High-resolution image reconstruction for PET using estimated detector response functions

被引:0
作者
Tohme, Michel S. [1 ]
Qi, Jinyi [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
来源
COMPUTATIONAL IMAGING V | 2007年 / 6498卷
关键词
Positron Emission Tomography; system modeling; detector response; iterative image reconstruction;
D O I
10.1117/12.716739
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The accuracy of the system model in an iterative reconstruction algorithm greatly affects the quality of reconstructed PET images. For efficient computation in reconstruction, the system model in PET can be factored into a product of geometric projection matrix and detector blurring matrix, where the former is often computed based on analytical calculation, and the latter is estimated using Monte Carlo simulations. In this work, we propose a method to estimate the 2D detector blurring matrix from experimental measurements. Point source data were acquired with high-count statistics in the microPET II scanner using a computer-controlled 2-D motion stage. A monotonically convergent iterative algorithm has been derived to estimate the detector blurring matrix from the point source measurements. The algorithm takes advantage of the rotational symmetry of the PET scanner with the modeling of the detector block structure. Since the resulting blurring matrix stems from actual measurements, it can take into account the physical effects in the photon detection process that are difficult or impossible to model in a Monte Carlo simulation. Reconstructed images of a line source phantom show improved resolution with the new detector blurring matrix compared to the original one from the Monte Carlo simulation. This method can be applied to other small-animal and clinical scanners.
引用
收藏
页数:8
相关论文
共 8 条
[1]   Modeling and incorporation of system response functions in 3-D whole body PET [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Lewellen, Thomas K. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :828-837
[2]   Quantitative comparison of FBP, EM, and Bayesian reconstruction algorithms for the IndyPET scanner [J].
Frese, T ;
Rouze, NC ;
Bouman, CA ;
Sauer, K ;
Hutchins, GD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (02) :258-276
[3]  
MUMCUOGLU E, 1996, IEEE NUCL SCI S MED, P1569
[4]   Fully 3-D PET reconstruction with system matrix derived from point source measurements [J].
Panin, Vladimir Y. ;
Kehren, Frank ;
Michel, Christian ;
Casey, Michael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :907-921
[5]  
QI J, 2006, P IEEE ENG MED BIOL
[6]   High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner [J].
Qi, JY ;
Leahy, RM ;
Cherry, SR ;
Chatziioannou, A ;
Farquhar, TH .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04) :1001-1013
[7]   Detector response models for statistical iterative image reconstruction in high resolution PET [J].
Selivanov, VV ;
Picard, Y ;
Cadorette, J ;
Rodrigue, S ;
Lecomte, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :1168-1175
[8]   MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging [J].
Tai, YC ;
Chatziioannou, AF ;
Yang, YF ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Newport, DF ;
Stickel, JR ;
Cherry, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (11) :1519-1537