Skin dose and dose-area product values in patients undergoing intracoronary brachytherapy

被引:11
|
作者
Vano, E [1 ]
Prieto, C
Fernandez, JM
Gonzalez, L
Sabate, M
Galvan, C
机构
[1] Univ Madrid, San Carlos Hosp, Med Phys Serv, Madrid 28040, Spain
[2] Univ Madrid, San Carlos Hosp, Intervent Cardiol Serv, Madrid 28040, Spain
[3] Univ Madrid, San Carlos Hosp, Radiothereapy Serv, Madrid 28040, Spain
[4] Univ Complutense, Sch Med, Dept Radiol, E-28040 Madrid, Spain
关键词
D O I
10.1259/bjr/33961719
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Entrance skin doses, dose-area product (DAP) values, fluoroscopy times and digital cine acquisition data were measured for 86 patients undergoing intracoronary brachytherapy procedures with beta sources, to estimate risk of skin injuries. Interventions were carried out in three dedicated X-ray interventional cardiology rooms equipped with X-ray systems operating in pulsed modes, with high filtration and edge filter options. Skin dose distribution was analysed in detail in 56 patients using slow films and thermoluminescent dosimetry. Digital recording of Digital Imaging and Communications in Medicine cine images also allowed analysis of the technical parameters used throughout the procedures. A protocol for clinical follow-up of these patients at the cardiology service is also presented, which prescribes special attention when a threshold dose is reached. Median values for DAP, fluoroscopy time and number of frames were 81.2 Gy cm(2), 17.5 min and 1569 frames, respectively, and maximum values were 323.3 Gy cm(2), 46.2 min and 3213 frames, respectively. In two cases, maximum skin doses in a procedure reached 3.5 Gy and 4.6 Gy. Comparing median values in this study, intracoronary brachytherapy involved approximately two-fold the DAP used in percutaneous transluminal coronary angioplasty procedures performed during the same period in the same catheterization laboratories, as a consequence of the need to monitor the radioactive source location used for the treatment of stenoses and the intravascular ultrasound. Special care must be paid in those cases of high dose in relation to potential patient skin injuries and late effects.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 50 条
  • [1] Skin dose and dose-area product values for interventional cardiology procedures
    Vano, E
    Gonzalez, L
    Ten, JI
    Fernandez, JM
    Guibelalde, E
    Macaya, C
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (877) : 48 - 55
  • [2] Entrance skin dose using dose-area product measurements
    Adnani, N
    MEDICAL PHYSICS, 2003, 30 (07) : 1951 - 1951
  • [3] Dose-area analysis for endovascular brachytherapy
    Ebert, M
    Boeing, N
    Geoghegan, S
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 498 - 499
  • [4] DOSE-AREA PRODUCT AND BODY DOSES
    PETOUSSIHENSS, N
    PANZER, W
    ZANKL, M
    DREXLER, G
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 363 - 366
  • [5] The dose-area product and assessment of the occupational dose in interventional radiology
    Servomaa, A
    Karppinen, J
    RADIATION PROTECTION DOSIMETRY, 2001, 96 (1-3) : 235 - 236
  • [6] Entrance skin dose using dose-area product measurements: Application to a cardiac catheterization laboratory
    Adnani, N
    MEDICAL PHYSICS, 2003, 30 (06) : 1381 - 1381
  • [7] Transition of the dose-area product to effective dose in X-ray studies of patients
    Nauchno-Prakticheskij Tsentr, Meditsinskoj Radiologii, Moscow, Russia
    Med Tekh, 3 ([d]15-17):
  • [8] Dose-area product values in frequently performed complex paediatric radiology examinations
    Ruiz, MJ
    Vano, E
    Gonzalez, L
    Fernandez, JM
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (818) : 160 - 164
  • [9] Calibration frequency of dose-area product meters
    Crawley, MT
    Mutch, S
    Nyekiova, M
    Reddy, C
    Weatherburn, H
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (879) : 259 - 261
  • [10] Dose-area product measurements in paediatric radiography
    McDonald, S
    Martin, CJ
    Darragh, CL
    Graham, DT
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (820) : 318 - 325