Impact of experience with a retrograde-viewing device on adenoma detection rates and withdrawal times during colonoscopy: the Third Eye Retroscope study group

被引:94
作者
DeMarco, Daniel C. [1 ]
Odstrcil, Elizabeth
Lara, Luis F.
Bass, David [2 ]
Herdman, Chase [3 ]
Kinney, Timothy [4 ]
Gupta, Kapil [4 ]
Wolf, Leon [5 ]
Dewar, Thomas [3 ]
Deas, Thomas M. [3 ]
Mehta, Manoj K. [6 ]
Anwer, M. Badar [7 ]
Pellish, Randall [8 ]
Hamilton, J. Kent
Polter, Daniel
Reddy, K. Gautham [9 ]
Hanan, Ira [9 ]
机构
[1] Baylor Univ, Med Ctr, Digest Hlth Associates Texas, Dallas, TX 75246 USA
[2] N Hills Hosp, Richland Hills, TX USA
[3] SW Ft Worth Endoscopy Ctr, Ft Worth, TX USA
[4] Hennepin Cty Med Ctr, Minneapolis, MN 55415 USA
[5] Univ Texas SW, Dallas, TX USA
[6] N Shore Univ Hlth Syst, Evanston, IL USA
[7] Florida Hosp, Celebration, FL USA
[8] Univ Massachusetts, Worcester, MA 01605 USA
[9] Univ Chicago, Chicago, IL 60637 USA
关键词
SOCIETY-TASK-FORCE; COLORECTAL-CANCER; MISS RATES; AMERICAN-COLLEGE; SURVEILLANCE; QUALITY; POLYPS; GUIDELINES; YIELD;
D O I
10.1016/j.gie.2009.12.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Colonoscopy has been adopted as the preferred method to screen for colorectal neoplasia in the United States. However, lesions can be missed because of numerus factors, including location oil the proximal aspect Of folds Or flexures, where they may be difficult to detect with the forward-viewing colonoscope. The Third Eye Retroscope (TER) is a disposable device that is passed through the instrument channel of a standard colonoscope to provide a retrograde view that complements the forward view of the colonoscope during withdrawal. Objective: To evaluate whether experience with the TER affects polyp detection rates and procedure times in experienced endoscopists who had not previously used the equipment. Design, Setting, Patients: This was an open-label, prospective, multicenter study at 9 U.S. sites, involving 298 patients presenting for colonoscopy, evaluating the Use of the TER in combination with a standard colonoscope. Interventions: After cecal intubation, the TER was inserted through the instrument channel of the colonoscope During withdrawal, the forward and retrograde video images were observed simultaneously Oil a wide-screen monitor. Main Outcome Measurements: Primary outcome measures were the number and size of adenomas and all polyps detected with the standard colonoscope and with the colonoscope combined with the TER. Secondary outcome measures Were withdrawal phase time and total procedure time. Each endoscopist examined 20 subjects, divided into quartiles according to the order of their procedures, and results were compared among quartiles. Results: Overall, 182 polyps were detected with the colonoscope and 27 additional polyps with the TER, a 14.8% increase (P < .001). A total of 100 adenomas were detected with the colonoscope, and 16 more with the TER, a 16.0% increase (P < .001). For procedures performed after each endoscopist had completed 15 procedures while Using the TER, the mean additional detection rates with the TER were 17.0% for a 11 polyps (P < .001) and 25.0% for adenomas (P < .001). For lesions 6 mm or larger, the overall additional detection rates with the TER for all polyps and for adenomas were 23.2% and 24.3%, respectively. For lesions 10 mm or larger, the overall additional detection rates with the TER for all polyps and for adenomas were 22.6% and 19.0%, respectively. The mean withdrawal times in the first and fourth quartiles were 10.6 and 9.2 minutes, respectively (P = .044). Limitations: There was no randomization or separate control group. The endoscopists judged whether each lesion could have been detected with the colonscope alone by using their standard technique. Conclusions: Polyp detection rates improved significantly with the TER, especially after 15 procedures, When the mean additional detection rate for adenomas was 25.0%. Additional detection rates with the TER for medium-size and large adenomas were greater than for smaller lesions. These results suggest that, compared with a colonoscope alone, a retrograde-viewing device can increase detection rates for clinically significant adenomas without detriment to procedure time or procedure complications. (Clinical trial registration number: NCT00969124.) (Gastrointest Endosc 2010;71:542-50.)
