Selective stimulation of the human femoral nerve with a flat interface nerve electrode
被引:93
作者:
Schiefer, M. A.
论文数: 0引用数: 0
h-index: 0
机构:
Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USACase Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Schiefer, M. A.
[1
]
Polasek, K. H.
论文数: 0引用数: 0
h-index: 0
机构:
Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USACase Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Polasek, K. H.
[1
]
Triolo, R. J.
论文数: 0引用数: 0
h-index: 0
机构:
Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Louis Stokes Cleveland Dept Vet Affairs Med Ctr, Cleveland, OH USA
Case Western Reserve Univ, Dept Orthopaed, Cleveland, OH 44106 USACase Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Triolo, R. J.
[1
,2
,3
]
Pinault, G. C. J.
论文数: 0引用数: 0
h-index: 0
机构:
Louis Stokes Cleveland Dept Vet Affairs Med Ctr, Cleveland, OH USACase Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Pinault, G. C. J.
[2
]
Tyler, D. J.
论文数: 0引用数: 0
h-index: 0
机构:
Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Louis Stokes Cleveland Dept Vet Affairs Med Ctr, Cleveland, OH USACase Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
Tyler, D. J.
[1
,2
]
机构:
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Louis Stokes Cleveland Dept Vet Affairs Med Ctr, Cleveland, OH USA
[3] Case Western Reserve Univ, Dept Orthopaed, Cleveland, OH 44106 USA
SPINAL-CORD-INJURY;
CAT SCIATIC-NERVE;
HUMAN LOWER-LIMB;
ELECTRICAL-STIMULATION;
CUFF ELECTRODES;
INTRAFASCICULAR ELECTRODES;
MOTOR FASCICLES;
LOWER-EXTREMITY;
ACTIVATION;
GAIT;
D O I:
10.1088/1741-2560/7/2/026006
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
In humans, we tested the hypothesis that a flat interface nerve electrode (FINE) placed around the femoral nerve trunk can selectively stimulate each muscle the nerve innervates. In a series of intraoperative trials during routine vascular surgeries, an eight-contact FINE was placed around the femoral nerve between the inguinal ligament and the first nerve branching point. The capability of the FINE to selectively recruit muscles innervated by the femoral nerve was assessed with electromyograms (EMGs) of the twitch responses to electrical stimulation. At least four of the six muscles innervated by the femoral nerve were independently and selectively recruited in all subjects. Of these, at least one muscle was a hip flexor and at least two were knee extensors. Results from the intraoperative experiments were used to estimate the potential for the electrode to restore knee extension and hip flexion through functional electrical stimulation. Normalized EMGs and biomechanical simulations were used to estimate joint moments and functional efficacy. Estimated knee extension moments exceed the threshold required for the sit-to-stand transition.
机构:
Univ Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USAUniv Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USA
Branner, A
Normann, RA
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USAUniv Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USA
机构:
Univ Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USAUniv Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USA
Branner, A
Normann, RA
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USAUniv Utah, Dept Bioengn, Ctr Neural Interfaces, Salt Lake City, UT 84112 USA