Tafel-analysis of the AP-CITROX decontamination technology of Inconel alloy 690

被引:1
作者
Katona, R. [1 ]
Rivonkar, A. [2 ]
Locskai, R. [1 ]
Bator, G. [3 ]
Abdelouas, A. [2 ]
Somlai, J. [3 ]
Kovacs, T. [1 ,3 ]
机构
[1] Univ Pannonia, Dept Radiochem & Radioecol, Veszprem, Hungary
[2] IMT Atlantique, Subatech Lab, Nantes, France
[3] Social Org Radioecol Cleanliness, Veszprem, Hungary
基金
欧盟地平线“2020”;
关键词
Oxide-layer; Inconel; Decontamination; PRIMARY CIRCUIT; BEHAVIOR; REACTORS;
D O I
10.1016/j.apradiso.2021.110073
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Safe, effective, cost-effective, easy feasible and low-waste decontamination technologies are fundamental importance from environmental and radiation protection aspects. In this study the effectiveness of AP-CITROX decontamination technology of Inconel alloy 690 was investigated. Non-radioactive representative metal samples were formed to test of decontamination technology and the clear-, the corroded-, the decontaminated layer were analysed electrochemically. The results indicate that the passivation step of the technology was not completed.
引用
收藏
页数:5
相关论文
共 20 条
  • [1] A STRESS-CORROSION CRACKING EVALUATION OF INCONEL 690 FOR STEAM-GENERATOR TUBING APPLICATIONS
    AIREY, GP
    VAIA, AR
    ASPDEN, RG
    [J]. NUCLEAR TECHNOLOGY, 1981, 55 (02) : 436 - 448
  • [2] Long-term trends in the corrosion state and surface properties of the stainless steel tubes of steam generators decontaminated chemically in VVER-type nuclear reactors
    Baja, B.
    Varga, K.
    Szabo, N. A.
    Nemeth, Z.
    Kadar, P.
    Oravetz, D.
    Homonnay, Z.
    Kuzmann, E.
    Schunk, J.
    Patek, G.
    [J]. CORROSION SCIENCE, 2009, 51 (12) : 2831 - 2839
  • [3] Hot corrosion behavior of Ni based Inconel 617 and Inconel 738 superalloys
    El-Awadi, G. A.
    Abdel-Samad, S.
    Elshazly, Ezzat S.
    [J]. APPLIED SURFACE SCIENCE, 2016, 378 : 224 - 230
  • [4] Behavior of stainless steels in pressurized water reactor primary circuits
    Feron, D.
    Herms, E.
    Tanguy, B.
    [J]. JOURNAL OF NUCLEAR MATERIALS, 2012, 427 (1-3) : 364 - 377
  • [5] Some observations concerning the Tafel equation and its relevance to charge transfer in corrosion
    Gileadi, E
    Kirowa-Eisner, E
    [J]. CORROSION SCIENCE, 2005, 47 (12) : 3068 - 3085
  • [6] Decontamination of concrete waste from nuclear power plant decommissioning in South Korea
    Han, Sangsoo
    Hong, Seokju
    Nam, Seongsik
    Kim, Won-Seok
    Um, Wooyong
    [J]. ANNALS OF NUCLEAR ENERGY, 2020, 149
  • [7] Effects of AP-CITROX decontamination procedure on the surface oxide layer composition of stainless steel originating from the primary circuit of a VVER-type nuclear reactor
    Homonnay, Z
    Vértes, A
    Kuzmann, E
    Varga, K
    Baradlai, P
    Hirschberg, G
    Schunk, J
    Tilky, P
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 246 (01) : 131 - 136
  • [8] Assessment of radioactive contamination in primary circuit of WWER-440 type reactors by computer code OSCAR for the decommissioning case
    Juodis, Laurynas
    Maceika, Evaldas
    Plukis, Arturas
    Dacquait, Frederic
    Genin, Jean-Baptiste
    Benier, Gilles
    [J]. PROGRESS IN NUCLEAR ENERGY, 2019, 110 : 191 - 198
  • [9] Corrosion properties of inconel 617 alloy after heat treatment at elevated temperature
    Kewther, A
    Yilbas, BS
    Hashmi, MSJ
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2001, 10 (01) : 108 - 113
  • [10] Corrosion characteristics of Ni-base superalloys in high temperature steam with and without hydrogen
    Kim, Donghoon
    Kim, Daejong
    Lee, Ho Jung
    Jang, Changheui
    Yoon, Duk Joo
    [J]. JOURNAL OF NUCLEAR MATERIALS, 2013, 441 (1-3) : 612 - 622