Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas

被引:25
作者
Chen, John Z. [1 ]
Katz, Ira M. [2 ]
Pichelin, Marine [2 ]
Zhu, Kaixian [3 ]
Caillibotte, Georges [2 ]
Noga, Michelle L. [4 ]
Finlay, Warren H. [1 ]
Martin, Andrew R. [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB, Canada
[2] Ctr Rech Paris Saclay, Air Liquide Sante Int, Med R&D, Les Loges En Josas, France
[3] Air Liquide Healthcare, Ctr Explor, Gentilly, France
[4] Univ Alberta, Radiol & Diagnost Imaging, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
long term oxygen therapy (LTOT); ambulatory oxygen; portable oxygen concentrator (POC); LOW-FLOW OXYGEN; DEPOSITION; EXERCISE; INTERSUBJECT; PERFORMANCE; ALTITUDE; DEVICES; REST;
D O I
10.2147/COPD.S141976
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Portable oxygen concentrators (POCs) typically include pulse flow (PF) modes to conserve oxygen. The primary aims of this study were to develop a predictive in vitro model for inhaled oxygen delivery using a set of realistic airway replicas, and to compare PF for a commercial POC with steady flow (SF) from a compressed oxygen cylinder. Methods: Experiments were carried out using a stationary compressed oxygen cylinder, a POC, and 15 adult nasal airway replicas based on airway geometries derived from medical images. Oxygen delivery via nasal cannula was tested at PF settings of 2.0 and 6.0, and SF rates of 2.0 and 6.0 L/min. A test lung simulated three breathing patterns representative of a chronic obstructive pulmonary disease patient at rest, during exercise, and while asleep. Volume-averaged fraction of inhaled oxygen (FiO2) was calculated by analyzing oxygen concentrations sampled at the exit of each replica and inhalation flow rates over time. POC pulse volumes were also measured using a commercial O-2 conserver test system to attempt to predict FiO2 for PF. Results: Relative volume-averaged FiO2 using PF ranged from 68% to 94% of SF values, increasing with breathing frequency and tidal volume. Three of 15 replicas failed to trigger the POC when used with the sleep breathing pattern at the 2.0 setting, and four of 15 replicas failed to trigger at the 6.0 setting. FiO2 values estimated from POC pulse characteristics followed similar trends but were lower than those derived from airway replica experiments. Conclusion: For the POC tested, PF delivered similar, though consistently lower, volume-averaged FiO2 than SF rates equivalent to nominal PF settings. Assessment of PF oxygen delivery using POC pulse characteristics alone may be insufficient; testing using airway replicas is useful in identifying possible cases of failure and may provide a better assessment of FiO2.
引用
收藏
页码:2559 / 2571
页数:13
相关论文
共 33 条
[1]   Evaluation of Oxygen Concentrators and Chemical Oxygen Generators at Altitude and Temperature Extremes [J].
Blakeman, Thomas C. ;
Rodriquez, Dario, Jr. ;
Britton, Tyler J. ;
Johannigman, Jay A. ;
Petro, Michael C. ;
Branson, Richard D. .
MILITARY MEDICINE, 2016, 181 (05) :160-168
[2]   Oxygen Requirement to Reverse Altitude-Induced Hypoxemia with Continuous Flow and Pulsed Dose Oxygen [J].
Blakeman, Thomas C. ;
Rodriquez, Dario, Jr. ;
Gerlach, Travis W. ;
Dorlac, Warren C. ;
Johannigman, Jay A. ;
Branson, Richard D. .
AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2015, 86 (04) :351-356
[3]  
Bliss Peter L, 2004, Respir Care, V49, P160
[4]   COMPARISON OF 6 OXYGEN DELIVERY SYSTEMS FOR COPD PATIENTS AT REST AND DURING EXERCISE [J].
BRAUN, SR ;
SPRATT, G ;
SCOTT, GC ;
ELLERSIECK, M .
CHEST, 1992, 102 (03) :694-698
[5]   In Vivo-In Vitro Correlations: Predicting Pulmonary Drug Deposition from Pharmaceutical Aerosols [J].
Byron, Peter R. ;
Hindle, Michael ;
Lange, Carlos F. ;
Longest, P. Worth ;
McRobbie, Donald ;
Oldham, Michael J. ;
Olsson, Bo ;
Thiel, Charles G. ;
Wachtel, Herbert ;
Finlay, Warren H. .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2010, 23 :S59-S69
[6]   DEMAND OXYGEN DELIVERY FOR PATIENTS WITH RESTRICTIVE LUNG-DISEASE [J].
CARTER, R ;
TASHKIN, D ;
DJAHED, B ;
HATHAWAY, E ;
NICOTRA, MB ;
TIEP, BL .
CHEST, 1989, 96 (06) :1307-1311
[7]  
Casaburi Richard, 2005, Respir Care, V50, P594
[8]  
Chatburn RL, 2010, RESP CARE, V55, P433
[9]   The effects of high-flow vs low-flow oxygen on exercise in advanced obstructive airways disease [J].
Chatila, W ;
Nugent, T ;
Vance, G ;
Gaughan, J ;
Criner, GJ .
CHEST, 2004, 126 (04) :1108-1115
[10]   Do sinusoidal models of respiration accurately reflect the respiratory events of patients breathing on nebulizers? [J].
Coates, AL ;
Macneish, CF ;
Allen, PD ;
Ho, SL ;
Lands, LC .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1999, 12 (04) :265-273