引用
收藏
页码:542 / 550
页数:9
相关论文
共 30 条
  • [1] Colonoscopic withdrawal times and adenoma detection during screening colonoscopy
    Barclay, Robert L.
    Vicari, Joseph J.
    Doughty, Andrea S.
    Johanson, John F.
    Greenlaw, Roger L.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (24) : 2533 - 2541
  • [2] Colonoscopic miss rates for right-sided colon cancer: A population-based analysis
    Bressler, B
    Paszat, LF
    Vinden, C
    Li, C
    He, JS
    Rabeneck, L
    [J]. GASTROENTEROLOGY, 2004, 127 (02) : 452 - 456
  • [3] Screening for Colorectal Cancer: US Preventive Services Task Force Recommendation Statement
    Calonge, Ned
    Petitti, Diana B.
    DeWitt, Thomas G.
    Dietrich, Allen J.
    Gregory, Kimberly D.
    Harris, Russell
    Isham, George
    LeFevre, Michael L.
    Leipzig, Roseanne M.
    Loveland-Cherry, Carol
    Marion, Lucy N.
    Melnyk, Bernadette
    Moyer, Virginia A.
    Ockene, Judith K.
    Sawaya, George F.
    Yawn, Barbara P.
    [J]. ANNALS OF INTERNAL MEDICINE, 2008, 149 (09) : 627 - +
  • [4] Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study
    Froehlich, F
    Wietlisbach, V
    Gonvers, JJ
    Burnand, B
    Vader, JP
    [J]. GASTROINTESTINAL ENDOSCOPY, 2005, 61 (03) : 378 - 384
  • [5] Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia
    Harewood, GC
    Sharma, VK
    de Garmo, P
    [J]. GASTROINTESTINAL ENDOSCOPY, 2003, 58 (01) : 76 - 79
  • [6] Miss rate for colorectal neoplastic polyps:: a prospective multicenter study of back-to-back video colonoscopies
    Heresbach, D.
    Barrioz, T.
    Lapalus, M. G.
    Coumaros, D.
    Bauret, P.
    Potier, P.
    Sautereau, D.
    Boustiere, C.
    Grimaud, J. C.
    Barthelemy, C.
    See, J.
    Serraj, I.
    Halluin, P. N. D.
    Branger, B.
    Ponchan, T.
    [J]. ENDOSCOPY, 2008, 40 (04) : 284 - 290
  • [7] PROSPECTIVE BLINDED TRIAL OF THE COLONOSCOPIC MISS-RATE OF LARGE COLORECTAL POLYPS
    HIXSON, LJ
    FENNERTY, MB
    SAMPLINER, RE
    GAREWAL, HS
    [J]. GASTROINTESTINAL ENDOSCOPY, 1991, 37 (02) : 125 - 127
  • [8] Jemal A, 2009, CA-CANCER J CLIN, V59, P225, DOI [10.3322/caac.20006, 10.3322/caac.21387]
  • [9] Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: A joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology
    Levin, Bernard
    Lieberman, David A.
    McFarland, Beth
    Smith, Robert A.
    Brooks, Durado
    Andrews, Kimberly S.
    Dash, Chiranjeev
    Giardiello, Francis M.
    Glick, Seth
    Levin, Theodore R.
    Pickhardt, Perry
    Rex, Douglas K.
    Thorson, Alan
    Winawer, Sidney J.
    [J]. CA-A CANCER JOURNAL FOR CLINICIANS, 2008, 58 (03) : 130 - 160
  • [10] Use of colonoscopy to screen asymptomatic adults for colorectal cancer
    Lieberman, DA
    Weiss, DG
    Bond, JH
    Ahnen, DJ
    Garewal, H
    Chejfec, G
    Harford, WV
    Provenzale, D
    Sontag, S
    Schnell, T
    Campbell, DR
    Durbin, TE
    Nelson, DB
    Ewing, SL
    Triadafilopoulos, G
    Ramirez, FC
    Lee, JG
    Collins, JF
    Fennerty, B
    Johnston, TK
    Corless, CT
    McQuaid, KR
    Sampliner, RE
    Morales, TG
    Fass, R
    Smith, R
    Maheshwari, Y
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (03) : 162 - 168