum particles, polyaniline and a Ti3C2 MXene for amperometric sensing of hydrogen peroxide and lactate [J].
Neampet, Supawat ;
Ruecha, Nipapan ;
Qin, Jiaqian ;
Wonsawat, Wanida ;
Chailapakul, Orawon ;
Rodthongkum, Nadnudda .
MICROCHIMICA ACTA, 2019, 186 (12)
[26]  
Ozgocer Tuba, 2017, J Immunoassay Immunochem, V38, P147, DOI 10.1080/15321819.2016.1230130
[27]   Textile sensors platform for the selective and simultaneous detection of chloride ion and pH in sweat [J].
Possanzini, Luca ;
Decataldo, Francesco ;
Mariani, Federica ;
Gualandi, Isacco ;
Tessarolo, Marta ;
Scavetta, Erika ;
Fraboni, Beatrice .
SCIENTIFIC REPORTS, 2020, 10 (01)
[28]   Non-invasive wearable chemical sensors in real-life applications [J].
Promphet, Nadtinan ;
Ummartyotin, Sarute ;
Ngeontae, Wittaya ;
Puthongkham, Pumidech ;
Rodthongkum, Nadnudda .
ANALYTICA CHIMICA ACTA, 2021, 1179
[29]   Cotton thread-based wearable sensor for non-invasive simultaneous diagnosis of diabetes and kidney failure [J].
Promphet, Nadtinan ;
Hinestroza, Juan P. ;
Rattanawaleedirojn, Pranee ;
Soatthiyanon, Niphaphun ;
Siralertmukul, Krisana ;
Potiyaraj, Pranut ;
Rodthongkum, Nadnudda .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 321
[30]   Impedimetric determination of cortisol using screen-printed electrode with aptamer-modified magnetic beads [J].
Pusomjit, Pannaporn ;
Teengam, Prinjaporn ;
Thepsuparungsikul, Nichanan ;
Sanongkiet, Sucharat ;
Chailapakul, Orawon .
MICROCHIMICA ACTA, 2021, 188 (02)